ATORCH DT24TW

Contents

ATORCH DT24TW Bidirectional Current Battery Tester User Manual

Model: DT24TW

1. Introduction

This manual provides detailed instructions for the ATORCH DT24TW Bidirectional Current Battery Tester. Please read carefully before use to ensure accurate operation and measurement.

Important statement:

This meter does not immediately display the capacity of the connected battery as soon as it is powered on. After receiving the goods, it is necessary to strictly follow the instructions in the manual for a series of operations in order to accurately display the actual capacity of the connected battery! If you are a novice user, please read the manual carefully or call the manufacturer's technical personnel for help.

ATORCH DT24TW Battery Tester Overview
Figure 1: ATORCH DT24TW Battery Tester Overview. Shows the main display unit and the shunt module with connections.

2. Specifications

The ATORCH DT24TW is a bidirectional current type high-definition color screen Bluetooth digital curve version battery capacity monitor. It supports charging and discharging and is suitable for various applications.

2.1. Scope of Application

This instrument is suitable for electric vehicles, RVs, cars, emergency power supplies, energy storage power supplies, measuring equipment, medical equipment, various instruments and other products that use battery equipment.

It is suitable for all types of battery packs, including lithium batteries, lithium iron phosphate, lead-acid batteries, nickel hydrogen batteries, etc., with operating voltages ranging DC 8~240V.

2.2. Product Parameters

Parameter Value
Brand Name ATORCH
Model Number DT24TW
DIY Supplies Electrical
Power Supply DC
Display Type Analog and Digital
Measurement Voltage Range 8-240V
Measurement Current Range 0.1-100A / 0.1-200A / 0.2-300A / 0.3-400A / 0.4-500A / 0.5-600A / 1-1000A (depending on shunt)
Measurement Power Range 0-100KW / 200KW / 300KW / 400KW / 500KW / 600KW / 1000KW (depending on shunt)
Measurement Capacity Range 0-99999AH
Support Bluetooth Yes
Bidirectional Current Support Charging and discharging
Panel Size (L x W) 85.7mm x 63mm
Panel Installation Size (L x W) 75.8mm x 52.6mm
External Shunt Board Size (L x W) 58.5mm x 54mm
DT24TW Instruction Manual First Page
Figure 2: DT24TW Instruction Manual First Page. Displays the device screen and shunt module, highlighting key features and ranges.
DT24TW-100A Bidirectional Current and Voltmeter Components
Figure 3: DT24TW-100A Bidirectional Current and Voltmeter Components. Shows the main unit, shunt, 3-meter cable, and 0.4-meter temperature probe.
Mobile Phone Wireless Bluetooth Firmware Upgrade
Figure 4: Mobile Phone Wireless Bluetooth Firmware Upgrade. Illustrates the device display during an upgrade and the corresponding mobile app interface.

3. Package Contents

The package typically includes the following items. Please check your specific model variant for exact contents:

  • DT24P-XXXA Bidirectional Current and Voltmeter (1 pc) - where XXXA corresponds to the selected current range (e.g., 100A, 200A, 300A, 400A, 500A, 600A, 1000A)
  • 3-meter data cable (1 pc)
  • 0.4-meter temperature probe (1 pc)

4. Safety Warnings

  • Always ensure proper wiring connections before powering on the device to prevent damage or injury.
  • Do not exceed the specified voltage and current ranges of the device.
  • Keep the device away from water, moisture, and extreme temperatures.
  • Do not attempt to disassemble or modify the device, as this may void the warranty and pose safety risks.
  • Handle the battery connections with care to avoid short circuits.

5. Installation Instructions

To install the panel unit:

  1. Dig out a rectangular hole according to the panel installation dimensions provided in the specifications.
  2. Tear off the double-sided adhesive tape and white paper strip around the back of the panel.
  3. Directly insert the panel into the rectangular hole.
  4. Press the edges firmly to ensure the adhesive sticks securely to the panel. The installation is complete.
Panel and Shunt Dimensions Diagram
Figure 5: Panel and Shunt Dimensions Diagram. Provides detailed measurements for panel and shunt installation.

