NOYAFA NF-521

Contents

NOYAFA NF-521 Infrared Thermal Imager User Manual

Model: NF-521

1. Safety Precautions

Please read these precautions carefully before operation.

  • This device is powered by a lithium battery. Please fully charge the new product when it is first used.
  • Do not place the device in dusty, humid, or hot locations (above -10~45°C).
  • Use only batteries that meet the specifications to avoid damage.
  • Do not disassemble the device. All repair and maintenance should be performed by professional staff.
  • For long-term storage, remove the battery from the test terminal to prevent battery liquid leakage.

2. Product Overview

The NOYAFA NF-521 is an advanced thermal imaging camera designed to combine surface temperature measurement with real-time thermal imaging. It effectively converts thermal radiation images into visible light images, making it an invaluable tool for various applications.

Primary Applications:

  • Building diagnostics (e.g., floor heating blockage, water leakage detection).
  • Industrial leak detection.
  • Electromechanical testing and maintenance.
  • Automobile maintenance.
  • Firefighting and rescue work.
  • Maintenance of old buildings.
NOYAFA NF-521 Infrared Thermal Imager front and back view

Figure 1: NOYAFA NF-521 Infrared Thermal Imager (Front and Back View)

Dimensions of the NF-521 thermal imager

Figure 2: Device Dimensions (210mm H, 120mm W, 60mm D)

Video 1: NOYAFA NF-521 Product Demonstration. This video showcases the device's features including image fusion, color imaging modes, automatic tracking, and adjustable emissivity.

3. Product Components and Packing List

3.1. Device Components

NF-521 labeled components and features

Figure 3: NF-521 Device Components and Features. Key components include SD card slot, USB interface, UP key, Return key, Down key, OK&Menu key, Thermometer lens, Infrared camera, and Trigger. Features include cold hotspot tracking, rapid temperature capture, image refresh, TF card data transfer, data storage, highly sensitive sensor, 2.4" full view display, and adjustable emissivity.

3.2. Packing List

The standard package includes the following items:

ItemQuantity
NF-521 Infrared Thermal Imager (with 16GB TF card & lithium battery)1
Storage Bag1
USB Data Cable1
Instruction Manual1
Qualification Certification1
NF-521 packaging and included accessories

Figure 4: NF-521 Packaging and Included Accessories

4. Setup Instructions

4.1. Initial Charging

Before first use, ensure the device is fully charged. Connect the Micro USB data cable to the device and a 5V charger. The battery symbol in the upper right corner of the screen will turn green, indicating charging status.

4.2. Power On

Press and hold the power button (green button) for approximately 6 seconds until the welcome interface appears. Release the button to complete startup.

5. Operating Instructions

5.1. Power On/Off

  • Power On: Press and hold the power button (green button) for approximately 6 seconds until the welcome interface appears.
  • Power Off: While the device is on and not in a settings menu, press and hold the power button for approximately 3 seconds until the shutdown confirmation interface appears. Press the OK button (blue button) to confirm shutdown, or the Return button (left arrow button) to cancel.

5.2. Display Modes

The device offers multiple display modes, which can be cycled through using the Up/Down keys:

  • Infrared Mode: Displays only the thermal image.
  • Infrared Edge Detection Mode: Highlights the edges of objects in the thermal image.
  • Dual Light Fusion Mode: Blends visible light and thermal images for enhanced detail.
  • Visible Light Mode: Displays a standard visual image.
Image fusion functions and color imaging modes

Figure 5: Two Image Fusion Functions (Contour and Thermal Imaging Fusion, Visible Light and Thermal Imaging Fusion) and Three Color Imaging Modes (Rainbow, Black and White, Iron Oxide Red).

5.3. Color Palettes

The NF-521 supports various color palettes to visualize temperature differences. These include:

  • Iron Red
  • Cold Color
  • Black Heat
  • Rainbow
  • Red Heat
  • White Heat
  • Lava

5.4. Temperature Measurement

When not in a settings interface, the display shows temperature information:

  • The white center point indicates the temperature value of the specific point.
  • The red dot indicates the maximum temperature on the screen.
  • The green dot indicates the lowest temperature on the screen.
NF-521 in use showing thermal image with temperature readings

Figure 6: NF-521 in use, displaying a thermal image with maximum, minimum, and center point temperature readings.

