1. Introduction
This manual provides essential information for the safe and efficient operation of your HLTNC YL586K Vector VFD Inverter. Please read this chapter carefully when installing, debugging, and servicing this system, and be sure to follow the safety precautions required. Any injuries and losses caused by illegal operations are not the responsibility of the company.

Figure 1.1: HLTNC YL586K Vector VFD Inverter
2. Safety Information and Precautions
Safety definitions in this manual are categorized as follows:
- Danger: Indicates a situation where failure to operate as required may cause serious injury or even death.
- Note: Indicates a situation where failure to operate as required may result in moderate injury or minor injury, and equipment damage.
Always ensure proper installation, debugging, and servicing according to these guidelines to prevent accidents and damage.
3. Specifications
The HLTNC YL586K series inverters are available in various configurations. Below is a summary of key specifications:
| Attribute | Value |
|---|---|
| Model Number | YL586K |
| Type | DC/AC Inverters |
| Input Voltage | 110V / 220V / 380V |
| Output Power | 0.75KW / 1.5KW / 2.2KW |
| Output Frequency | 0-3200Hz |
| Output Phase Number | 3 |
| Size (L*W*H) | 110*85*145mm |
| Weight | 1kg |
| Certification | CE |
For detailed model-specific technical data, refer to the comprehensive table in the official PDF manual.

Figure 3.1: Product Appearance and Installation Dimensions
4. Electrical Installation
4.1 Main Circuit Terminals and Wiring
The main circuit terminals are used for power input, braking resistor connection, and motor output. Ensure all connections are secure and correct according to the wiring diagram.
- R, S, T: Power input terminals (Single-phase 220V AC power connection point).
- P+, PB: Braking resistor connection.
- U, V, W: Inverter output to connect a three-phase motor.
- Ground Terminal: For grounding.
4.2 Wiring Mode of Inverter Control Circuit
The control circuit wiring is crucial for proper functionality. The diagram below illustrates the connections for a three-phase 380V inverter. The weak analog voltage signal is particularly susceptible to external interference, so use shielded cables and keep wiring distances short (not more than 20m). If severe disturbance occurs, add a filter capacitor or ferrite magnet to the analog signal source side.

Figure 4.1: Wiring Diagram of Inverter Control Circuit
4.3 Control Terminals Function Description
The control terminals provide various input and output functions:
| Terminal Symbol | Function | Description |
|---|---|---|
| +10V-GND | External +10V Power Supply | Provides 10V power, max 150mA (short-circuit protected). Used for external potentiometer (1kΩ ~ 5kΩ). |
| +24V-GND | External +24V Power Supply | Provides 24V power for digital I/O and external sensors, max 200mA. |
| AI1-GND | Analog Input Terminal 1 | Input range: DC 0-10V / 0-20mA. Input impedance: 22kΩ (voltage) / 500Ω (current). |
| DI1-GND to DI5-GND | Digital Input Terminals | Used for various digital signals. DI5 can also be a high-speed pulse input (max 20kHz). |
| AOV-GND, AOI-GND | Analog Output 1 | Output voltage range: 0-10V. Output current range: 0-20mA, 4-20mA (optional). |
| FM-GND | High-speed Pulse Output | Max frequency 20kHz. Can also be used as an open collector output. |
| TA-TB-TC | Relay Normally Open Terminal | Contact drive capability: AC250V, 3A, cosφ=0.4; DC30V, 1A. |
| A+, B- | RS-485 Communication | A+ is differential positive input, B- is differential negative input. |
5. Operation Display
The operation panel allows you to modify function parameters, monitor the inverter's working status, and control its operation (start, stop).

