JUNCTEK JDS8080

Contents

JUNCTEK JDS8080 Dual Channel Signal Generator User Manual

Function/Arbitrary Waveform Signal Generator

Model: JDS8000 series

1. Product Overview

The JUNCTEK JDS8000 series function arbitrary signal generator is designed to generate a variety of waveforms including sine, square, triangle, pulse, and arbitrary waves. The JDS8080 model offers a maximum frequency of 80MHz. It integrates functions such as modulation, frequency sweep, measurement, and voltage control. The device can simultaneously display the output signal, amplitude, phase, duty cycle, and frequency.

This instrument features excellent amplitude-frequency characteristics, multi-functionality, high performance, and a cost-effective, portable design. It is an ideal choice for education, research and development, production, testing, and other industrial applications. The compact and aesthetically pleasing design includes a 2.8-inch high-resolution color LCD screen for an enhanced visual experience.

Front view of the JUNCTEK JDS8080 Signal Generator

Figure 1: Front view of the JDS8080 Signal Generator.

Annotated front and rear views of the JDS8080 Signal Generator

Figure 2: Annotated front and rear views highlighting controls and interfaces.

2. Setup

2.1 Unpacking and Inspection

Upon receiving your new JDS8000 series arbitrary function signal generator, it is recommended to inspect the instrument according to the following steps:

Inspect the Packaging

If the packaging is damaged, do not discard the damaged packaging or cushioning materials until the shipment has been thoroughly checked for completeness and has passed both electrical and mechanical tests. The consignor or carrier is responsible for any damage to the instrument resulting from shipment.

Check the Contents

Please verify the contents against the packing list. If the instrument is damaged or incomplete, contact your JUNCTEK sales representative.

Image showing the JDS8080 signal generator and its accessories

Figure 3: JDS8080 Signal Generator and included accessories.

ItemDescriptionQuantity
HostJDS8000 arbitrary function signal generator1 pc
AccessoryPower cord1 pc
USB cable1 pc
BNC to alligator clips test lead2 pc
BNC male plug test lead1 pc
Quick guide1 pc

Inspect the Instrument

In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your JUNCTEK sales representative.

2.2 Power On and Initial Setup

The JDS8080 can be powered in two ways:

  • Connect the signal generator to an AC power supply (AC85-264V, 47-63Hz) using the provided power cord.
  • Alternatively, use a DC5V±0.5V 3A power adapter.

Power-on Procedure

After correctly connecting the power supply, press the power key on the front panel to turn on the generator. The instrument will perform initialization and a self-test. Upon completion, the default interface will be displayed. If the instrument does not start normally, refer to the Troubleshooting section.

Setting the System Language

Upon first boot, you can select the desired system language using the corresponding soft key. Once set, the instrument will directly enter the main interface on subsequent power-ons without requiring language selection.

3. Operating Instructions

3.1 Front Panel Overview

The front panel of the JDS8080 features a 2.8-inch color screen, various function keys, a knob, and input/output connectors. Refer to Figure 2 for a detailed layout.

  • Power Switch: Turns the generator on/off.
  • Channel Control Keypad (CH1/CH2): Controls the output of Channel 1 and Channel 2. Pressing the button enables/disables the output and illuminates the indicator.
  • OUT Button: Simultaneously controls the output of both CH1 and CH2.
  • Signal Input Connectors (EXT.IN, MOD.IN): For external signal input (1Vpp-20Vpp) and modulation input (0Vpp-3Vpp).
  • Signal Output Connectors (CH1, CH2): BNC connectors with 50Ω±10% nominal output impedance. Output waveforms according to current configuration.
  • Arrow Keys: Used to navigate and select digits for parameter editing.
  • Knob: Increases/decreases values, switches waveforms, and acts as a confirmation key.
  • Function Shortcut Keys: Numeric keys (0-9), decimal point (.), and sign key (+/-) for parameter input.
  • MEM Key: Loads/saves parameters to memory locations (00-99).
  • InBox Key: Opens input boxes for direct numerical entry.
  • SHIFT Key: Provides help information for other keys/menus.