5.5. Photography

To capture an image, press the trigger button when not in a settings interface. Press the OK button to save the image, or the Return button to discard it.

5.6. Unit Switching

Navigate to the settings menu, select 'Unit', and press OK. Use the Up/Down keys to choose between Celsius (°C), Fahrenheit (°F), or Kelvin (K). Press OK to confirm and Return to exit.

5.7. Emissivity Adjustment

Emissivity represents the thermal reflectivity of an object's surface. For accurate temperature measurements, adjust the emissivity value (0.1-1.0) in the settings menu to match the material being measured.

5.8. Shutter Spacing

The device's shutter spacing helps ensure clear images and accurate temperature measurements. The industrial temperature measurement interval is typically 3 minutes, while the general interval is 1 minute.

5.9. Document Management

Access 'File Management' in the settings menu to view or delete captured pictures and videos. In picture viewing mode, press the trigger to switch between thermal and visible light images. In video viewing mode, press the trigger to play/pause. To delete, select the delete option and confirm.

5.10. Language, Date & Time, Alarm Settings, System Info

These settings can be adjusted via the 'More settings' menu. Use the Up/Down keys to navigate and OK to select/confirm. The alarm setting allows you to define high and low temperature thresholds, triggering a visual alarm (red display) if exceeded.

6. Maintenance

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Battery Care: For prolonged storage, remove the lithium battery to prevent potential leakage and damage to the device.
  • Professional Service: Do not attempt to open or repair the device yourself. Refer all servicing to qualified professional staff.

7. Troubleshooting

  • Inaccurate Temperature Readings: If the measured temperature is not accurate, try moving the device and adjusting the distance from the target to obtain a more precise temperature value.
  • Device Shuts Down Unexpectedly: If the battery symbol turns red, it indicates low power. Charge the device immediately to prevent automatic shutdown.
  • Floor Heating Blockage Detection: When using the iron red mode for floor heating, if the red area disappears along the path, it indicates a blockage.
  • Water Leakage Detection: If the red area appears in pieces, it suggests water leakage.

8. Specifications

CategoryParameterValue
General ParametersDevice Size (L x W x H)60 x 120 x 210 mm
Monitor2.4" TFT LCD
Display Resolution320 x 240 pixels
Battery3.7V / 2600 mAh
Automatic Shutdown FunctionYes
CertificationCE
Drop Proof1M (3.28 inch)
Thermal Imaging TechniqueLanguageChinese/English
Thermal Imaging Resolution32 x 32 (1024 pixels)
Electronic ShutterNo
Visible Light Camera2 megapixels
Display Resolution ModesInfrared edge detection, Dual light fusion, Visible Light, Infrared mode
Color PalettesIron red, Cold color, Black heat, Rainbow, Red heat, White heat, Lava
Infrared Spectral Bandwidth8-14 µm
FOV (Field of View)33° horizontal
IFOV (Instantaneous Field of View)18 mrad
Thermal Imaging Sensitivity150 mk
Frame Rate≤9 Hz
Infrared Temperature MeasurementTemperature Measurement Range-20~400°C
Basic Accuracy0°C to 400°C: ±1.8% or ±1.8°C; -20°C to -0.9°C: ±3°C (Emissivity: 0.95, Ambient Temp: 25±2°C)
EmissivityAdjustable 0.1~0.99
Measuring Resolution0.1°C/°F
Response Time150 ms
Spectral Band8-14 µm

9. Warranty and Support

The product comes with an After-Sales Service Clause and Qualification Certification, as indicated in the packing list. For any issues requiring repair or maintenance, please contact professional service personnel. Unauthorized disassembly or repair may void your warranty.

A detailed user manual in PDF format is available for download: NF-521 User Manual (PDF)

10. User Tips

  • Electrical Component Temperature: Yes, the NF-521 is suitable for seeing the temperature of electrical components, making it useful for electromechanical testing.
  • Under-Tile Water Leak Detection: The device can effectively detect water leaks under tiles, particularly for floor heating systems, by identifying temperature anomalies.
  • Initial Testing: It is recommended to thoroughly test the device upon receipt to familiarize yourself with its functions and ensure optimal performance for your specific applications.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.