6. Wiring Instructions

Attention:

Please strictly follow the wiring diagrams below. The sampler must be connected in series in the negative(-) circuit of the battery, and the shunt must not be connected in the positive(+) circuit! The length of the data cable to the panel can be customized and increased as needed, without affecting data transmission and measurement accuracy.

6.1. General Wiring Diagram

DT24TW Wiring Diagram DC8-240V
Figure 6: DT24TW Wiring Diagram for DC8-240V. Illustrates the connections between the battery, sampler, and display panel.
  1. The sampler provided with this meter must be connected in series to the negative circuit of the battery pack. Connect the B- on the sampler to the negative B- of the battery pack. Connect the negative electrode P-/C- for charging and discharging at the P- end.
  2. Take a thin red wire to connect the positive terminal of the battery to sampler B+, which is used to supply power to this meter and display voltage sampling.
  3. Connect the sampler to the control panel using a randomly distributed data cable. Once confirmed to be correct, power on to display normally.
  4. Wiring principle: It is essential to ensure that all current flowing through the battery passes through the sampler and the shunt on top!

Warning:

The wire from battery pack B- to sampler B- should be as short as possible, as thick as possible, and the voltage drop should be as small as possible to ensure more accurate measurement!

6.2. Battery Discharge Wiring Diagram

Battery Discharge Wiring Diagram
Figure 7: Battery Discharge Wiring Diagram. Shows how to connect the battery tester for monitoring battery discharge with a load.

6.3. Battery Charging Wiring Diagram

Battery Charging Wiring Diagram
Figure 8: Battery Charging Wiring Diagram. Shows how to connect the battery tester for monitoring battery charging with a charger.

7. Operation

7.1. Main Description and Key Operation Method

Analysis of DT24TW Technical Details
Figure 9: Analysis of DT24TW Technical Details. Labels the components and controls of the device.
  • Connect to battery positive(+)
  • Current sampler
  • Battery temperature probe (wire length 1m): Needs to stick to the battery surface to measure the temperature.
  • Bidirectional Current Shunt: Connects to the negative pole of the charging or the negative pole of the device.
  • Connect to battery negative(-)
  • Panel cable (3 meters long)
  • Bluetooth indicator
  • Value + key: Short press to add or long press for 5 seconds to fill up the battery capacity.
  • Mode and setting keys (M): Long press to enter the background settings, short press to switch the menu when in the background.
  • Value - key: Short press to subtract or long press for 5 seconds to subtract zero battery capacity.
  • Power button (ON/OFF): Long press to pop up the reset menu, then short press to switch the menu. When a menu turns purple, press and hold again to execute the menu.
  • 2.4-inch high-definition digital color display: Shows four operating states.

7.2. Usage Steps

  1. Connect and check the current: After completing the connection according to the wiring instructions, power on. The screen should display the battery voltage, current, and factory default capacity percentage. If there is no display, power off and check if the connection is correct. Then, discharge or charge the battery and check if the displayed current value is consistent with the actual current value. If there is a large error, please check the wiring again for correctness.
  2. Inspection and setting of effective battery capacity: The effective capacity of the battery needs to be set correctly for the first use. If the effective capacity of the battery is not accurate, follow these steps:
    1. Long press the "M" key to enter the settings background interface, then short press the "M" key until the second item turns purple. Use the "+" or "-" buttons to adjust the capacity value. Try to set the value as high as possible (e.g., if the estimated tested battery is 200Ah, set this meter to 250Ah).
    2. Empty the battery pack and reset the capacity of the battery gauge by long pressing the "-" key for 5 seconds, then charge the battery pack.
    3. Set the capacity value displayed after the battery is fully charged to the second capacity setting column in the background of this meter to complete the effective setting.
  3. Capacity reset (battery capacity reset and full capacity setting): If the capacity value displayed is not the actual value or if zero/full capacity operation is required (total capacity value in the background should match the tested battery):
    1. After emptying the battery, press and hold the "-" button for 5 seconds to reset the capacity value to 0%.
    2. After fully charging the battery, press and hold the "+" button for 5 seconds to set the capacity value to 100%. (The total full capacity value is the value set in the background).

