1. Introduction

The Hi-Link 5W DC-DC Isolated Converter module is a compact power solution featuring a 2:1 wide voltage input range and an efficiency of up to 84%. It provides 1500VDC conventional isolation voltage and operates reliably across a wide temperature range of -40°C to +85°C. The module incorporates essential protection features including output over-voltage, over-current, and short circuit protection. Its robust design, including a metal shell and international standard pins for PCB in-line installation, ensures low output ripple and high reliability. These converters are widely applicable in medical, industrial control, electric power, instrumentation, communication, and railway systems.

Video: Overview of various Hi-Link AC/DC and DC/DC power modules, showcasing their range and applications.

2. Safety Information

Please read and understand the following safety precautions before installing or operating the DC-DC converter module:

  • Ensure proper ventilation around the module to prevent overheating.
  • Do not exceed the specified input voltage range. Exceeding the maximum input voltage may cause permanent damage to the product.
  • Observe correct polarity for input and output connections. Incorrect wiring can damage the module and connected devices.
  • The module provides output short circuit, over current, and over voltage protection. However, continuous operation under fault conditions should be avoided.
  • Installation should be performed by qualified personnel familiar with electronic components and safety standards.
  • The module is designed for PCB in-line installation. Ensure secure soldering to prevent loose connections.
  • The metal shell provides protection; however, avoid physical impact or excessive force on the module.

3. Product Features

  • Ultra-wide input voltage range (2:1)
  • Output power: 5W
  • High conversion efficiency: up to 84% (Typical)
  • Isolation voltage: 1500VDC
  • Ultra-low standby power consumption: 0.3W (Typical)
  • Ultra-fast start-up time: 100mS (Typical)
  • Wide operating temperature range: -40°C to +85°C
  • Comprehensive output protection: Short circuit protection, over current protection, over voltage protection
  • Durable metal case with low output ripple
  • International standard pins for PCB in-line installation
  • Sealed with high-quality environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements.
  • High reliability and long-life design for continuous operation.

4. Specifications

4.1. Product Coding Rules

The model number provides information about the product's characteristics:

HLK-XXX XX XX XXX-XX XX

  • HLK: Product brand
  • XXX (first set): Product type
  • XX (first set): Input voltage
  • XX (second set): Output voltage
  • XXX (second set): Package code
  • XX (third set): Output power
  • XX (fourth set): Scheme type

4.2. Product Selection Table (5W Series)

Below is a selection of typical products. For specific models not listed, please contact the manufacturer.

ModelInput Voltage Range (Vdc)Output Voltage (Vdc)Output Current (mA)Ripple & Noise (mVp-p)Max. Capacitive Load (µF)Efficiency (%)
VRB0505YMD-5WR35 (4.5~9)5100030/50100076/78
VRB0512YMD-5WR35 (4.5~9)1241650/8047078/80
VRB1203YMD-5WR312 (9~18)3.3120030/50250075/77
VRB1205YMD-5WR312 (9~18)5100030/50220076/78
VRB1212YMD-5WR312 (9~18)1241650/8068078/80
VRB1215YMD-5WR312 (9~18)1533350/8047079/81
VRB1224YMD-5WR312 (9~18)2420850/8022081/83
VRA1205YMD-5WR312 (9~18)±5±50030/50110076/78
VRB2403YMD-5WR324 (18~36)3.3120030/50250075/77
VRB2405YMD-5WR324 (18~36)5100030/50220076/78
VRB2412YMD-5WR324 (18~36)1241650/8068080/82
VRB2424YMD-5WR324 (18~36)2420850/8022082/84
VRB4805YMD-5WR348 (36~72)5100030/50220076/78
VRB4812YMD-5WR348 (36~72)1241650/8068080/82
VRB4824YMD-5WR348 (36~72)2420850/8022082/84

Note: The maximum capacitive load indicates the maximum capacitive load that can be connected to +Vo or -Vo. If it exceeds this value, the product will not be able to start normally. If the input voltage exceeds the maximum value, it may cause permanent damage to the product.

