1. Product Overview
The Gaqqee DC Current Detection Relay Module is designed to monitor DC current within a specified range. It can detect if the current is too large or too small, subsequently controlling a relay switch to turn a circuit on or off, or to provide a signal. This module features a digital display for current readings, error calibration, and a compact design for various applications.

Figure 1: Gaqqee DC Current Detection Relay Module
Video 1: Product overview and demonstration of the DC current detection relay module.
2. Specifications
| Feature | Description |
|---|---|
| Model Number | Overcurrent Protection Relay Module |
| Detection Range | DC current between 0~10A |
| Detection Accuracy | 0.01A (10mA) |
| Voltage | 12V |
| Power Source | DC |
| Standby Current | Approximately 20mA |
| Relay Output | Controls on-off of DC line within 5A |
| Theory | Voltage relay |
| Contact Load | High Power |
| Protection Feature | Sealed |
| Certification | CE |
| EU LVD Voltage | Below 50Vac or 75Vdc |
3. Setup Instructions
Before proceeding, ensure the module is connected to a stable 12V DC power supply and the current sensing terminals are correctly wired in series with the circuit you wish to monitor.

Figure 2: Top-down view of the relay module showing the digital display, control buttons (K1, K2, K3), and terminal blocks.
- Power On: Apply 12V DC power to the module. The digital display will show the measured current. (If the current terminal is floating, a reading on the digital display is normal).
- Enter Setup Mode (First Press K1): Press and hold button K1 for more than 1 second to prevent false triggering. The screen will display
P 11, indicating K2 is for adjustment mode and K3 is for adjustment function. - Set Threshold I1 (Second Press K1): Press K1 again. The screen will flash and display a value (e.g.,
0.05, representing 0.05A for threshold I1).- Use button K2 to increase the value of I1.
- Use button K3 to decrease the value of I1.
- Set Threshold I2 (Third Press K1): Press K1 a third time. The screen will flash and display a value (e.g.,
0.10, representing 0.1A for threshold I2).- Use button K2 to increase the value of I2.
- Use button K3 to decrease the value of I2.
- Enter Standby State (Fourth Press K1): Press K1 a fourth time. The screen will display the measured current, indicating the module has entered the standby state and is ready for operation.
- Fine-tune Current Error: In the standby state, long-press K2 or K3 to fine-tune the measured current error if necessary.
4. Operating Modes (Function Description)
The module supports various operating modes, configured during setup, which dictate how the relay responds to current thresholds I1 and I2.

Figure 3: Angled view of the relay module highlighting the SRD-05VDC-SL-C relay and input/output terminals.
- P-11: Overcurrent Pull-in, Undercurrent Disconnect
When the measured current is greater than I1, the relay pulls in. When the measured current drops below I1 again, the relay disconnects. - P-12: Overcurrent Pull-in, Latching
When the measured current is greater than I1, the relay pulls in and remains pulled in until the power supply to the circuit board is cut off. - P-21: Overcurrent I2 Pull-in, Undercurrent I1 Disconnect
When the measured current is greater than I2, the relay pulls in. When the measured current drops below I1, the relay disconnects. - P-22: Overcurrent I2 Pull-in, Latching
When the measured current is greater than I2, the relay pulls in and remains pulled in until the power supply to the circuit board is cut off. - P-31: Undercurrent I1 Close, Overcurrent I2 Disconnect
When the measured current is less than I1, the relay closes. When the current becomes greater than I2, the relay disconnects. - P-32: Undercurrent I1 Pull-in, Latching
When the measured current is less than I1, the relay pulls in and remains pulled in until the power supply to the circuit board is cut off. - P-41: Current Between I1 and I2 Pull-in, Otherwise Disconnect
When the measured current is between I1 and I2, the relay pulls in. In all other cases (current < I1 or > I2), the relay is disconnected. - P-42: Current Between I1 and I2 Pull-in, Latching
When the measured current is between I1 and I2, the relay pulls in and remains pulled in until the power supply to the circuit board is cut off. - P-51: Current Outside I1-I2 Range Pull-in, Otherwise Disconnect
When the measured current is less than I1 or greater than I2, the relay pulls in. In all other cases (current between I1 and I2), the relay is disconnected. - P-52: Current Outside I1-I2 Range Pull-in, Latching
When the measured current is less than I1 or greater than I2, the relay pulls in and remains closed until the power supply to the circuit board is cut off.
5. Maintenance
The Gaqqee DC Current Detection Relay Module is designed for durability and long service life. Minimal maintenance is required.
- Cleaning: Keep the module free from dust and debris. Use a soft, dry cloth to gently wipe the surface. Avoid using liquids or abrasive cleaners.
- Environmental Conditions: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, moisture, or corrosive environments.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
6. Troubleshooting
- No Display/No Power:
- Check the 12V DC power supply connection. Ensure it is correctly wired and providing the correct voltage.
- Verify the power source is active.
- Incorrect Current Reading:
- Ensure the current sensing terminals are correctly wired in series with the load.
- Perform the fine-tuning procedure (long-press K2 or K3 in standby) to calibrate the current reading.
- Check for any loose connections in the current path.
- Relay Not Activating/Deactivating as Expected:
- Review the selected operating mode (P-xx) and ensure the I1 and I2 thresholds are set correctly for your application.
- Verify that the measured current is indeed crossing the set thresholds.
- Ensure the load connected to the relay does not exceed its 5A DC rating.
- Module Unresponsive:
- Disconnect power, wait a few seconds, and then reconnect power to perform a soft reset.
7. User Tips
Based on general usage of similar modules, here are some tips:
- Test Thoroughly: Before deploying in a critical application, thoroughly test the module's behavior with your specific load and current conditions to ensure it operates as expected.
- Clear Labeling: Label your I1 and I2 settings if you frequently change them or have multiple modules.
- Power Supply Quality: Use a stable and clean 12V DC power supply to ensure accurate readings and reliable operation.
For more detailed information, you may refer to the official user manual PDF: View User Manual (PDF)