TOWE TW-F-C13L/C14

Contents

TOWE Locking IEC 320 C14 to C13 Power Cord

Professional User Manual

1. Product Overview

The TOWE professional power cord series is designed for server racks, UPS systems, PDUs, industrial equipment, and data center applications. This locking power cord ensures a secure and stable power connection, preventing accidental disconnections in critical environments.

TOWE Locking IEC 320 C14 to C13 Power Cord
TOWE Locking IEC 320 C14 to C13 Power Cord
TOWE C13-C14 Locking Power Cord with logo
TOWE C13-C14 Locking Power Cord

2. Main Features

  • IEC 320 international standard connectors (C14 Male End, C13 Female End)
  • Secure locking retention system to prevent accidental disconnection
  • Oxygen-free copper conductor for efficient power transmission
  • UL94 flame retardant housing for enhanced safety
  • Integrated molded construction for durability
  • Available in various cable lengths and connector combinations
C13-C14 Self Locking Power Conversion Cable for Data Center Server Security Cord
C13-C14 Self Locking Power Conversion Cable for Data Center Server Security Cord
Diagram showing how a self-locking power cord solves power failure issues in server devices.
Small Component Solve Big Problem: Addressing power failure in server devices with self-locking cords.
Close-up of the C13-C14 Self Locking Power Conversion Cable, emphasizing safety.
Use Self-locking, Be Safer: Ensuring safety and stability of server equipment.

3. Technical Specifications

Item Specification
Rated Voltage 250V AC
Rated Current 10A / 15A / 16A
Cable Type SJT / PVC
Wire Gauge 3x1.0mm² / 3x1.5mm² / 14AWG
Conductor Oxygen-Free Copper
Connector Types C13 / C14 / C19 / C20
Cable Length 0.5M - 30M (1m, 1.8m, 3m options available)
Flame Rating UL94
Certification UL, 3C Certification
EU LVD Voltage High voltage: Above 50Vac or 75Vdc
Wireless Functionality No
Battery Included No
Product Parameter table showing wire gauge, current, voltage, and power for 1.0mm² and 1.5mm² cables.
Detailed Product Parameters for 1.0mm² and 1.5mm² cables.
Diagram showing six specifications optional for wire diameter and length.
Six Specifications Optional: Multi-specification options to satisfy different demands.
Cross-section diagram of the cable showing eco-friendly flame retardant PVC material and oxygen-free copper conductors.
Cable Construction: Eco-friendly flame retardant PVC and Oxygen-free Copper.
Images showing 3C Certification marks on the cable and connectors.
3C Certification: Ensuring safety and reliability.

4. Applications

This power cord is primarily used in environments requiring stable and secure power connections. Common applications include:

  • Server Racks
  • Data Centers
  • UPS Systems (Uninterruptible Power Supplies)
  • Industrial PDUs (Power Distribution Units)
  • Communication Cabinets
  • Office Equipment
Diagram showing C14 Plug and C13 Self Locking Socket, and devices like Computer Host, PDU Socket, UPS Power Supply, Server.
Applicable Devices: Computer Host, PDU Socket, UPS Power Supply, Server.
Images of various plug types: C14 Plug, C20 Plug, G10 Plug, G16 Plug.
Various Plug Types: C14, C20, G10, G16.

5. Installation Instructions (Setup)

  1. Confirm Compatibility: Ensure the C14 male end of the power cord is compatible with your power source (e.g., PDU, UPS) and the C13 female end is compatible with your device (e.g., server, computer host).
  2. Prepare for Connection: Hold the C13 self-locking socket. Press and hold the red part on the C13 connector to prepare for insertion.
  3. Connect to Device: Plug the C13 self-locking socket firmly into the power jack of your server device or other compatible equipment.
  4. Engage Locking Mechanism: Once fully inserted, release the red part. This will engage the self-locking mechanism, securing the connection and preventing accidental dislodgement.
  5. Verify Connection: Gently tug on the cable to ensure the locking latch is engaged and the connection is stable.
Hand pressing the red locking button on the C13 connector.
Step 1: Press and hold the red part to push down.
Hand plugging the C13 connector into a server device's power jack.
Step 2: Plug into the power jack of the server device.
Hand releasing the red locking button after the C13 connector is inserted, achieving self-locking.
Step 3: After inserting in place, release it to achieve self-locking. Note: Without pushing down the red part, the C13 connector end cannot be pushed out to achieve "self-locking" without leakage.
Video demonstrating the connection process of the locking power cord.

6. Safety Instructions

  • Do not exceed the rated current (10A/15A/16A) or voltage (250V AC) of the power cord.
  • Keep the power cord dry and away from moisture.
  • Ensure proper grounding of all connected equipment.
  • Replace damaged cables immediately to prevent electrical hazards.
  • Do not attempt to modify or repair the power cord. Contact technical support if damaged.
  • Avoid bending the cable sharply or placing heavy objects on it to prevent internal damage.

7. Maintenance

  • Regularly inspect the cable jacket for any signs of cuts, abrasions, or damage.
  • Check connectors for wear, corrosion, or deformation.
  • Verify the locking retention mechanism is functioning correctly.
  • Look for any signs of overheating, such as discoloration or melting on the cable or connectors.
  • Keep the cable clean and free from dust and debris.

8. Troubleshooting

  • No Power Output:
    • Verify the power source is active and supplying power.
    • Check that both ends of the power cord are securely seated and the locking latch is engaged.
    • Inspect the power cord for visible damage. If damaged, replace it.
    • Ensure the connected device is functioning correctly and its power switch is on.
  • Overheating:
    • If the cable or connectors feel hot, it may indicate an overload or poor contact.
    • Immediately disconnect the power cord.
    • Ensure the connected equipment's power requirements do not exceed the cable's rated current.
    • Check for loose connections or damaged pins.
  • Cable Disconnects Accidentally:
    • Ensure the locking mechanism on the C13 connector is fully engaged after insertion.
    • Inspect the C13 connector for any damage to the locking latch.
Animated comparison showing a regular power cord easily detaching versus a Towe self-locking type remaining secure.
Style Comparison: Towe Self-locking Type vs. Regular Type on the Market, highlighting the secure connection.

9. User Tips

  • Always ensure the red locking tab on the C13 connector clicks into place to guarantee a secure connection, especially in vibration-prone environments like server racks.
  • When disconnecting, remember to press the red tab firmly before pulling the connector to avoid damaging the locking mechanism or the equipment's power inlet.
  • Consider cable management solutions to reduce strain on the connectors and prevent accidental disconnections.

10. Technical Support

For further assistance, technical inquiries, or support, please contact TOWE Professional Electrical Connection Solutions.

Website: www.towe.com.cn

A user manual in PDF format is also available for download: User manual (PDF)

© 2024 TOWE. All rights reserved.