3.2 Rear Panel Overview

The rear panel provides essential connections and interfaces for the JDS8080. Refer to Figure 2 for a detailed layout.

  • Sync Connectors: Allows synchronization with other instruments in the same series.
  • Extension Interfaces: TTL level serial port for secondary development (GPI, GPO1, GPO2, RXD, TXD, +5V, GND).
  • USB Interface: Connects to a computer for remote control via PC software or programming.
  • DC Power Socket: DC5V±0.5V 3A input (positive inside, negative outside).
  • AC Power Socket: AC 85-264V, 47-63Hz input (max 30W, fuse 250V, T3.15A).
  • Switch: Main power switch for the unit.
  • Cooling Holes: For heat dissipation.
  • Chassis Ground: Connects to ground for electrical safety.

3.3 Display Interface

The 2.8-inch TFT color LCD screen displays the current function's menu and parameter settings. Key elements include:

  • Soft Key Menu Bar: Displays operation menus for the selected function.
  • Current Channel Output Status: Indicates ON/OFF status of channels.
  • Waveform Display: Shows the theoretical waveform of the main channel.
  • Parameters: Frequency, Amplitude, Offset, Duty Cycle, Phase. These can be adjusted using the knob, arrow keys, or direct input via the InBox key.

3.4 Outputting Basic Waveforms

The JDS8080 can output basic waveforms (Sine, Square, Triangle, Pulse) from a single channel or both simultaneously. By default, both channels output a sine waveform at 10kHz frequency and 5Vpp amplitude. Users can configure various basic waveforms.

  • Selecting Output Channel: Use the CH1 or CH2 buttons to select and enable/disable channels.
  • Selecting Waveforms: Press the [WAVE] key to access waveform selection. Use the knob or arrow keys to choose the desired waveform.
  • Setting Frequency, Amplitude, Offset, Duty Cycle, Phase: Use the corresponding soft keys, knob, arrow keys, or InBox key for precise adjustments.

3.5 Modulation Mode

The JDS8000 series supports various modulation types including AM, FM, PM, ASK, FSK, PSK, Pulse, and Burst. Modulation processes a signal source and adds it to a carrier to suit channel transmission.

Diagram illustrating various modulation types supported by JDS8000

Figure 4: JDS8000 Modulation types.

To enter modulation mode, press the [MOD] key. You can select carrier waveforms, modulation sources (internal/external), and set modulation parameters like frequency, depth, deviation, and phase.

3.6 Sweep Mode

The sweep mode allows the instrument to sweep frequency, amplitude, or duty cycle. Press the [SWEEP] key to enter this mode.

  • Sweep Channel: Select CH1 or CH2.
  • Start/Stop Parameters: Set the start and stop frequencies, amplitudes, or duty cycles.
  • Sweep Time: Adjust the duration of the sweep (0.01s to 640s).
  • Sweep Direction: Choose between increment, decrement, or round trip.
  • Sweep Mode: Select linear or logarithmic.

3.7 Voltage Control Mode (VCO)

The VCO function allows external analog voltage signals to control the frequency, amplitude, or duty cycle of the output waveform. Press the [VCO] key to enter this mode.

Diagram showing Voltage-Controlled Regulation and Sweep Function

Figure 5: Voltage-Controlled Regulation and Sweep Function.

  • VCO Channel: Select CH1 or CH2.
  • Start/Stop Parameters: Define the start and stop points for frequency, amplitude, or duty cycle.
  • Voltage Calibration: Calibrate minimum and maximum external input signal voltages (0V-5V).
  • VCO Mode: Select linear or logarithmic control.

3.8 Measurement Mode

The JDS8080 can measure various parameters of an input signal and count signal periods. Press the [MEAS] key to enter this mode.

