User Manual: diymore XY-CD63L Battery Charging Control Module

Models: CD60L 10A, CD63L 30A

1. Introduction

This manual provides detailed instructions for the diymore XY-CD63L Battery Charging Control Module, available in 10A (CD60L) and 30A (CD63L) versions. This module is designed to protect batteries from undervoltage and overvoltage conditions during charging and discharging cycles, effectively extending battery life. It features a liquid crystal display for voltage, percentage, and time, and is suitable for use with any battery type (including lithium) within a 6-60V range.

diymore XY-CD63L Battery Charging Control Module with LCD display
Figure 1: diymore XY-CD63L Battery Charging Control Module (30A version) showing dual mode functionality, large current 30A relay, 6-60V compatibility, and liquid crystal display for voltage, percentage, and time.

2. Safety Warnings

  • Ensure correct polarity when connecting the module to the battery and charger/load to prevent damage.
  • Do not exceed the specified voltage range (6-60V) or current rating (10A for CD60L, 30A for CD63L) to avoid module failure or battery damage.
  • High current charging can cause battery overheating, accelerated aging, bulging, or even explosion. Always use appropriate charging currents (typically 1/10 to 1.5 times the battery capacity).
  • This product is a voltage controller and acts as a switch; it does not regulate voltage or limit current. Ensure your charger provides the correct voltage and current for your battery.
  • Installation should be performed by individuals familiar with electronics and battery systems.

3. Product Overview

The module features a liquid crystal display (LCD) showing real-time battery voltage, charge/discharge percentage, and operational time. It includes three control buttons: UP, SET, and DOWN, for parameter configuration and mode switching. A relay closing indicator LED provides visual feedback on the relay's status.

Angled view of the XY-CD63L module showing the LCD, relay, and control buttons.
Figure 2: Angled view of the XY-CD63L module, highlighting the LCD screen, the 30A relay, and the UP, SET, and DOWN buttons.

4. Specifications

AttributeValue
Brand Namediymore
Model NumberXY-CD63L (also CD60L)
TypeVoltage Regulator
Supply Voltage6-60V DC
Dissipation Power (CD63L)30A
Dissipation Power (CD60L)10A
Operating Temperature30A battery charging control module
ApplicationComputer (general electronic control)
PackageSOP
is_customizedYes
ConditionNew
OriginMainland China

Dimensions and Weight

Product size chart for XY-CD63L module
Figure 3: Dimensions of the XY-CD63L module: 62mm (length) x 57mm (width), height 22mm, weight 51g.
Product size chart for XY-CD60L module
Figure 4: Dimensions of the XY-CD60L module: 45mm (length) x 46mm (width), height 20mm, weight 25g.

5. Setup and Wiring

The module operates in two main modes: Charging (IN) and Discharging (OUT). Proper wiring is crucial for safe and effective operation.

5.1 Charging Mode Wiring (IN)

In charging mode, the module controls the charger's connection to the rechargeable battery. The charger input (DC6~60V) connects to the VIN+ and VIN- terminals. The rechargeable battery connects to the OUT+ and OUT- terminals. The module will display 'IN' when in charging mode.

Wiring diagram for charging mode (IN) for XY-CD63L
Figure 5: Charging mode wiring diagram for the XY-CD63L module. Connect the charger to VIN+ and VIN-, and the rechargeable battery to OUT+ and OUT-. The display shows 'IN' during charging.
Wiring diagram for charging mode (IN) for XY-CD60L
Figure 6: Charging mode wiring diagram for the XY-CD60L module. Similar connections as CD63L, with the display showing 'IN' and battery voltage/percentage.

5.2 Discharge Mode Wiring (OUT)

In discharge mode, the module controls the load's connection to the rechargeable battery. The rechargeable battery connects to the VIN+ and VIN- terminals. The load connects to the OUT+ and OUT- terminals. The module will display 'OUT' when in discharge mode.

Wiring diagram for discharge mode (OUT) for XY-CD63L
Figure 7: Discharge mode wiring diagram for the XY-CD63L module. Connect the rechargeable battery to VIN+ and VIN-, and the load to OUT+ and OUT-. The display shows 'OUT' during discharge.
Wiring diagram for discharge mode (OUT) for XY-CD60L
Figure 8: Discharge mode wiring diagram for the XY-CD60L module. Similar connections as CD63L, with the display showing 'OUT' and battery voltage/percentage.

5.3 Battery Undervoltage Protection Example

This diagram illustrates how the module can be used for battery undervoltage protection, connecting a battery to the module and a USB intelligent load to the output.

Battery undervoltage protection wiring diagram with USB intelligent load
Figure 9: Example wiring for battery undervoltage protection. A rechargeable battery is connected to the module, which then powers a USB intelligent load. The module disconnects the load if the battery voltage drops below a set threshold.
Physical wiring chart of battery charging control connection with USB desktop tools
Figure 10: Physical wiring chart demonstrating battery charging control using the module and a USB desktop tool for constant voltage and current charging of small rechargeable batteries.

6. Operating Modes and Button Functions

6.1 Charging Mode (IN)

In this mode, the module controls battery charging. Set an upper limit voltage (UP) and a lower limit voltage (dn). When the battery voltage falls below or equals 'dn', the relay turns on, and the charger begins charging. When the battery voltage reaches or exceeds 'UP', the relay disconnects, completing the charging cycle. The display will show 'IN' and flash to indicate active charging.