Figure 5.1: Operation Panel Layout
5.1 Function Indicators
- RUN: Light off indicates stop state; light on indicates running state.
- LOCAL/REMOT: Indicates keyboard, terminal, or communication control.
- FWD/REV: Indicates forward or reverse rotation.
- TUNE/TC: Tuner/torque control/fault indicator.
5.2 Digital Display Area
The 5-digit LED display shows set frequency, output frequency, monitoring data, and alarm codes.
5.3 Keyboard Button Functions
| Key | Name | Function |
|---|---|---|
| PRG | Programming key | Enter or exit the first level menu. |
| ENTER | Enter | Enter menu screen step by step, confirm settings. |
| ▲ | Increment key | Increment data or function code. |
| ▼ | Decrement key | Decrement data or function code. |
| ► | Shift key | Select modification position of parameter when counting. Cycle display parameters in stop/running interface. |
| RUN | Run key | Used to run operation in keyboard mode. |
| STOP/RES | Stop / reset | Stops running operation. Resets fault alarms. |
| MF.K | Multi-function selection key | Selects function switch according to P7-01. |
6. Function Parameter Table
The inverter features a comprehensive set of function parameters organized into groups (P0-PF, A0-AF, U0). These parameters control various aspects of the inverter's behavior, including motor control, input/output settings, and communication. For a complete and detailed list of all function parameters and their descriptions, please refer to the official PDF manual, Chapter 4: Function Parameter Table (pages 10-36).
7. Fault Diagnosis and Countermeasures (Troubleshooting)
The YL586K inverter has 24 warning messages and protection functions. When a fault occurs, the protection function activates, the inverter stops output, the fault relay acts, and the fault code is displayed on the panel. Before seeking service, perform self-examination using the guidelines below.
7.1 Common Faults and Solutions
| Fault Name | Fault Code | Trouble Shooting | Troubleshooting Countermeasures |
|---|---|---|---|
| Inverter unit protect | Err01 | Short circuit of inverter output circuit; Wiring of motor and inverter too long; Module overheated; Internal wiring loose; Main control board abnormal; Drive board abnormal; Inverter module abnormality. | Eliminate peripheral faults; Install reactor or output filter; Check air duct and fan; Plug in all connecting wires; Seek technical support. |
| Accelerating overcurrent | Err02 | Grounding or short circuit in output; Control mode vector, no parameter identification; Acceleration time too short; Manual torque boost/V/F curve inappropriate; Low voltage; Start rotating motor; Sudden load during acceleration; Inverter selection too small. | Eliminate peripheral faults; Perform motor parameter identification; Increase acceleration time; Adjust manual lifting torque or V/F curve; Adjust voltage; Choose speed tracking start; Cancel sudden load; Choose higher power frequency converter. |
| Deceleration overcurrent | Err03 | Grounding or short circuit in output; Control mode vector, no parameter identification; Deceleration time too short. | Eliminate peripheral faults; Perform motor parameter identification; Increase deceleration time; Adjust voltage. |
| No display after power-on | N/A | Grid voltage not or too low; Switching power supply on drive board faulty; Rectifier bridge damaged; Buffer resistance damaged; Control panel/keyboard wiring faulty. | Check input power, bus voltage; Seek service from manufacturers; Replace keyboard cable or contact manufacturer. |
| Electric machine does not rotate | N/A | Motor wire not connected properly; Inverter parameter setting error; Bad connection between drive board and control board; Drive board failure. | Reconfirm connections; Replace motor; Clear mechanical fault; Check and reset motor parameters. |
For a complete list of fault codes, detailed troubleshooting steps, and advanced diagnostics, please refer to Chapter 5: Fault Diagnosis and Countermeasures in the official PDF manual (pages 37-42).
8. User Tips
- Versatile Application: The VFD's triple output type and various input/output voltage/power options make it suitable for a wide range of applications, including CNC engraving and milling.
- Compact Design: With dimensions of 110x85x145mm and a weight of 1kg, it's designed for efficient space utilization.
- Frequency Control: The 0-3200Hz output frequency range allows for precise control over spindle speed, which is beneficial for detailed CNC work.
- Voltage Conversion: The inverter can convert 110V to 220V, making it adaptable for different power requirements.
9. Warranty and Support
The HLTNC YL586K Vector VFD Inverter comes with a 12-month warranty from the date of manufacture and delivery, as indicated by the barcode on the fuselage. During this period, if the product fails or is damaged under normal use and according to the instruction manual, HLTNC is responsible for free maintenance.
A maintenance fee will be charged for damages caused by:
- Mistakes in use, unauthorized repairs, or alterations.
- Damage from fire, flood, abnormal voltage, natural disasters, or secondary disasters.
- Hardware damage due to artificial drop or transportation after purchase.
- Operation not in accordance with the user manual.
- Failure or damage caused by external equipment factors.
For full warranty details and conditions, please refer to the 'Warranty Agreement' section in the official PDF manual (page 57).
10. Quality Assurance
HLTNC has been engaged in the CNC industry for 13 years, with mature experience in product production, processing, and sales. They offer comprehensive pre-sales service and after-sales technical support.
Video 10.1: HLTNC Company Overview and Manufacturing Process
11. Additional Resources
For the complete user manual with detailed function parameter tables, communication protocols, and advanced troubleshooting, please download the official PDF document: