1. Introduction
The XH-W3002 is a versatile microcomputer temperature controller designed for precise temperature management across various applications. It features a high-brightness digital display for clear readability in any lighting condition, and a replaceable NTC10K waterproof probe for accurate temperature measurement. Its robust design, including an ABS material shell, ensures good electrical performance and anti-aging properties, making it suitable for a wide range of industrial control equipment.
2. Specifications
| Attribute | Value |
|---|---|
| Product Name | Microcomputer temperature controller |
| Product Model | XH-W3002 |
| Temperature Measurement Range | -50 to 110℃ |
| Temperature Control Range | -50 to 110℃ |
| Temperature Measurement Accuracy | ±0.2℃ |
| Temperature Control Accuracy | ±0.1℃ |
| Measurement Input | NTC10K L=1 meter waterproof probe |
| Input Power | DC12V / DC24V / AC110V-220V |
| Output Power | 120W (for 12V), 240W (for 24V), 1500W (for 110-220V AC) |
| Output Type | Direct output |
| Output Capacity | Max 10A |
| Installation Hole Distance | 73mm (diameter 4mm) |
| Appearance Size | 60*45*31mm |
| Material | 1.8mm thick ABS material shell |
| Certification | CE |
3. Safety Information
Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Always disconnect power before performing any wiring or maintenance.
- Ensure the input voltage matches the specific model of your XH-W3002 controller (DC12V, DC24V, or AC110V-220V). Incorrect voltage can damage the device.
- When connecting the output, ensure it is properly connected to a load. For DC versions, avoid powering on if the output is not connected to a load to prevent potential issues from two-level wire contact and ignition.
- Do not exceed the maximum output capacity of 10A.
- Keep the device away from water, high humidity, and flammable materials.
- Installation should be performed by qualified personnel if you are unsure about electrical wiring.
4. Package Contents
- 1 x XH-W3002 Temperature Controller
5. Installation
5.1 Physical Installation
The XH-W3002 features a durable 1.8mm thick ABS material shell. For convenient mounting, there are side holes on both sides of the unit, allowing for easy installation and fixation using screws.

5.2 Wiring Diagrams
Ensure all power is disconnected before proceeding with wiring. Connect the sensor probe to the designated sensor input on the controller.
5.2.1 220V AC Wiring Method

Connect the 220V AC power supply to the 'N' and 'L' input terminals. Connect your 220V AC load (e.g., heating element, fan) to the 'N' and 'L' output terminals. The sensor should be connected to its dedicated input.
5.2.2 12V/24V DC Wiring Method

For 12V or 24V DC operation, connect your DC power supply (e.g., battery, DC transformer) to the positive (+) and negative (-) input terminals. Connect your 12V or 24V DC load to the positive (+) and negative (-) output terminals. The sensor should be connected to its dedicated input. Note: When the output is not connected to a load, please do not power on the device to prevent potential issues from two-level wire contact and ignition.
6. Operating Instructions
6.1 Panel Introduction

The control panel consists of a digital display, an 'Output indicator' LED, a 'Settings' button, an 'Up' button, and a 'Down' button.
6.2 Setting Parameters
The XH-W3002 allows you to configure several parameters for precise temperature control:
| Code | Function | Set Range | Factory Settings |
|---|---|---|---|
| P0 | Start Temperature | -50 to 110℃ | 00 |
| P1 | Stop Temperature | -50 to 110℃ | 00 |
| P2 | Temperature Correction | -10 to 10℃ | 0℃ |
| P3 | Delay Start | 0 to 10 Minutes | 0 Minutes |
To set a parameter:
- Press the 'Settings' button once to enter the internal menu. The default display is 'P0'.
- Use the 'Up' and 'Down' buttons to navigate to the desired parameter (P0, P1, P2, or P3).
- Press the 'Settings' button again to enter the setting mode for that parameter.
- Use the 'Up' and 'Down' buttons to adjust the value.
- Press the 'Settings' button again to save the setting and exit, or wait a few seconds for it to automatically save and exit.
Specific Parameter Notes:
- P2 (Temperature Correction): This function allows you to calibrate the temperature reading. For example, if the detected temperature is 0.5℃ higher than the actual temperature, set P2 to -0.5℃. If it's 1℃ lower, set P2 to 1℃.
- P3 (Delay Start): This is typically used for compressor refrigeration to prevent frequent cycling. The general setting value is 3-6 minutes, depending on the compressor's back pressure. If you do not need this function, you can skip it.
6.3 Video Demonstration
7. User Tips
- Voltage Stability: For DC versions (12V/24V), especially in environments with potential voltage fluctuations like solar systems, ensure a stable power supply. Some users have reported sensitivity to voltage spikes, which can lead to component failure. Consider using a voltage regulator or a controller with a wider operating voltage range if your application is prone to such issues.
- Load Management: Always ensure your connected load's current draw does not exceed the controller's maximum output capacity (10A). Overloading can cause the device to overheat and fail.
- Initial Setup: Before connecting the final load, it's good practice to test the controller's settings and temperature response with a simple test load or by observing the output indicator.
8. Troubleshooting
- Device not powering on:
- Check if the power supply is correctly connected and providing the specified voltage (12V, 24V, or 110-220V AC).
- Ensure the power source is active. - Temperature reading inaccurate:
- Verify the sensor probe is properly connected to the controller and is correctly placed in the environment where temperature is to be measured.
- Use the P2 (Temperature Correction) parameter to calibrate the reading if there's a known offset. - Output not switching (load not turning on/off):
- Check the P0 (Start Temperature) and P1 (Stop Temperature) settings to ensure they are configured correctly for your desired operation.
- Confirm that the output load is properly wired and functional.
- Ensure the load's current draw does not exceed the maximum 10A output capacity. - Device stops working or shows signs of damage (e.g., burning smell, no display):
- Immediately disconnect power.
- This could indicate an internal component failure, possibly due to incorrect wiring, overvoltage, or exceeding the load capacity. Inspect for any visible damage to components like resistors. If damage is evident, the unit may need replacement.
9. Maintenance
- Keep the controller clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to direct sunlight, extreme temperatures, or high humidity.
- Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
- Do not attempt to open the casing or repair the device yourself, as this may void the warranty and pose safety risks.