1. Product Overview
The JUNCTEK JDS8000 series function arbitrary signal generator is designed to generate a variety of waveforms including sine, square, triangle, pulse, and arbitrary waves. The JDS8080 model offers a maximum frequency of 80MHz. It integrates functions such as modulation, frequency sweep, measurement, and voltage control. The device can simultaneously display the output signal, amplitude, phase, duty cycle, and frequency.
This instrument features excellent amplitude-frequency characteristics, multi-functionality, high performance, and a cost-effective, portable design. It is an ideal choice for education, research and development, production, testing, and other industrial applications. The compact and aesthetically pleasing design includes a 2.8-inch high-resolution color LCD screen for an enhanced visual experience.

Figure 1: Front view of the JDS8080 Signal Generator.

Figure 2: Annotated front and rear views highlighting controls and interfaces.
2. Setup
2.1 Unpacking and Inspection
Upon receiving your new JDS8000 series arbitrary function signal generator, it is recommended to inspect the instrument according to the following steps:
Inspect the Packaging
If the packaging is damaged, do not discard the damaged packaging or cushioning materials until the shipment has been thoroughly checked for completeness and has passed both electrical and mechanical tests. The consignor or carrier is responsible for any damage to the instrument resulting from shipment.
Check the Contents
Please verify the contents against the packing list. If the instrument is damaged or incomplete, contact your JUNCTEK sales representative.

Figure 3: JDS8080 Signal Generator and included accessories.
| Item | Description | Quantity |
|---|---|---|
| Host | JDS8000 arbitrary function signal generator | 1 pc |
| Accessory | Power cord | 1 pc |
| USB cable | 1 pc | |
| BNC to alligator clips test lead | 2 pc | |
| BNC male plug test lead | 1 pc | |
| Quick guide | 1 pc |
Inspect the Instrument
In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your JUNCTEK sales representative.
2.2 Power On and Initial Setup
The JDS8080 can be powered in two ways:
- Connect the signal generator to an AC power supply (AC85-264V, 47-63Hz) using the provided power cord.
- Alternatively, use a DC5V±0.5V 3A power adapter.
Power-on Procedure
After correctly connecting the power supply, press the power key on the front panel to turn on the generator. The instrument will perform initialization and a self-test. Upon completion, the default interface will be displayed. If the instrument does not start normally, refer to the Troubleshooting section.
Setting the System Language
Upon first boot, you can select the desired system language using the corresponding soft key. Once set, the instrument will directly enter the main interface on subsequent power-ons without requiring language selection.
3. Operating Instructions
3.1 Front Panel Overview
The front panel of the JDS8080 features a 2.8-inch color screen, various function keys, a knob, and input/output connectors. Refer to Figure 2 for a detailed layout.
- Power Switch: Turns the generator on/off.
- Channel Control Keypad (CH1/CH2): Controls the output of Channel 1 and Channel 2. Pressing the button enables/disables the output and illuminates the indicator.
- OUT Button: Simultaneously controls the output of both CH1 and CH2.
- Signal Input Connectors (EXT.IN, MOD.IN): For external signal input (1Vpp-20Vpp) and modulation input (0Vpp-3Vpp).
- Signal Output Connectors (CH1, CH2): BNC connectors with 50Ω±10% nominal output impedance. Output waveforms according to current configuration.
- Arrow Keys: Used to navigate and select digits for parameter editing.
- Knob: Increases/decreases values, switches waveforms, and acts as a confirmation key.
- Function Shortcut Keys: Numeric keys (0-9), decimal point (.), and sign key (+/-) for parameter input.
- MEM Key: Loads/saves parameters to memory locations (00-99).
- InBox Key: Opens input boxes for direct numerical entry.
- SHIFT Key: Provides help information for other keys/menus.
3.2 Rear Panel Overview
The rear panel provides essential connections and interfaces for the JDS8080. Refer to Figure 2 for a detailed layout.
- Sync Connectors: Allows synchronization with other instruments in the same series.