Warning:

It is necessary to align the measured battery capacity parameters with this meter according to the steps to ensure the accuracy of the battery capacity values and percentages on this meter!!!

7.3. Use Settings (Menu Navigation)

Long press the "M" button to enter the background settings interface, then short press the "M" button to switch the settings section. If there is a flashing number, short press the "+"/ "-" button again to adjust the number. Long press the "+"/ "-" button at this time to adjust the flashing number by advancing or retreating.

ATORCH DT24TW Menu Screen
Figure 10: ATORCH DT24TW Menu Screen. Displays the various settings options available.

The menu items include:

  • Effective capacity of battery: The default value at the factory is 100Ah. Set it according to the actual effective capacity of the battery pack, otherwise the capacity value and battery percentage displayed will be inaccurate.
  • Full capacity voltage: When the voltage is higher than this, the capacity value automatically reaches 100%.
  • Zero capacity voltage: When the voltage value is lower than this, the capacity value will automatically set to 0%. If discharge continues, an alarm will be displayed and beeped.
  • Low capacity alarm: When the capacity is lower than this, the alarm interface pops up and the horn beeps (every 3 minutes).
  • Low voltage alarm: When the voltage is below this level, the alarm interface pops up and the horn beeps (every 3 minutes).
  • Factory reset: Restore all data to factory settings (short press the M key to this column, then long press the "+" key for 3 seconds to reset the system).

Pay attention to the order of events:

The factory default for full capacity voltage and zero capacity voltage is 0V, which is invalid. Do not set these two options without understanding the voltage characteristics of the battery pack (full charge voltage and discharge voltage). If you have accurate battery total capacity, zero capacity voltage, and full capacity voltage, simply set the parameters in the background.

7.4. Simple Tips for Setting Battery Capacity

There are two situations for setting battery capacity:

  1. Known measured battery capacity: Set the known measured battery capacity (in AH) directly in the background of this meter.
  2. Unknown battery capacity: When the capacity of the battery being tested is unknown, the capacity value displayed after fully charging or discharging the battery once can be set to this meter to complete the synchronization and alignment of the battery capacity value.

7.5. System Shutdown and Current Reset Interface Usage

Long press the "ON/OFF" button to enter the interface shown below. Then short press the "M" button to change color and switch to the settings section, and then long press to execute the section.

Zero-power Shutdown and Low-power Standby Brightness Adjustable Mode
Figure 11: Zero-power Shutdown and Low-power Standby Brightness Adjustable Mode. Shows the menu for shutdown and reset options.
  • 01 No load current clearing (Do n--00.00A): When the product still displays a current value when unloaded, press and hold the button to reset the current to "0A". (Do not operate reset when there is load).
  • 02 System shut down: To avoid power loss when the battery is not used for a long time, the system can be shut down and enter zero power mode. Do not shut down when passing current to avoid the significant risk of incorrect display on the meter and actual battery capacity.
  • 03 System reset: In case of system instability or data disorder, perform this operation to restore the system to its factory default value. After resetting, all parameters such as the capacity of the battery that you have already set will be cleared. Please be cautious when operating this item.
  • 04 Exit: Exit and return to the main measurement interface.

8. User Initiated Calibration

When setting up the interface in the background, long press and hold the "+/-" keys simultaneously to enter the user calibration mode. Short press the "M" key to change color and switch columns. The color change will be displayed in the no-load current reset column. Short press the "+/-" keys to perform current reset. The color change will be displayed during voltage and current calibration. Short press the "+/-" keys to adjust the calibration coefficient so that the calibrated voltage and current are the same as the displayed value of the user's own standard instrument.

No-load Current Clearing
Item Before Calibration Calibration Coefficient After Calibration
Voltage Calibration 12.1444V X 01.0100 = 12.1444 V
Current Calibration 00.1076A X 00.9565 = 00.1076 A

9. Connecting to Mobile App via Bluetooth

The device supports wireless connection to a mobile app via Bluetooth for remote control, settings, and detailed measurement data.

