1. Product Overview
The Gaqqee W3001/W3002 is a versatile microcomputer temperature controller designed for precise temperature management in various industrial and domestic applications. It features a high-brightness digital display for clear readings day or night, a wide temperature control range, and high accuracy. The device is built with an ABS material shell, ensuring durability and good electrical performance, and includes reverse connection protection for enhanced safety. The sensor is replaceable via a 2P terminal, allowing for flexibility with other probes.
Key Features:
- Automatic mode operation
- Wide temperature control range (-50°C to 110°C)
- High temperature control accuracy (0.1°C)
- Reverse connection protection
- Easy installation
- High-brightness digital display
- Replaceable NTC10K waterproof probe
- Durable ABS material shell
- Multi-strand wire 300V/20A excess configuration for safe and reliable wiring
2. Specifications
| Attribute | Value |
|---|---|
| Product Name | Microcomputer temperature controller |
| Product Model | XH-W3001/XH-W3002 |
| Brand Name | Gaqqee |
| Supply Voltage | DC12V/24V AC220V |
| Temperature Measurement Range | -50℃ to 110℃ |
| Temperature Control Range | -50℃ to 110℃ |
| Temperature Control Accuracy | 0.1℃ |
| Load Power | 120W (DC12V), 240W (DC24V), 1500W (AC220V) |
| Measurement Input | NTC10K waterproof probe L=1 meter |
| Output Type | Direct output |
| Output Capacity | Max 10A |
| Installation Hole Distance | 73mm (diameter 4mm) |
| Appearance Size | 60*45*31mm |
| Origin | Mainland China |
| Use | Industrial |
| Certification | CE |
| Display Size | 1.9 Inches & Under |
| Battery Included | No |
| High-concerned chemical | None |
| Is Smart Device | No |
3. Package Contents
- Thermostat (1 unit)
4. Installation
The W3001/W3002 thermostat is constructed from a durable 1.8mm thick ABS material shell. For convenient installation and fixation, side holes are provided on both sides of the unit.
Installation Dimensions:
5. Wiring Diagrams
Ensure all wiring is performed by a qualified professional and that power is disconnected before making any connections to prevent electric shock or damage to the device.
5.1. 220V Wiring Method (XH-W3002)
5.2. 12V/24V Wiring Method (XH-W3001)
Tip: For 12V/24V W3001 power supply, you can use a transformer or a 12V/24V output DC power supply.
Note: The W3001 is a direct output device. If the output is not connected to a load, do not power on the unit to prevent potential short circuits or ignition from exposed wires.
5.3. Wiring and Setting Demonstration Video
6. Operation
6.1. XH-W3001 Instructions for Use
Set Startup Temperature:
- Press the Up button once to display the current startup temperature.
- Long press the Up button for approximately 3 seconds. The startup temperature number will flash.
- Use the Up and Down buttons to set your desired startup temperature value.
Set Stop Temperature:
- Press the Down button once to display the current stop temperature.
- Long press the Down button for approximately 3 seconds. The stop temperature number will flash.
- Use the Up and Down buttons to set your desired stop temperature value.
Restore Factory Settings:
When the device is powered on, press and hold both the Up and Down keys simultaneously. The digital display will show "888" and then automatically revert to the detection temperature, indicating that factory settings have been restored.
6.2. XH-W3002 Instructions for Use
Setup Parameter Table:
| Code | Illustrate | Set Range | Factory Settings |
|---|---|---|---|
| P0 | Start temperature | -50~110℃ | 00 |
| P1 | Stop temperature | -50~110℃ | 00 |
| P2 | Temperature correction | -10~10℃ | 0℃ |
| P3 | Delay start | 0~10 Minutes | 0 Minutes |
P0: Set Startup Temperature:
- Press the Settings button once to enter the internal menu. The default display will be "P0".
- Press the Settings button again.
- Use the Up and Down buttons to set the required startup temperature.
P1: Set Stop Temperature:
- Press the Settings button once to enter the internal menu. The digital display will be "P0".
- Press the Up or Down buttons to switch to "P1".
- Press the Settings button again.
- Use the Up and Down buttons to set the desired stop temperature.
P2: Set Temperature Correction:
- Enter the internal menu (as described for P0).
- Use the Up or Down buttons to switch to "P2".
- Press the Settings button again.
- Use the Up and Down buttons to set the required calibration temperature.
Correction Logic: If the detected temperature is 0.5°C higher than the actual temperature, set the calibration to -0.5°C. If the detected temperature is 1°C lower than the actual temperature, set the calibration to 1°C. The formula is: Detected Temperature ± Corrected Temperature = Actual Temperature.
P3: Set Delay Start:
- Enter the internal menu (as described for P0).
- Use the Up or Down buttons to switch to "P3".
- Press the Settings button again.
- Use the Up and Down buttons to set the required delay time (unit is minutes).
Delay start is typically used for compressor refrigeration. A general setting value is 3-6 minutes, depending on the compressor back pressure. If you are not controlling a compressor or do not require a delay function, you can skip this setting.
7. Maintenance
No specific maintenance instructions are provided for this device. It is recommended to keep the unit clean and free from dust. Ensure all connections remain secure.
8. Troubleshooting
No specific troubleshooting steps are provided. If the device is not functioning as expected, please re-check all wiring connections and ensure the power supply matches the model's requirements. If issues persist, refer to the official PDF manual or contact customer support.
9. User Tips
- For optimal performance, ensure proper wiring and calibration according to the instructions.
- Users have noted the device's durability and precision in maintaining desired temperatures.
- The quick delivery and value of the product have been positively highlighted by users.
10. Warranty & Support
This product comes with a standard manufacturer's warranty. For specific warranty details, technical support, or any inquiries, please contact the seller or manufacturer directly. A detailed user manual in PDF format is available for download here.
11. Frequently Asked Questions (FAQ)
No specific FAQs are available at this time. Please refer to the operation section for common setup questions.