- Extension Interfaces: TTL level serial port for secondary development (GPI, GPO1, GPO2, RXD, TXD, +5V, GND).
- USB Interface: Connects to a computer for remote control via PC software or programming.
- DC Power Socket: DC5V±0.5V 3A input (positive inside, negative outside).
- AC Power Socket: AC 85-264V, 47-63Hz input (max 30W, fuse 250V, T3.15A).
- Switch: Main power switch for the unit.
- Cooling Holes: For heat dissipation.
- Chassis Ground: Connects to ground for electrical safety.
3.3 Display Interface
The 2.8-inch TFT color LCD screen displays the current function's menu and parameter settings. Key elements include:
- Soft Key Menu Bar: Displays operation menus for the selected function.
- Current Channel Output Status: Indicates ON/OFF status of channels.
- Waveform Display: Shows the theoretical waveform of the main channel.
- Parameters: Frequency, Amplitude, Offset, Duty Cycle, Phase. These can be adjusted using the knob, arrow keys, or direct input via the InBox key.
3.4 Outputting Basic Waveforms
The JDS8080 can output basic waveforms (Sine, Square, Triangle, Pulse) from a single channel or both simultaneously. By default, both channels output a sine waveform at 10kHz frequency and 5Vpp amplitude. Users can configure various basic waveforms.
- Selecting Output Channel: Use the CH1 or CH2 buttons to select and enable/disable channels.
- Selecting Waveforms: Press the [WAVE] key to access waveform selection. Use the knob or arrow keys to choose the desired waveform.
- Setting Frequency, Amplitude, Offset, Duty Cycle, Phase: Use the corresponding soft keys, knob, arrow keys, or InBox key for precise adjustments.
3.5 Modulation Mode
The JDS8000 series supports various modulation types including AM, FM, PM, ASK, FSK, PSK, Pulse, and Burst. Modulation processes a signal source and adds it to a carrier to suit channel transmission.

Figure 4: JDS8000 Modulation types.
To enter modulation mode, press the [MOD] key. You can select carrier waveforms, modulation sources (internal/external), and set modulation parameters like frequency, depth, deviation, and phase.
3.6 Sweep Mode
The sweep mode allows the instrument to sweep frequency, amplitude, or duty cycle. Press the [SWEEP] key to enter this mode.
- Sweep Channel: Select CH1 or CH2.
- Start/Stop Parameters: Set the start and stop frequencies, amplitudes, or duty cycles.
- Sweep Time: Adjust the duration of the sweep (0.01s to 640s).
- Sweep Direction: Choose between increment, decrement, or round trip.
- Sweep Mode: Select linear or logarithmic.
3.7 Voltage Control Mode (VCO)
The VCO function allows external analog voltage signals to control the frequency, amplitude, or duty cycle of the output waveform. Press the [VCO] key to enter this mode.

Figure 5: Voltage-Controlled Regulation and Sweep Function.
- VCO Channel: Select CH1 or CH2.
- Start/Stop Parameters: Define the start and stop points for frequency, amplitude, or duty cycle.
- Voltage Calibration: Calibrate minimum and maximum external input signal voltages (0V-5V).
- VCO Mode: Select linear or logarithmic control.
3.8 Measurement Mode
The JDS8080 can measure various parameters of an input signal and count signal periods. Press the [MEAS] key to enter this mode.

Figure 6: Measurement and Counter interface.
- Measurement Function: Measures frequency (1Hz-100MHz), period, positive/negative pulse width, and duty cycle. Input signal amplitude range: 2Vpp-20Vpp via Ext.IN.
- Coupling Settings: Select AC or DC coupling.
- Gate Time: Set the measurement gate time (0.001s-10s).
- Counter Function: Real-time calculation of input signal periods (2Vpp-20Vpp).
3.9 System Settings
Press the [SYS] button to access system settings, including clear memory, sound, brightness, language, built-in waveforms, arbitrary waveforms, waveform loading mode, and system information.
- Clear Memory: Clears stored parameters.
- Sound/Brightness/Language: Adjust these settings as needed.