Screenshot of the Measurement and Counter interface

Figure 6: Measurement and Counter interface.

  • Measurement Function: Measures frequency (1Hz-100MHz), period, positive/negative pulse width, and duty cycle. Input signal amplitude range: 2Vpp-20Vpp via Ext.IN.
  • Coupling Settings: Select AC or DC coupling.
  • Gate Time: Set the measurement gate time (0.001s-10s).
  • Counter Function: Real-time calculation of input signal periods (2Vpp-20Vpp).

3.9 System Settings

Press the [SYS] button to access system settings, including clear memory, sound, brightness, language, built-in waveforms, arbitrary waveforms, waveform loading mode, and system information.

  • Clear Memory: Clears stored parameters.
  • Sound/Brightness/Language: Adjust these settings as needed.
  • Waveform Settings: Configure built-in and arbitrary waveforms.
  • Synchronization: Set waveform, frequency, amplitude, offset, duty cycle, and external synchronization.
  • Firmware Upgrade: Update the device firmware.
  • Parameter Fine-adjusting: Fine-tune frequency, CH1/CH2 amplitude.
  • Power-on Automatic Output: Configure default output behavior on power-up.

3.10 PC Software Control

The JDS8080 can be controlled remotely via PC software. The software and communication protocol can be downloaded from the official website. The PC software provides an intuitive interface for controlling all functions of the instrument.

  • Software Installation: Install the JDS8000 Setup application on your computer.
  • Connection: Connect the generator to your computer via the USB interface. Identify the assigned serial port in Device Manager and connect using the software.
  • Arbitrary Waveform Editing: The PC software allows for arbitrary waveform drawing and editing, and importing/exporting CSV table data.

3.11 Mobile APP Control

The JDS8080 can also be controlled via a mobile application available for Android and iOS devices. The APP connects to the instrument via Bluetooth.

Mobile APP control interface for JDS8080

Figure 7: Mobile APP control interface.

  • APP Download: Search for "JDS8000 series signal generator" on Google Play (Android) or the Apple App Store (iOS).
  • Installation: The APP requires Android 5.0+ or iOS 9.0+ and may request location services. Ensure Bluetooth is enabled for connection.
  • Connection: Open the APP, search for the instrument via Bluetooth, and connect. The APP will display "connected" and the instrument model.
  • Functionality: The APP allows viewing all relevant data and setting all functions of the instrument remotely.

4. Maintenance and Safety

4.1 General Safety Summary

Please read the following safety precautions carefully before operating the instrument to prevent personal injury or damage. Always use the instrument as specified in this manual.

  • Use Proper Power Cord: Only use the power cord designed for this instrument and authorized for use in your country.
  • Connect the Probe Correctly: If using a probe, do not connect the ground lead to high voltage, as it shares the same potential as the instrument's ground.
  • Observe All Terminal Ratings: Check all ratings and markers on the instrument and in the manual before connecting to avoid fire or shock hazards.
  • Use Proper Over-voltage Protection: Ensure no over-voltage reaches the product to prevent electric shock.
  • Do Not Operate Without Covers: Never operate the instrument with covers or panels removed.
  • Do Not Insert Anything Into the Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
  • Avoid Circuit or Wire Exposure: Do not touch exposed components when the unit is powered on.
  • Do Not Operate With Suspected Failures: If damage is suspected, have the instrument inspected by JUNCTEK authorized personnel. All maintenance must be performed by authorized personnel.

4.2 Handling and Care

  • Handle with Caution: Handle carefully during transportation to avoid damage to keys, knobs, interfaces, and other parts.
  • Avoid Impact and Chemicals: The instrument shell is fragile. Avoid strong impacts or exposure to corrosive chemicals.
  • Operating Environment: Operate and store the instrument in a dry environment between -10°C to 50°C (operating) and -20°C to 70°C (storage).
  • No Disassembly: Do not attempt to disassemble the instrument, as this will void the warranty. There are no user-serviceable parts inside.
  • Avoid Unsafe Items: Do not place lighted candles, water-filled cups, or corrosive chemicals on the instrument surface.
  • Display Screen Care: The display screen is fragile. Avoid touching or bumping it. Clean with a soft cloth if dirty.
  • Avoid Violent Movement: Do not move the instrument violently to prevent irreparable damage to internal circuits.

