1. Product Overview
The LEFOO LF12 is a robust three-phase pressure switch designed for use with 380V electrical systems in air compressors and water pumps. It automatically regulates system pressure by cycling the motor on and off between preset upper and lower pressure limits. This model features an oil-free and silent piston mechanism, incorporating an unloading relief valve to prevent motor overload during startup.
Key features include a manual on-off twist knob for easy operation and an integrated thermal relay that automatically cuts off power to prevent motor burnout in case of overload. The switch is equipped with four ports, facilitating the connection of additional accessories such as pressure gauges and safety valves, simplifying installation and system integration.

2. Safety Information
Please read and understand all safety instructions before installation and operation to prevent injury or damage.
- High Voltage: This device operates with high voltage (above 50Vac or 75Vdc). Ensure power is disconnected before any installation, wiring, or maintenance.
- Qualified Personnel: Installation and wiring should only be performed by qualified electricians in accordance with local electrical codes.
- Overload Protection: The integrated thermal relay is designed to protect the motor from overload. Do not bypass or tamper with this safety feature. The relay will cut off motor power promptly to prevent burning when overloaded.
- Installation Environment: Ensure the installation area is free from moisture, excessive dust, and corrosive substances.
- Power Cable Installation: Always install power cables without voltage and pressure applied to the system.
3. Package Contents
Upon unpacking, please verify that all components are present and undamaged:
- LEFOO LF12 Pressure Switch Unit
- Instruction Manual (this document, and refer to the PDF for full technical details)
4. Setup
4.1. Mounting the Switch
The LF12 pressure switch features a four-port manifold style base, which simplifies the mounting of other air compressor or water pump components such as valves and gauges.
- Insert the switch body base module into the bottom plate.
- Snap the switch body base module into the bracket.
- Use the switch body base fastening screw to lock the switch body base module to the bracket with a torque of 0.4 Nm.
4.2. Electrical Connections
The LF12 pressure switch is designed for Normally Closed (NC) operation. It features G1/4 and G1/2 female threads for connections, with a total of 4 ports.

Wiring Instructions:
- Ensure all power is disconnected before wiring.
- Connect the power supply and motor to the designated terminals. The switch supports both single-phase and three-phase wiring configurations.
- For detailed wiring diagrams, including terminal assignments for single-phase and three-phase systems, please refer to the comprehensive PDF user manual available at: LEFOO LF12 Technical Manual (PDF).
5. Operating Instructions
5.1. Control Modes
The LF12 pressure switch offers two primary control modes:
- Automatic Mode: The switch automatically starts and stops the connected pump or compressor based on the preset upper and lower pressure limits.
- Manual Stop Mode: The unit can be manually stopped using the integrated on-off knob.

5.2. Pressure Setting
Adjust the pressure settings using the dedicated adjustment screws on the unit:
- Upper Pressure Setting: Rotate clockwise to increase the upper pressure limit; rotate counter-clockwise to decrease it.
- Differential Pressure Setting: Rotate clockwise to increase the pressure difference (hysteresis) between cut-in and cut-out points; rotate counter-clockwise to decrease it.
5.3. Manual On-Off Knob
The white knob on the top of the unit allows for manual control. Turn the knob to the desired position to manually switch the compressor or pump on or off.
6. Maintenance
- Regular Inspections: Periodically inspect the pressure switch for any signs of wear, damage, or loose connections. Ensure it is operating correctly and responding to pressure changes as expected.
- Thermal Relay Cooling: After the thermal relay has tripped due to an overload, allow it to cool for at least 30 minutes before attempting to restart the motor. The motor cycle frequency should not be less than 5 minutes.
- Cleaning: Keep the switch free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
7. Troubleshooting
7.1. Thermal Relay Debugging
If the thermal relay is tripping unexpectedly or not at the correct overload point, it may require adjustment:
- Adjusting Overload Current: Clockwise rotation of the adjustment screw typically reduces the overload current threshold (makes it trip at lower current), while counter-clockwise rotation increases the overload current threshold (makes it trip at higher current). Refer to the detailed diagram in the PDF manual for precise adjustment procedures.
For other issues, ensure all electrical connections are secure, the power supply is stable, and the pressure lines are not obstructed.
8. Specifications
| Attribute | Value |
|---|---|
| Model Number | LF12 |
| Brand Name | LEFOO |
| Item Type | Pressure Switch |
| Material | Plastic |
| Origin | Mainland China |
| Voltage | 380V (EU LVD: Above 50Vac or 75Vdc) |
| Current Options | 6.3A, 10A, 16A, 20A |
| Pressure Range | 1-30 Bar (Specific models: 1-6bar, 3-11bar, 6-16bar, 5-25bar, 12-35bar) |
| Pressure Differential Range | 0.7-2bar, 1.5-3.5bar, 2-7bar, 3-8bar |
| Factory Setting | 2-3bar, 6-8bar, 9-12bar, 16-20bar, 25-30bar |
| Overload Capacity | 690V, 20A |
| Connect Type | NC (Normally Closed) |
| Connector Threads | G1/4 and G1/2 Female Thread (Also available: NPT1/2+3*NPT1/4, R1/2+3*R1/4) |
| Ports | 4 ports |
| Preventing | Thermal relay |
| Application | Air compressor, water pump, air pump, piston compressor, oil-free air pump |
| Medium Temperature | -5°C to +80°C |
| Electric Shock Material | Silver alloy |
| IP Code | IP54 |
| Cable Specification | 10AWG-15AWG |
| Frequency | 50Hz/60Hz |
| Dimensions (approx.) | 110mm (L) x 71mm (W) x 100mm (H) |

9. User Tips
- Air Compressor Compatibility: Users have reported excellent performance when using this pressure switch with air compressors. Ensure the pressure and current ratings match your compressor's requirements.
- Verify Connections: Before initial operation, double-check all electrical and pressure connections to ensure they are secure and leak-free.
- Pressure Adjustment: Make small adjustments to the pressure settings and observe the system's behavior to achieve optimal performance.
10. Warranty and Support
For warranty information, technical support, or any product-related inquiries, please contact your seller or the manufacturer directly.
For the most detailed technical specifications, wiring diagrams, and performance data, please refer to the official LEFOO LF12 Technical Manual (PDF): LEFOO LF12 Technical Manual (PDF).