1. Introduction
The ELECTESLA ES-P300 Pressure Transmitter is a high-performance device designed for accurate pressure measurement in various industrial applications. It utilizes imported diffused silicon cores, advanced circuit processing, and temperature compensation technology to convert physical pressure parameters into standard electrical signals (4-20mA, 0-5V, 0-10V, RS485).
Its compact, all-stainless steel integrated structure ensures durability and ease of installation. The transmitter is suitable for measuring pressure in liquids, gases, and oils, provided they are compatible with the device's contact materials. It supports gauge pressure, negative pressure, and absolute pressure measurements.
The ES-P300 is equipped with polarity reversal and current limiting protection, laser resistor temperature adjustable degree compensation, programmable adjustment, anti-vibration, anti-shock, anti-radio frequency electromagnetic interference, overload, and strong anti-interference capabilities, making it economical, practical, and stable in performance.
Video: Demonstration of the Herssman Pressure Transmitter, highlighting input, output, and thread types.
2. Safety Notices
WARNING: Failure to follow these instructions may result in equipment damage or personal injury.
- Always check the product label to ensure it matches your ordering parameters.
- Read this instruction manual carefully before use. Contact support for assistance if you have questions.
- Ensure the device is under no pressure and no power when connecting or disconnecting.
- This transmitter uses a diffused silicon oil-filled core. Do not use it in high-temperature or explosion-proof areas to prevent accidents.
- Do not measure media that are incompatible with the transmitter's contact materials. Strictly prohibit measuring oxygen.
- When measuring pressure, slowly increase or release pressure to avoid instantaneous shock, which can damage the sensor.
- Before disassembling, ensure the pressure source and power supply are disconnected to prevent accidents from media spraying.
- No modifications or changes are allowed on the device.
- This product is weak current equipment; wire it separately from strong current cables.
- This product is not explosion-proof equipment. Do not use in explosion-prone areas.
3. Specifications
| Attribute | Value |
|---|---|
| Brand Name | ELECTESLA |
| Model Number | ES-P300 |
| Product Name | ES-P300 Pressure Transmitter |
| Origin | Mainland China |
| Certification | CE, FCC, RoHS |
| Measuring Medium | Water, Gas, Oil, Liquid (compatible with SS316L) |
| Measuring Range | -0.1 ~ 0 ~ 100Mpa (-1bar-0-1000bar, -14psi-0-14500psi customizable) |
| Max Measuring Range | 400 Bar & Above |
| Output Signal | 4-20mA; 0-5V; 0-10V; RS485 (1-5V, 0.4V-4.5V customizable) |
| Power Supply | DC12V; DC24V (5VDC, 12V-24VDC customizable) |
| Accuracy | ≤±0.5%FS (0.2%F.S, 0.5% F.S. default) |
| Overload Capacity | 150% F.S. |
| Response Time | ≤10ms |
| Operating Temperature | -40-85℃ |
| Long-term Stability | ±0.2%F.S./1year |
| Temperature Drift | 0.05%F.S./℃ (-10℃-65℃) |
| Housing Material | 304 Stainless Steel (Customizable SS316) |
| Pressure Connection | M20*1.5, G1/4, G1/2 (M14*1.5, M16*1.5, G1/8, G3/8, NPT1/2, NPT1/4 customizable) |
| Cable | 1M Cable for free |
| Protection Class | IP65 |
| Battery Included | No |
| High-concerned chemical | None |
Note: Some parameters are customizable. Please refer to your specific product configuration.
4. Working Principle
The ES-P300 pressure sensor operates on the principle of a Wheatstone bridge diffused onto a single crystal silicon wafer. When the measured medium (gas or liquid) applies pressure, it causes a change in the resistance of the bridge wall (piezoresistive effect). This generates a differential voltage signal, which is then converted into a standard analog or digital signal by a dedicated amplifier circuit, providing a precise and stable output.
Image: Exploded view of the Pressure Transmitter, showing internal components like the diffusion silicon chip, pure copper core, and PVE engineer plastic.
5. Installation
5.1 General Precautions
- Installation should be performed without pressure and power applied to the system.
- Install the transmitter in locations where temperature gradients are minimal.
- For measuring gases with a range less than 0.03Mpa, the transmitter must be mounted vertically to ensure accuracy. Other ranges can be mounted at any angle.
- In hydraulic systems, mount pressure connections upwards to facilitate easy gas venting.