6.2 Discharge Mode (OUT)

In this mode, the module controls battery discharging (undervoltage protection). Set an upper limit voltage (UP) and a lower limit voltage (dn). When the battery voltage is greater than or equal to 'UP', the relay turns on, allowing the load to draw power. When the battery voltage drops to or below 'dn', the relay disconnects, stopping the discharge. The display will show 'OUT' and flash to indicate active discharging.

6.3 Button Functions

  • UP button: Short press to switch the display between percentage (%) and time. Long press for 5 seconds to switch between Charging (IN) and Discharge (OUT) modes.
  • SET button: Short press to view the currently set parameters (UP, dn, OP, dOP, FOP). Long press to enter the parameter setting interface.
  • DOWN button: Short press to turn off/on the relay enable (emergency stop function). When disabled, the LCD display turns OFF, and the relay is disconnected. Long press to set the status of the LCD backlight (L-P): 'OFF' for always on, 'ON' for automatic turn-off after 5-10 minutes (any key press will wake it up).

7. Parameter Settings

  1. Press and hold the SET button to enter the parameter setting interface.
  2. Once in the setting interface, short press the SET button to cycle through the parameters:
    • UP: Upper voltage limit.
    • dn: Lower voltage limit.
    • OP: Conduction time (0-999 seconds).
    • dOP: Delayed on time (0-999 seconds).
    • FOP: Forced on time in discharge mode (0-10 seconds).
  3. After selecting a parameter, use the UP and DOWN buttons (short press or long press) to adjust its value.
  4. To set other parameters, repeat steps 2 and 3.
  5. After all parameters are set, long press the SET button to exit and save the settings.

7.1 Charge/Discharge Time Control (OP)

If OP is set to a non-zero value, time control is enabled. The timer starts when the relay first turns on. Upon completion of the set time, the relay automatically disconnects. If, after timing, the voltage conditions (e.g., voltage < dn in charge mode) are not met, the time control function will automatically turn off, and the display will flash 'H:ER' to indicate an unreasonable time setting. Press any key to stop flashing. If time control is not enabled, the module records the total charge/discharge time, which can be viewed by short pressing the UP button. This recorded time is cleared when charging/discharging restarts.

7.2 Automatic Parameter Detection

After setting and exiting parameters, if the lower voltage limit (dn) is set to be greater than or equal to the upper voltage limit (UP), the system will flash 'ERR' as a reminder of an invalid setting.

7.3 Delay Turn-on Function (dOP)

This parameter sets the interval time (in seconds) between completing one charge/discharge cycle and starting the next.

7.4 Discharge Conduction Forced Start Time (FOP)

In discharge mode, after the relay conduction conditions are met, the relay is forced to remain on for a set time (0-10 seconds) to re-detect the battery voltage. This prevents false triggering and premature disconnection if the load causes an instantaneous voltage drop at the moment of connection.

8. Maintenance

  • Keep the module clean and free from dust and moisture.
  • Avoid exposing the module to extreme temperatures or direct sunlight.
  • Regularly check wiring connections for tightness and corrosion.
  • Ensure adequate ventilation around the module, especially when operating at higher currents, to prevent overheating.
  • Do not attempt to repair the module if you are not qualified.

9. Troubleshooting

Q: What voltage range is suitable for this product?

A: This module is suitable for use within a voltage range of minimum 6V and maximum 60V. The maximum battery expenditure level is 48V, as a 48V battery is fully charged at approximately 60V. Using a voltage higher than 60V will damage the module. If your battery is higher than 48V, please choose a different model.

Q: After power-on, the relay clicks repeatedly, and the light flickers.

A: This usually indicates that your charging current is too large or the battery capacity is too small. The battery voltage immediately reaches the upper limit after power-on, causing the relay to disconnect. The voltage then rapidly drops to the lower limit, and charging restarts, creating a cycle. To resolve this, reduce the charging current. A general guideline is that the charging current should be 1/10 to 1.5 times the battery capacity (e.g., for a 20AH battery, the charging current should be around 2-3A). High current charging can lead to battery heating, accelerated aging, bulging, and even explosion.

Q: What control method does this module use? Can it recharge automatically? Can it be charged while in use? Can current be limited?

A: This module uses voltage control. For example, if the lower voltage limit is set to 12.0V and the upper limit to 14.5V, charging will stop at 14.5V and restart when the voltage drops to 12.0V. It can be charged while in use. However, this module only acts as a switch based on voltage thresholds; it cannot limit the current. The charging current is entirely dependent on your charger.

Q: Can I charge a 24V battery with a 12V input, or a 12V battery with a 48V input?

A: No. This is a simple voltage controller that only performs a switching function. It cannot change or convert voltages. You must use a charger that provides the appropriate voltage for the battery you intend to charge.

Q: How can I switch to OUT mode?

A: To switch to OUT (discharge) mode, long press the UP button for 5 seconds. The display will indicate the current operating mode (IN for charging, OUT for discharging).

10. User Tips

  • Read the Manual: While the product is straightforward, understanding the parameter settings and wiring diagrams is crucial for optimal performance and safety. Always refer to this manual or the official website for instructions.
  • Verify Wiring: Double-check all connections, especially polarity, before applying power to prevent damage to the module or battery.
  • Monitor Charging Current: Pay attention to your charger's output and battery capacity to avoid overcurrent situations, which can harm your battery.
  • Parameter Testing: When setting parameters like OP, dOP, and FOP, start with conservative values and adjust gradually to fine-tune performance for your specific application.

11. Warranty and Support

For warranty information, technical support, or further inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

A PDF version of this user manual is available for download: Download User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.