Gaqqee XH-W3001/XH-W3002

Contents

Gaqqee W3001/W3002 Digital Temperature Microcomputer Thermostat User Manual

Models: XH-W3001, XH-W3002

1. Product Overview

The Gaqqee W3001/W3002 is a versatile microcomputer temperature controller designed for precise temperature management in various industrial and domestic applications. It features a high-brightness digital display for clear readings day or night, a wide temperature control range, and high accuracy. The device is built with an ABS material shell, ensuring durability and good electrical performance, and includes reverse connection protection for enhanced safety. The sensor is replaceable via a 2P terminal, allowing for flexibility with other probes.

Key Features:

  • Automatic mode operation
  • Wide temperature control range (-50°C to 110°C)
  • High temperature control accuracy (0.1°C)
  • Reverse connection protection
  • Easy installation
  • High-brightness digital display
  • Replaceable NTC10K waterproof probe
  • Durable ABS material shell
  • Multi-strand wire 300V/20A excess configuration for safe and reliable wiring

2. Specifications

Attribute Value
Product NameMicrocomputer temperature controller
Product ModelXH-W3001/XH-W3002
Brand NameGaqqee
Supply VoltageDC12V/24V AC220V
Temperature Measurement Range-50℃ to 110℃
Temperature Control Range-50℃ to 110℃
Temperature Control Accuracy0.1℃
Load Power120W (DC12V), 240W (DC24V), 1500W (AC220V)
Measurement InputNTC10K waterproof probe L=1 meter
Output TypeDirect output
Output CapacityMax 10A
Installation Hole Distance73mm (diameter 4mm)
Appearance Size60*45*31mm
OriginMainland China
UseIndustrial
CertificationCE
Display Size1.9 Inches & Under
Battery IncludedNo
High-concerned chemicalNone
Is Smart DeviceNo

3. Package Contents

  • Thermostat (1 unit)

4. Installation

The W3001/W3002 thermostat is constructed from a durable 1.8mm thick ABS material shell. For convenient installation and fixation, side holes are provided on both sides of the unit.

Installation Dimensions:

Installation dimension diagram for W3001/W3002 thermostat
Figure 1: Installation dimension diagram. The unit measures 60mm x 45mm x 31mm, with a hole spacing of 73mm and M4 (4mm) aperture.
W3002 renderings showing side holes for installation
Figure 2: W3002 renderings illustrating the side holes for easy mounting.

5. Wiring Diagrams

Ensure all wiring is performed by a qualified professional and that power is disconnected before making any connections to prevent electric shock or damage to the device.

5.1. 220V Wiring Method (XH-W3002)

Wiring diagram for 220V power supply to XH-W3002 thermostat
Figure 3: 220V Wiring Diagram for XH-W3002. Connect 220V power supply to the 'N' and 'L' input terminals. Connect the load (e.g., light bulb) to the 'N' and 'L' output terminals. The sensor connects to the dedicated sensor input.

5.2. 12V/24V Wiring Method (XH-W3001)

Tip: For 12V/24V W3001 power supply, you can use a transformer or a 12V/24V output DC power supply.

Note: The W3001 is a direct output device. If the output is not connected to a load, do not power on the unit to prevent potential short circuits or ignition from exposed wires.

Wiring diagram for 12V/24V power supply to XH-W3001 thermostat
Figure 4: 12V/24V Wiring Diagram for XH-W3001. Connect the 12V/24V DC power supply (e.g., battery) to the input terminals, observing polarity (+ and -). Connect the load to the output terminals, also observing polarity. The sensor connects to the dedicated sensor input.

5.3. Wiring and Setting Demonstration Video

Play video
Watch video online
Video 1: A demonstration of the wiring and setting functions for the W3001/W3002 thermostat.

6. Operation

6.1. XH-W3001 Instructions for Use

XH-W3001 panel layout with buttons and indicators
Figure 5: Introduction to the XH-W3001 Panel, showing the detection temperature display, output indicator, Up button, Down button, and Product number.

Set Startup Temperature:

  1. Press the Up button once to display the current startup temperature.
  2. Long press the Up button for approximately 3 seconds. The startup temperature number will flash.
  3. Use the Up and Down buttons to set your desired startup temperature value.

Set Stop Temperature:

  1. Press the Down button once to display the current stop temperature.
  2. Long press the Down button for approximately 3 seconds. The stop temperature number will flash.
  3. Use the Up and Down buttons to set your desired stop temperature value.

Restore Factory Settings:

When the device is powered on, press and hold both the Up and Down keys simultaneously. The digital display will show "888" and then automatically revert to the detection temperature, indicating that factory settings have been restored.

6.2. XH-W3002 Instructions for Use

XH-W3002 panel layout with buttons and indicators and setup parameter table
Figure 6: Introduction to the XH-W3002 Panel, showing the detection temperature display, output indicator, Up button, Down button, Settings button, and Product number. Also includes the Setup Parameter Table.

Setup Parameter Table:

Code Illustrate Set Range Factory Settings
P0Start temperature-50~110℃00
P1Stop temperature-50~110℃00
P2Temperature correction-10~10℃0℃
P3Delay start0~10 Minutes0 Minutes

P0: Set Startup Temperature:

  1. Press the Settings button once to enter the internal menu. The default display will be "P0".
  2. Press the Settings button again.
  3. Use the Up and Down buttons to set the required startup temperature.

P1: Set Stop Temperature:

  1. Press the Settings button once to enter the internal menu. The digital display will be "P0".
  2. Press the Up or Down buttons to switch to "P1".
  3. Press the Settings button again.
  4. Use the Up and Down buttons to set the desired stop temperature.

P2: Set Temperature Correction:

  1. Enter the internal menu (as described for P0).
  2. Use the Up or Down buttons to switch to "P2".
  3. Press the Settings button again.
  4. Use the Up and Down buttons to set the required calibration temperature.

Correction Logic: If the detected temperature is 0.5°C higher than the actual temperature, set the calibration to -0.5°C. If the detected temperature is 1°C lower than the actual temperature, set the calibration to 1°C. The formula is: Detected Temperature ± Corrected Temperature = Actual Temperature.

P3: Set Delay Start:

  1. Enter the internal menu (as described for P0).
  2. Use the Up or Down buttons to switch to "P3".
  3. Press the Settings button again.
  4. Use the Up and Down buttons to set the required delay time (unit is minutes).

Delay start is typically used for compressor refrigeration. A general setting value is 3-6 minutes, depending on the compressor back pressure. If you are not controlling a compressor or do not require a delay function, you can skip this setting.

7. Maintenance

No specific maintenance instructions are provided for this device. It is recommended to keep the unit clean and free from dust. Ensure all connections remain secure.

8. Troubleshooting

No specific troubleshooting steps are provided. If the device is not functioning as expected, please re-check all wiring connections and ensure the power supply matches the model's requirements. If issues persist, refer to the official PDF manual or contact customer support.

9. User Tips

  • For optimal performance, ensure proper wiring and calibration according to the instructions.
  • Users have noted the device's durability and precision in maintaining desired temperatures.
  • The quick delivery and value of the product have been positively highlighted by users.

10. Warranty & Support

This product comes with a standard manufacturer's warranty. For specific warranty details, technical support, or any inquiries, please contact the seller or manufacturer directly. A detailed user manual in PDF format is available for download here.

11. Frequently Asked Questions (FAQ)

No specific FAQs are available at this time. Please refer to the operation section for common setup questions.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.