4.3 Anti-static Protection

Electrostatic discharge can damage the instrument. Always test in an anti-static area if possible. Before connecting cables, briefly ground both internal and external conductors to release static electricity.

4.4 Ventilation and Cleaning

  • Provide Adequate Ventilation: Ensure proper ventilation to prevent overheating, which can damage the instrument. Regularly inspect the air outlet.
  • Keep Instrument Surfaces Clean and Dry: Maintain clean and dry surfaces to prevent dust or moisture from affecting performance.
  • Do Not Operate in Wet or Explosive Conditions: Never operate the instrument in humid or explosive environments to avoid short circuits, electric shock, or personal injury.

5. Troubleshooting

This section lists common faults and troubleshooting methods for the JDS8000 series. If you encounter an issue, follow the steps below. If the problem persists, contact JUNCTEK support and provide your instrument information (accessible via the [SYS] button).

5.1 No Display After Power On

If the power key is pressed but the signal generator remains blank with no display:

  1. Check if the power connector is properly connected.
  2. Verify the power key is fully pressed.
  3. After checking the above, restart the instrument.
  4. If the instrument still does not work, contact JUNCTEK.

5.2 Screen Too Dark

If the screen is too dark to see clearly:

  1. Check the brightness setting of the LCD screen.
  2. Press the [SYS] key to enter the system setting menu. Use the soft key to navigate to brightness and adjust the knob to set the appropriate brightness level.

5.3 No Waveform Output

If settings are correct but there is no waveform output:

  1. Check if the BNC cable is correctly connected to the corresponding CH1 or CH2 channel output connectors.
  2. Check the BNC cable for internal damage.
  3. Ensure the BNC cable is securely connected to the instrument.
  4. Verify if the indicator above the signal output connectors CH1 or CH2 is lit.
  5. If the indicator is not lit, press the corresponding key to illuminate it.
  6. After completing the above inspections, restart the instrument.
  7. If the instrument still does not work, contact JUNCTEK.

6. Specifications

Product dimensions of the JDS8080

Figure 8: Product dimensions (201.23mm x 92mm x 204mm).