9.1. Apple Mobile APP (iOS)

Please search for E_test in the Apple App Store to download and install. Then, click the Bluetooth APP icon to open the software, and click the Bluetooth icon within the app to select DL24-BLE to connect. This allows for remote wireless control, measurement functions, viewing discharge status, data cleaning, and voltage/current power curves.

9.2. Android Phone APP (Android 5.0 and above)

Scan the QR code on the back of the host to download the corresponding APP software, or search for E-test at Google Play. After installation, open the software and click the Bluetooth icon to directly select DL24-BLE to successfully use it online. (No need for Bluetooth pairing; the software Bluetooth icon directly selects DL24).

Android APP Download Address: http://www.mediafire.com/folder/31bc15uhq8odb/E-meter

Mobile APP Interface Function Introduction
Figure 12: Mobile APP Interface Function Introduction. Shows the app's main screen and connection process.

9.3. How to Find the Bluetooth Symbol in E-Test APP

This operating instruction applies to all the company's Bluetooth products (UD18/DT24/DL24/AT3010/DPT3010/T18... etc.).

Please open your phone settings: Settings >> Apps >> Manage Permissions >> Location >> Find E-test app >> Find storage information and location information >> Open permissions (Allow). You can then find the Bluetooth symbol in the E-test list.

How to Find Bluetooth Symbol in E-Test App
Figure 13: How to Find Bluetooth Symbol in E-Test App. Illustrates the necessary phone settings to enable Bluetooth functionality for the app.

10. Troubleshooting

  • Display only shows voltage, no other parameters: Ensure all wiring connections, especially the shunt and data cable, are correct and secure. Verify that current is actually flowing through the shunt. Check the capacity settings as described in Section 7.2.
  • Device does not power on or display anything: Check power supply connections. Ensure the battery is connected correctly and providing sufficient voltage within the device's operating range (DC 8-240V).
  • Inaccurate readings: Verify all wiring is correct and tight. Ensure the sampler is in series with the negative circuit. Perform user calibration as described in Section 8. Check the effective battery capacity settings (Section 7.2) to ensure they match your battery.
  • Bluetooth connection issues: Ensure Bluetooth is enabled on your mobile device. Grant all necessary permissions to the E-test app (Location, Storage) as described in Section 9.3. Make sure the device's Bluetooth indicator is active.
  • Can the device handle charging and discharging simultaneously? Yes, the DT24TW is designed for bidirectional current measurement, supporting both charging and discharging monitoring. The display will show the current state and relevant parameters.
  • Can I switch views on the display between charging and discharging? The device's menu system (accessed via the 'M' key) allows navigation through various parameters and operating states, which includes monitoring both charging and discharging data.

11. User Tips

  • Optimal Wiring: For the most accurate current measurements, keep the wire connecting the battery's negative terminal (B-) to the sampler's B- terminal as short and thick as possible to minimize voltage drop.
  • Cable Extension: The data cable connecting the sampler to the display panel can be extended if needed without affecting data transmission or measurement accuracy.
  • Initial Setup: When using the device for the first time or with a new battery, carefully follow the steps for setting the effective battery capacity (Section 7.2) to ensure accurate percentage and capacity readings.
  • Regular Calibration: If you have a trusted reference meter, periodically perform the user-initiated calibration (Section 8) to maintain the highest accuracy for voltage and current readings.
  • App Permissions: If experiencing issues with the mobile app, always double-check that the E-test app has all required permissions (especially location and storage) enabled in your phone's settings.
  • Monitoring Multiple Batteries: The device is suitable for monitoring battery packs, implying it can be used with systems containing more than one battery, provided the total voltage and current are within the device's specifications.

12. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Avoid dropping or subjecting the device to strong impacts.
  • Firmware Updates: Periodically check for firmware updates via the mobile app (Section 9) to ensure optimal performance and access to new features.

13. Warranty and Support

For further assistance, technical support, or warranty information, please refer to the official product guide and other documentation provided by the manufacturer.

A comprehensive product guide is available in PDF format: Product Guide PDF.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.