- Waveform Settings: Configure built-in and arbitrary waveforms.
- Synchronization: Set waveform, frequency, amplitude, offset, duty cycle, and external synchronization.
- Firmware Upgrade: Update the device firmware.
- Parameter Fine-adjusting: Fine-tune frequency, CH1/CH2 amplitude.
- Power-on Automatic Output: Configure default output behavior on power-up.
3.10 PC Software Control
The JDS8080 can be controlled remotely via PC software. The software and communication protocol can be downloaded from the official website. The PC software provides an intuitive interface for controlling all functions of the instrument.
- Software Installation: Install the JDS8000 Setup application on your computer.
- Connection: Connect the generator to your computer via the USB interface. Identify the assigned serial port in Device Manager and connect using the software.
- Arbitrary Waveform Editing: The PC software allows for arbitrary waveform drawing and editing, and importing/exporting CSV table data.
3.11 Mobile APP Control
The JDS8080 can also be controlled via a mobile application available for Android and iOS devices. The APP connects to the instrument via Bluetooth.

Figure 7: Mobile APP control interface.
- APP Download: Search for "JDS8000 series signal generator" on Google Play (Android) or the Apple App Store (iOS).
- Installation: The APP requires Android 5.0+ or iOS 9.0+ and may request location services. Ensure Bluetooth is enabled for connection.
- Connection: Open the APP, search for the instrument via Bluetooth, and connect. The APP will display "connected" and the instrument model.
- Functionality: The APP allows viewing all relevant data and setting all functions of the instrument remotely.
4. Maintenance and Safety
4.1 General Safety Summary
Please read the following safety precautions carefully before operating the instrument to prevent personal injury or damage. Always use the instrument as specified in this manual.
- Use Proper Power Cord: Only use the power cord designed for this instrument and authorized for use in your country.
- Connect the Probe Correctly: If using a probe, do not connect the ground lead to high voltage, as it shares the same potential as the instrument's ground.
- Observe All Terminal Ratings: Check all ratings and markers on the instrument and in the manual before connecting to avoid fire or shock hazards.
- Use Proper Over-voltage Protection: Ensure no over-voltage reaches the product to prevent electric shock.
- Do Not Operate Without Covers: Never operate the instrument with covers or panels removed.
- Do Not Insert Anything Into the Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
- Avoid Circuit or Wire Exposure: Do not touch exposed components when the unit is powered on.
- Do Not Operate With Suspected Failures: If damage is suspected, have the instrument inspected by JUNCTEK authorized personnel. All maintenance must be performed by authorized personnel.
4.2 Handling and Care
- Handle with Caution: Handle carefully during transportation to avoid damage to keys, knobs, interfaces, and other parts.
- Avoid Impact and Chemicals: The instrument shell is fragile. Avoid strong impacts or exposure to corrosive chemicals.
- Operating Environment: Operate and store the instrument in a dry environment between -10°C to 50°C (operating) and -20°C to 70°C (storage).
- No Disassembly: Do not attempt to disassemble the instrument, as this will void the warranty. There are no user-serviceable parts inside.
- Avoid Unsafe Items: Do not place lighted candles, water-filled cups, or corrosive chemicals on the instrument surface.
- Display Screen Care: The display screen is fragile. Avoid touching or bumping it. Clean with a soft cloth if dirty.
- Avoid Violent Movement: Do not move the instrument violently to prevent irreparable damage to internal circuits.
4.3 Anti-static Protection
Electrostatic discharge can damage the instrument. Always test in an anti-static area if possible. Before connecting cables, briefly ground both internal and external conductors to release static electricity.
4.4 Ventilation and Cleaning
- Provide Adequate Ventilation: Ensure proper ventilation to prevent overheating, which can damage the instrument. Regularly inspect the air outlet.
- Keep Instrument Surfaces Clean and Dry: Maintain clean and dry surfaces to prevent dust or moisture from affecting performance.
- Do Not Operate in Wet or Explosive Conditions: Never operate the instrument in humid or explosive environments to avoid short circuits, electric shock, or personal injury.