FeatureSpecification
Frequency Characteristic
ModelJDS8080
Sine waveform frequency range1nHz~80MHz
Square waveform frequency range1nHz~15MHz
Triangle waveform frequency range1nHz~15MHz
Pulse waveform frequency range1nHz~10MHz
TTL digital waveform frequency range1nHz~6MHz
Arbitrary waveform frequency range1nHz~6MHz
Pulse width adjustment range20nS~4S
Rise time≤10ns
Fall time≤10ns
Frequency minimum resolution1nHz (0.000000001Hz)
Frequency accuracy±5ppm 0 to 50°C
Frequency stability±3ppm per 1 year
Waveform Characteristics
Waveform typeSine, square, triangle, pulse (duty cycle adjustable), ramp, CMOS, DC level, partial sine, half wave, full wave, ladder, noise, exponential, logarithmic, Sinker, multi audio, Lorentz, and 99 user-defined waveforms.
Wave length8192 points/channel
Sampling rate275MSa/S
Waveform vertical resolution14 bits
Harmonic suppression≥45dBc(<1MHz); ≥40dBc (1MHz~20MHz)
Total harmonic distortion<1%(20Hz~20kHz,0dBm)
Square wave and pulse wave overshoot≤5%
Duty cycle adjustment range0.01%~99.99%
Sawtooth waveform linearity≥98% (0.01Hz-10kHz)
Output Characteristics
Amplitude range of the sine waveformFrequency <1MHz: 2mVpp~25Vpp
1MHz≤Frequency<11MHz: 2mVpp~20Vpp
11MHz≤Frequency<31MHz: 2mVpp~10Vpp
31MHz≤Frequency<61MHz: 2mVpp~5Vpp
61MHz≤Frequency≤80MHz: 2mVpp~3.6Vpp
Amplitude range of square/triangle waveformsFrequency <1MHz: 2mVpp~25Vpp
1MHz≤Frequency<11MHz: 2mVpp~20Vpp
11MHz≤Frequency≤15MHz: 2mVpp~10Vpp
Amplitude resolution1mVpp
Amplitude stability± 1% ±1 mVpp (@ 1 kHz,>10 mVpp)
Amplitude flatness±1%(0.1dB)<10MHz
±2%(0.2dB)<10MHz~50MHz
±10%(0.9dB)<50MHz~70MHz
Impedance50Ω±10% (typical)
ProtectionAll signal outputs can be on within 60s under load short circuit
DC Offset
Adjustment range-9.99V~12.00V
Resolution0.01 V
Phase Characteristics
Adjustment range0~359.99°
Resolution0.01°
Measurement and Counter Function
Measurement functionFrequency, positive/negative pulse width, period, duty cycle
Coupling methodDC, AC
Gate time0.001S-10.000S
Measurement modeLow frequency, high frequency
Frequency measurement range1Hz~100MHz
Input signal amplitude range1Vpp~20Vpp
Period measurement10nS~4S
Pulse Width4S
Duty cycle measurement range0.01%~99.99%
Counter range0-4294967295
Counter methodManual
Modulation Characteristics
Modulation typeAM, FM, PM, ASK, FSK, PSK, PWM, BURST
AM Carrier waveformSine, square, ramp, arbitrary (except DC)
AM SourceInternal/External
AM Modulation waveformSine, square, ramp, noise, arbitrary
AM Depth0% to 200%
AM Modulation frequency1mHz to 1MHz
FM Carrier waveformSine, square, ramp, arbitrary (except DC)
FM Modulation frequency1mHz to 1MHz
FM Frequency deviation0.1Hz to 10kHz
PM Phase deviation0° to 360°
PM Modulation frequency1mHz to 1MHz
ASK Amplitude0% to 200%
FSK Frequency hopping0.1Hz to 80MHz
PSK Phase0° to 360°
PWM Pulse period0.02uS to 40S
PWM Pulse Width0.020uS to 4S
Burst Pulse number1-1048575
Burst Idle modeZero position, positive maximum, negative maximum
Burst Trigger sourceManual, CH2 burst, external (AC), external (DC)
General Parameters
Screen2.8 inch TFT color LCD screen
Storage locations100 groups (00 to 99)
Interface methodUSB to serial interface
Extension interfaceSerial port with TTL level
Communication rateStandard 115200bps
ProtocolCommand line protocol (open)
Power
AC Supply voltage85V-264V, 47-63Hz
AC Power consumption<30W
AC Fuse250VAC, T3.15A
DC Voltage/currentDC5V±0.5V 3A
Environment
Temperature-10°C~50°C
Humidity<80%

7. Warranty and Support

7.1 Warranty Information

The warranty period for the JDS8080 instrument is one year from the date of shipment. During this period, JUNCTEK will repair or replace the faulty instrument as deemed appropriate. If maintenance is required, please contact our after-sales service and ship the product to our company.

Conditions Not Covered by Warranty:

  • Improper operation or maintenance by the user.
  • Use of user-provided software or power interfaces.
  • Disassembly and repair of the instrument without permission.

7.2 Contact Us

If you have any questions or require assistance with this product or manual, please contact JUNCTEK:

7.3 Additional Resources

For more detailed information, including machine model and factory serial number, press the [SYS] button on the instrument.

Video: Overview of the JDS8000 series signal generator features.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.