1. Product Introduction
Thank you for choosing LEFOO products! Please read this manual carefully before using the product.
The LF19 series pressure switch is designed for use with air compressors or water pumps. Its primary function is to regulate the pressure within the air compressor's air pipe or the water pump system, ensuring it operates between two preset pressure values. Models equipped with an unloader valve prevent the air compressor from starting under overload conditions. A manual switch knob allows for manual control of the compressor. The four-way base interface simplifies the installation of exhaust valves and pressure gauges.
2. Safety Information and Usage Requirements
For the correct and safe use of the pressure switch, the following general information should always be followed:
- Always follow the warnings and precautions in this instruction manual.
- Comply with the regulations of professional associations and corresponding national laws and regulations.
- Adhere to specified limit values, such as pressure, force, material, or temperature, and consider environmental conditions (temperature, humidity, air pressure, etc.).
- Do not subject the pressure switch to strong impact or vibration.
- Do not make any unauthorized changes to the device.
- Remove all transportation precautions, such as protective films, covers, or cartons, before installation.
Recycling or other prescribed disposal should be carried out according to the material properties and local regulations.
3. Setup and Connection
3.1. Connection Types
The LF19 pressure switch is available in different configurations, primarily distinguished by the number of connection holes:
- LF19-1H: Single-hole pressure controller.
- LF19-4H: Four-hole pressure controller.
3.2. Thread and Unloader Valve Variations
The LF19 series has both old and new style designs, primarily differing in thread dimensions and unloader valve connections:
- Old Style: May feature M12*1.5 Thread and 1/4 Thread connections.
- New Style: May feature M11*1 Thread and 1/4 Thread connections.
3.3. Electrical Connection
WARNING: The power supply of the system must be cut off during all installation processes.
When installing the switch on an air pump with 380V, it is mandatory to use a relay in conjunction with the switch to control the signal line of the circuit. For 110V-220V air pumps with small power, the switch can be connected directly.
4. Operating Instructions
4.1. Manual On/Off Control
The red knob on the top of the pressure switch allows for manual ON/OFF control of the connected device (air compressor or water pump).
4.2. Pressure Adjustment
The LF19 pressure switch allows for adjustment of both the operating pressure range and the pressure differential.
- Adjusting Operating Pressure (Cut-in/Cut-off values):
- When the main adjustment pressure bolt (P) is turned **downward**, both the upper and lower pressure values of the switch increase simultaneously.
- When turned **upward**, both the upper and lower pressure values decrease.
- This adjustment sets the overall pressure range at which the switch operates.
- Adjusting Pressure Differential (ΔP):
- When the pressure differential adjustment bolt (ΔP) is turned **downward**, the upper pressure value remains unchanged, but the lower pressure value decreases.
- When turned **upward**, the upper pressure value remains unchanged, and the lower pressure value increases.
- This adjustment primarily affects the pressure starting value of the switch.
5. Maintenance
The LEFOO LF19 pressure switch is designed for durability and requires minimal maintenance. To ensure optimal performance and longevity:
- Keep the device clean and free from dust, debris, and moisture.
- Regularly inspect the connections for any signs of wear, corrosion, or looseness.
- Ensure the operating environment adheres to the specified temperature and humidity ranges.
- Avoid exposing the switch to harsh chemicals or solvents.
No user-serviceable parts are inside beyond the pressure adjustment mechanisms. For any complex issues, consult a qualified technician.
6. Troubleshooting
This section provides general guidance for common issues. For detailed diagnostics, it is recommended to consult a qualified professional.
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor does not start | No power, switch in OFF position, or pressure too high (if unloader valve is present and stuck). | Check power supply. Ensure switch is in ON position. Verify unloader valve is functioning correctly. |
| Compressor runs continuously | Pressure setting too high, or switch malfunction. | Adjust pressure settings. If issue persists, consult a technician. |
| Inconsistent pressure control | Incorrect pressure differential setting, or internal wear. | Re-adjust pressure differential. If problem continues, seek professional help. |
7. Specifications
| Technical Parameter | Specification |
|---|---|
| Model | LF19-1H, LF19-4H |
| Rated Voltage | 250VAC (also compatible with 220/380VAC systems with appropriate relay) |
| Rated Current | 16A/25A |
| Switch Type | Pressure Switch, Normally Closed (NC) |
| Mechanical Life | 105 cycles |
| Electrical Life | 3×104 cycles |
| Electrical Contact Material | Silver Alloy |
| External Contamination | Normal |
| Applicable Standard | EN 60730-1 |
| Interface Form (Internal) | NPT: 1/4, 3/8, 1/2; G: 1/4, 3/8, 1/2; R: 1/4, 3/8, 1/2 |
| Maximum Working Pressure | 14bar |
| Set Pressure Range | 1-6 bar / 2-11 bar / 5-14 bar |
| Set Pressure Differential | 1-3 bar / 1.4-3.5 bar / 1.8-4.0 bar |
| Material | Plastic |
| Certification | CE, CCC |
| Is Smart Device | No |
| Origin | Mainland China |
| Color | Black |
Unit Conversion: 1 kgf/cm² = 14.2 psi = 0.1 MPa
For a detailed order reference and specification table, please refer to the official PDF manual: LF19 User Manual (PDF).
8. User Tips
- Choosing the Right Switch: If you are replacing an existing switch, use your old switch as a reference. Otherwise, carefully select the parameters (e.g., 1-hole or 4-hole, pressure range, thread type) based on your specific application requirements.
- Wiring for 380V Systems: Always use a relay when connecting the LF19 switch to a 380V air pump to ensure proper control and safety. For 110V-220V systems with lower power, direct connection is typically acceptable.
- Pressure Unit Conversion: Remember that 1 KG/cm² is approximately equal to 14.2 psi or 0.1 MPa when setting your desired pressure values.
9. Warranty and Support
LEFOO sincerely thanks you for using our products. This series of products can be customized according to specific performance requirements. For details, please contact the local business or technical personnel for docking.
Company Information:
Zhejiang Lefoo Automatic Control Technology Co., Ltd.
No.220, 15th Weilu Road, Yueqing Economic Development Zone, Wenzhou City, Zhejiang Province, China
Tel: 0577-27822222
Website: www.lefoo.cn
For warranty claims or technical support, please contact the manufacturer directly using the provided contact information.