5. Troubleshooting
This section lists common faults and troubleshooting methods for the JDS8000 series. If you encounter an issue, follow the steps below. If the problem persists, contact JUNCTEK support and provide your instrument information (accessible via the [SYS] button).
5.1 No Display After Power On
If the power key is pressed but the signal generator remains blank with no display:
- Check if the power connector is properly connected.
- Verify the power key is fully pressed.
- After checking the above, restart the instrument.
- If the instrument still does not work, contact JUNCTEK.
5.2 Screen Too Dark
If the screen is too dark to see clearly:
- Check the brightness setting of the LCD screen.
- Press the [SYS] key to enter the system setting menu. Use the soft key to navigate to brightness and adjust the knob to set the appropriate brightness level.
5.3 No Waveform Output
If settings are correct but there is no waveform output:
- Check if the BNC cable is correctly connected to the corresponding CH1 or CH2 channel output connectors.
- Check the BNC cable for internal damage.
- Ensure the BNC cable is securely connected to the instrument.
- Verify if the indicator above the signal output connectors CH1 or CH2 is lit.
- If the indicator is not lit, press the corresponding key to illuminate it.
- After completing the above inspections, restart the instrument.
- If the instrument still does not work, contact JUNCTEK.
6. Specifications
Figure 8: Product dimensions (201.23mm x 92mm x 204mm).
| Feature | Specification |
|---|---|
| Frequency Characteristic | |
| Model | JDS8080 |
| Sine waveform frequency range | 1nHz~80MHz |
| Square waveform frequency range | 1nHz~15MHz |
| Triangle waveform frequency range | 1nHz~15MHz |
| Pulse waveform frequency range | 1nHz~10MHz |
| TTL digital waveform frequency range | 1nHz~6MHz |
| Arbitrary waveform frequency range | 1nHz~6MHz |
| Pulse width adjustment range | 20nS~4S |
| Rise time | ≤10ns |
| Fall time | ≤10ns |
| Frequency minimum resolution | 1nHz (0.000000001Hz) |
| Frequency accuracy | ±5ppm 0 to 50°C |
| Frequency stability | ±3ppm per 1 year |
| Waveform Characteristics | |
| Waveform type | Sine, square, triangle, pulse (duty cycle adjustable), ramp, CMOS, DC level, partial sine, half wave, full wave, ladder, noise, exponential, logarithmic, Sinker, multi audio, Lorentz, and 99 user-defined waveforms. |
| Wave length | 8192 points/channel |
| Sampling rate | 275MSa/S |
| Waveform vertical resolution | 14 bits |
| Harmonic suppression | ≥45dBc(<1MHz); ≥40dBc (1MHz~20MHz) |
| Total harmonic distortion | <1%(20Hz~20kHz,0dBm) |
| Square wave and pulse wave overshoot | ≤5% |
| Duty cycle adjustment range | 0.01%~99.99% |
| Sawtooth waveform linearity | ≥98% (0.01Hz-10kHz) |
| Output Characteristics | |
| Amplitude range of the sine waveform | Frequency <1MHz: 2mVpp~25Vpp 1MHz≤Frequency<11MHz: 2mVpp~20Vpp 11MHz≤Frequency<31MHz: 2mVpp~10Vpp 31MHz≤Frequency<61MHz: 2mVpp~5Vpp 61MHz≤Frequency≤80MHz: 2mVpp~3.6Vpp |
| Amplitude range of square/triangle waveforms | Frequency <1MHz: 2mVpp~25Vpp 1MHz≤Frequency<11MHz: 2mVpp~20Vpp 11MHz≤Frequency≤15MHz: 2mVpp~10Vpp |
| Amplitude resolution | 1mVpp |
| Amplitude stability | ± 1% ±1 mVpp (@ 1 kHz,>10 mVpp) |
| Amplitude flatness | ±1%(0.1dB)<10MHz ±2%(0.2dB)<10MHz~50MHz ±10%(0.9dB)<50MHz~70MHz |
| Impedance | 50Ω±10% (typical) |
| Protection | All signal outputs can be on within 60s under load short circuit |
| DC Offset | |