4.3. Input Features

ProjectWorking ConditionsMin.Typ.Max.Unit
Input Current (full load/no load)12VDC Nominal Input Series, Nominal Input Voltage (3.3V Output)-428/25440/30mA
24VDC Nominal Input Series, Nominal Input Voltage (3.3V Output)-214/13220/15mA
48VDC Nominal Input Series, Nominal Input Voltage (3.3V Output)-107/7110/8mA
Impulse Voltage (Isec.max)12VDC Nominal Input Series-0.7-30VDC
Starting Voltage12VDC Nominal Input Series--9VDC
Startup TimeNominal input voltage and constant resistance load-100-mS
Input Filter Type--PI type--
Hot Plug--Not support--

4.4. Output Features

ProjectWorking & Test ConditionsMin.Typ.Max.Unit
Output Voltage AccuracyInput voltage range-±1.0%±2.0%-
Linear Adjustment RateInput voltage range-±0.2%±0.5%-
Load Regulation20%~100% rated load, balanced load-±0.5%±1%-
Ripple & NoisePure resistive load, 20MHz bandwidth, peak-to-peak-50mVp-p80mVp-p-
Startup Delay Time--100ms--

4.5. General Features

ProjectWorking ConditionsMin.Typ.Max.Unit
Insulation VoltageInput-output, test time: 1 minute, leakage current < 1mA1500--VDC
Insulation ResistanceInput-output, insulation voltage1000--MΩ
Isolation CapacitorInput-Output, 100KHz/0.1V-1000-pF
Working TemperatureReference temperature derating curve-40-+85°C
Storage Temperature--40-+125°C
Working Max Case Temperature---+100°C
Storage HumidityNo condensation5-95%RH
Pin Soldering TemperatureThe solder joint is 1.5mm away from the shell, 10 seconds--+300°C
On-off LevelPWM mode-250-KHz
Vibration--10-55Hz, 10G, 30Min. along X, Y and Z--
Shell Material--Aluminum shell--

4.6. Temperature Characteristic Curve

Temperature derating curve for the DC-DC converter, showing output power percentage versus ambient temperature.
Figure 1: Temperature Derating Curve

5. Pin Description

The module features standard pins for easy integration into PCB designs. The pinout varies slightly between single and dual output versions.

Pin diagram and package dimensions for the Hi-Link DC-DC converter module.
Figure 2: Package Size and Pin Function Diagram
Pin No.Single Output (S)Dual Output (D)
1-Vin (Input negative)-Vin (Input negative)
2+Vin (Input positive)+Vin (Input positive)
3+Vo (Output positive)+Vo1 (Output positive 1)
4NP (No contact)COM (Common)
5GND (Output ground)-Vo2 (Output negative 2)
6NC (No contact)NC (No contact)

Note: If the definition of each pin on the physical label is inconsistent with this manual, the physical label shall prevail.

6. Setup and Installation

For optimal performance and stability, it is generally recommended to use external capacitors:

  • C1: 47-100µF
  • C2, C3: 10-22µF
Recommended DC/DC test circuit diagram with input and output capacitors.
Figure 3: Recommended DC/DC Test Circuit

For applications requiring general ripple & noise performance, using only C2 and C5 for the periphery is sufficient. For strict ripple & noise requirements, the full circuit shown below is recommended.

EMC peripheral recommended circuit for single and dual output products, including filters and capacitors.
Figure 4: EMC Peripheral Recommended Circuit

Note:

  • C2, C3, C5, C6 use high-frequency low-resistance electrolytic capacitors. The total capacity should not exceed the maximum capacitive load specified in the manual, otherwise the module may not start normally.
  • When using capacitive loads, a minimum load of 3% must be guaranteed to prevent abnormal module output.
  • LDM5 is only used for dual output products.

6.3. Parameter Recommendation for EMC Circuit

Device Code12V Input Product24V Input Product48V Input Product110V Input Product
FMSE FuseAccess the corresponding fuse according to customer needs
MOV Varistor14D330K14D560K14D101K14D201K
LDM1 Common Mode Inductance10mH10mH15mH30mH
E1, E2 Electrolytic Capacitor100µF/50V100µF/50V100µF/100V63µF/200V
C0, C1 Ceramic Capacitors1µF/50V1µF/50V1µF/100V0.47µF/250V
LDM2 Differential Mode Inductance10µH10µH15µH68µH
CY1 Safety Y2 Capacitor1nF/250Vac

Parameter recommendations for LDM3, LDM4, LDM5 inductances and C2, C3, C4, C5, C6, C7 capacitors vary based on output voltage and type (single/dual output). Please refer to the full datasheet for specific values for your model.