- If the pressure connection faces upwards or sideways, ensure no liquids flow into the transmitter housing. Moisture and dirt can block atmospheric outlets, potentially causing equipment failure.
- Keep the threaded connection edges of electrical connections free from dust and dirt.
- It is recommended to install a pressure shut-off valve in front of the measurement point for easy access, removal, and to reduce pressure shock during initial setup.
- If the installation site is prone to lightning or over-voltage, protect the transmitter with appropriate lightning arrestors and over-voltage protection at the distribution box or between the power supply and the transmitter.
- Select the appropriate sealing fitting and position. The thread length must be greater than the bottom thread depth to ensure an effective end gasket seal. When using raw tape or seals, ensure a small surplus after locking.
5.2 Wiring Diagram
The ES-P300 supports various output signals, each with a specific wiring configuration. Refer to the diagrams below for correct connections.
Image: Two ES-P300 Pressure Transmitters, showing the cable connection.
Image: ES-P300 Pressure Transmitter highlighting input range (-0.1-0-100Mpa), output (4-20mA, 0-5V, 0-10V), and power (DC24V).
Current Output (4-20mA):
- Red wire: DC24V+
- Blue wire: Current output
Voltage Output (0-5V / 0-10V):
- Red wire: DC24V+
- Blue wire: COM (Common Ground)
- Yellow wire: Voltage output
RS485 Output:
- Red wire: DC24V+
- Blue wire: DC24V-
- Yellow wire: A (RS485 data line)
- Green wire: B (RS485 data line)
6. Operation
Once the ES-P300 Pressure Transmitter is correctly installed and wired, ensure the power supply voltage meets the requirements (DC12V or DC24V, depending on model) and the pressure source is within the transmitter's specified range. Slowly apply pressure to the system. The transmitter will convert the measured pressure into the corresponding electrical output signal (4-20mA, 0-5V, 0-10V, or RS485) which can then be read by secondary instruments or control systems.
The device features an 8-point standard calibration and 4-point detection calibration, ensuring accurate measurements across its full range. Some models may include an LED or LCD display for direct pressure readings.
7. Maintenance
- Before cleaning the pressure transmitter, ensure the pressure is relieved and the device is disconnected from its power source.
- Do not touch the diaphragm with any objects to avoid damage.
- Wipe the surface of the transmitter with a soft, damp cloth. Avoid harsh chemicals or abrasive materials.
- Regularly check the electrical connections for dust and dirt, ensuring they remain clean and secure.
- The sensor is equipped with an internal pulse buffer to handle cavitation, liquid hammer, and peak pressure. While this feature helps, it's still advisable to minimize such occurrences in the system.
- If the device is not functioning as expected, refer to the troubleshooting section or contact technical support. Do not attempt unauthorized repairs or modifications.
8. Troubleshooting
This section provides guidance for common issues. For more complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| No output or incorrect reading | Incorrect wiring; Power supply issue; Pressure range mismatch; Sensor damage. | Verify wiring against diagram; Check power supply voltage; Ensure pressure is within specified range; Inspect for physical damage. |
| Unstable readings | Temperature fluctuations; Pressure shocks (cavitation/liquid hammer); Electrical interference. | Install in stable temperature environment; Use a pressure shut-off valve to mitigate shocks; Ensure proper grounding and separation from strong current cables. |
| Device not powering on | No power supply; Incorrect voltage; Wiring error. | Check power source; Verify power supply voltage matches device requirements; Re-check wiring connections. |
| Incompatible media damage | Exposure to corrosive or incompatible substances. | Ensure only compatible media are measured. Replace damaged unit. |
9. User Tips
- For optimal performance and longevity, consider installing a filter upstream of the transmitter to prevent particulate matter from entering the pressure port.
- Regularly calibrate the transmitter according to your system's requirements to maintain accuracy over time.
- When selecting a customizable option, double-check all parameters (input range, output, thread size, power supply) to ensure they meet your specific application needs.
- Keep the device's serial number and purchase information handy for any warranty claims or technical support inquiries.
10. Warranty & Support
The ELECTESLA ES-P300 Pressure Transmitter is designed for reliable operation. For any technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact ELECTESLA Official Store directly.
You can reach out via:
- Online service (as indicated by the seller)
- WhatsApp: +8615665610693
- Email: sales02@jinqu-electric.com
Please have your product model (ES-P300) and any relevant purchase details ready when contacting support.