| Adjustment range | -9.99V~12.00V |
| Resolution | 0.01 V |
| Phase Characteristics | |
| Adjustment range | 0~359.99° |
| Resolution | 0.01° |
| Measurement and Counter Function | |
| Measurement function | Frequency, positive/negative pulse width, period, duty cycle |
| Coupling method | DC, AC |
| Gate time | 0.001S-10.000S |
| Measurement mode | Low frequency, high frequency |
| Frequency measurement range | 1Hz~100MHz |
| Input signal amplitude range | 1Vpp~20Vpp |
| Period measurement | 10nS~4S |
| Pulse Width | 4S |
| Duty cycle measurement range | 0.01%~99.99% |
| Counter range | 0-4294967295 |
| Counter method | Manual |
| Modulation Characteristics | |
| Modulation type | AM, FM, PM, ASK, FSK, PSK, PWM, BURST |
| AM Carrier waveform | Sine, square, ramp, arbitrary (except DC) |
| AM Source | Internal/External |
| AM Modulation waveform | Sine, square, ramp, noise, arbitrary |
| AM Depth | 0% to 200% |
| AM Modulation frequency | 1mHz to 1MHz |
| FM Carrier waveform | Sine, square, ramp, arbitrary (except DC) |
| FM Modulation frequency | 1mHz to 1MHz |
| FM Frequency deviation | 0.1Hz to 10kHz |
| PM Phase deviation | 0° to 360° |
| PM Modulation frequency | 1mHz to 1MHz |
| ASK Amplitude | 0% to 200% |
| FSK Frequency hopping | 0.1Hz to 80MHz |
| PSK Phase | 0° to 360° |
| PWM Pulse period | 0.02uS to 40S |
| PWM Pulse Width | 0.020uS to 4S |
| Burst Pulse number | 1-1048575 |
| Burst Idle mode | Zero position, positive maximum, negative maximum |
| Burst Trigger source | Manual, CH2 burst, external (AC), external (DC) |
| General Parameters | |
| Screen | 2.8 inch TFT color LCD screen |
| Storage locations | 100 groups (00 to 99) |
| Interface method | USB to serial interface |
| Extension interface | Serial port with TTL level |
| Communication rate | Standard 115200bps |
| Protocol | Command line protocol (open) |
| Power | |
| AC Supply voltage | 85V-264V, 47-63Hz |
| AC Power consumption | <30W |
| AC Fuse | 250VAC, T3.15A |
| DC Voltage/current | DC5V±0.5V 3A |
| Environment | |
| Temperature | -10°C~50°C |
| Humidity | <80% |
7. Warranty and Support
7.1 Warranty Information
The warranty period for the JDS8080 instrument is one year from the date of shipment. During this period, JUNCTEK will repair or replace the faulty instrument as deemed appropriate. If maintenance is required, please contact our after-sales service and ship the product to our company.
Conditions Not Covered by Warranty:
- Improper operation or maintenance by the user.
- Use of user-provided software or power interfaces.
- Disassembly and repair of the instrument without permission.
7.2 Contact Us
If you have any questions or require assistance with this product or manual, please contact JUNCTEK:
- E-mail: junce@junteks.com
- Website: www.junteks.com
7.3 Additional Resources
For more detailed information, including machine model and factory serial number, press the [SYS] button on the instrument.
- User Manual (PDF): https://manuals.plus/m/309b78c8212fa19a791e84f7ea791b54ff8ee265cd09818778fe3658c966af34
- PC Software/Communication Protocol: http://68.168.132.244/jds8/Jds8enSetup2208a.exe
- Android APP: http://68.168.132.244/APP/JDS8000.apk
- iOS APP: https://apps.apple.com/cn/app/jds8000/id1640964381
- Operation Demonstration Video: https://www.youtube.com/watch?v=mtS0ixnIzL8
- Computer Software Operation Video: https://www.youtube.com/watch?v=0D6m2waPkpM&t
Video: Overview of the JDS8000 series signal generator features.