7. Operating Instructions

The Hi-Link DC-DC converter modules are designed for straightforward operation once correctly installed. Follow these guidelines for optimal performance:

  • Input Voltage: Apply DC voltage within the specified input range for your specific module (e.g., 9-18V for 12V input models, 18-36V for 24V input models, 36-72V for 48V input models, 72-144V for 110V input models).
  • Output Loading: Ensure the load connected to the output does not exceed the maximum output current specified for your model. For capacitive loads, maintain a minimum load of 3% to ensure stable output.
  • Temperature: Operate the module within the ambient temperature range of -40°C to +85°C. Refer to the temperature derating curve (Figure 1) to understand how output power may be affected at higher temperatures.
  • Protection Features: The module is equipped with output short circuit, over current, and over voltage protection. In case of a fault, the module will protect itself. Address the fault condition before resuming operation.
  • Ripple & Noise: For sensitive applications, consider implementing the recommended EMC peripheral circuit (Figure 4) to minimize output ripple and noise.
A Hi-Link DC-DC converter module being tested with a multimeter, showing a stable 5.021V output.
Figure 5: Module undergoing testing, demonstrating stable output voltage.

8. Maintenance

The Hi-Link DC-DC Isolated Converter modules are designed for high reliability and long life, requiring minimal maintenance. However, adhering to the following guidelines can help ensure continued optimal performance:

  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposure to excessive moisture, dust, or corrosive substances. The IP65 rating provides good protection against dust and water jets, but submersion should be avoided.
  • Physical Inspection: Periodically inspect the module and its connections for any signs of physical damage, loose solder joints, or discoloration.
  • Cleaning: If necessary, gently clean the module's exterior with a soft, dry cloth. Do not use harsh chemicals or abrasive materials.
  • Ventilation: Ensure that any surrounding components or enclosures do not obstruct airflow around the module, especially if operating at higher temperatures or near maximum load.

9. Troubleshooting

If you encounter issues with your Hi-Link DC-DC converter module, consider the following common troubleshooting steps:

  • No Output Voltage:
    • Check input voltage: Verify that the input voltage is within the specified range and correctly connected to the +Vin and -Vin pins.
    • Check polarity: Ensure input and output polarities are correct.
    • Check load: Disconnect the load to see if the module starts. An excessive capacitive load can prevent the module from starting normally. Ensure minimum load requirements are met for capacitive loads.
    • Check for short circuits: Inspect the output for any short circuits. The module has short circuit protection, which may prevent it from operating until the fault is cleared.
  • Unstable Output / High Ripple:
    • Check external capacitors: Ensure recommended input and output capacitors (C1, C2, C3) are correctly installed and of the appropriate values.
    • Verify load conditions: Ensure the load is stable and within the module's capabilities.
    • Review EMC circuit: If ripple is critical, ensure the recommended EMC peripheral circuit is correctly implemented.
  • Overheating:
    • Check ambient temperature: Ensure the operating temperature is within the specified range.
    • Ensure proper ventilation: Clear any obstructions around the module that might impede heat dissipation.
    • Reduce load: If operating near maximum load in high ambient temperatures, consider reducing the load or improving cooling.

10. User Tips

  • Stable Output: Users have reported excellent voltage regulation, with a 12V output module maintaining 12.06V even with input variations between 12V and 14.6V. This indicates reliable performance within specified ranges.
  • Datasheet Accuracy: Bench tests confirm that the product parameters align with the provided datasheet, ensuring predictable performance for your designs.
  • Durable Construction: The module features a metal casing, which provides enhanced durability and heat dissipation compared to plastic enclosures.

11. Warranty and Support

For technical support, inquiries, or warranty claims, please contact Shenzhen Hi-Link Electronic Co., Ltd using the information below:

  • Address: 3rd Floor, Building 1, 1970 Science and Technology Park, Minzhi, Longhua District, Shenzhen, Guangdong, China 518131
  • Website: www.hlktech.net
  • E-mail: sales@hlktech.com
  • Tel: 0755-23152658

Hi-Link has over 15 years of experience in R&D, production, and sales service, serving more than 100,000 customers in 80 countries. They hold CE/FCC/ROSH certifications for their products.

© 2024 Hi-Link. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.