Gaqqee DC DC Automatic Boost Buck Converter

Contents

Gaqqee DC DC Automatic Boost Buck Converter CC CV Power Module

User Manual

1. Introduction

This manual provides detailed instructions for the Gaqqee DC DC Automatic Boost Buck Converter CC CV Power Module. This versatile module functions as an adjustable regulated power supply with an integrated voltmeter, offering both constant current (CC) and constant voltage (CV) modes. It is available in two versions: a 3A 35W model without a fan and a 4A 50W enhanced model with a fan for improved heat dissipation. The module features an LCD display, a large volume heat sink, anti-reverse input connection, and anti-backflow output protection.

Gaqqee DC DC Automatic Boost Buck Converter module
Gaqqee DC DC Automatic Boost Buck Converter CC CV Power Module

2. Safety Information

Please read and understand all safety precautions before operating the module. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

  • Ensure proper wiring and connections before applying power.
  • Do not exceed the maximum input voltage, output voltage, or current ratings specified in the technical parameters.
  • Avoid short circuits at the output terminals.
  • Keep the module away from moisture and extreme temperatures.
  • The module features input anti-reverse connection, meaning reverse connection of the input will not burn out the module.
  • The module also features output anti-backflow, eliminating the need for an additional anti-backflow diode when charging a battery.
  • For the enhanced version with a fan, ensure the fan is not obstructed to allow for proper cooling.
Diagram showing input anti-reverse connection feature
Input anti-reverse connection feature

3. Product Overview

The module is designed for precise voltage and current regulation. It includes an LCD display for real-time monitoring and intuitive controls for adjustment and settings.

3.1 Key Features

  • Adjustable output voltage and current.
  • Integrated voltmeter for input and output monitoring.
  • LCD display for clear information readout.
  • Large volume heat sink for efficient cooling.
  • Optional cooling fan for enhanced versions (4A 50W).
  • Protective housing.
  • Input anti-reverse connection protection.
  • Output anti-backflow protection (no external diode needed for battery charging).
  • Switchable display language (Chinese/English).
  • Power-on default ON/OFF setting.
  • Timing switch function.
Product overview highlighting key features like language switch, timer, anti-reverse, and power on/off default
Product overview with key features

3.2 Interface Description

Detailed interface description with numbered labels for VIN, VOUT, SET, ON/OFF, CV, CC, and display elements
Module Interface and Display Elements
  1. Vin: Input voltage value.
  2. Out: Output voltage value.
  3. Cur: Output current value.
  4. Pow: Output power value.
  5. C/F: Temperature value (unit can be set).
  6. Indicator: Green light indicates output switch is ON; red light indicates current limit is active.
  7. Timer: Displays timing time.
  8. Timing: Timer switch.

4. Specifications

ParameterRegular VersionEnhanced Edition
Input Voltage7V-32V
Output Voltage0.5V-32V (Weak output capability below 1.8V)
Output CurrentNormal cooling 3AEnhanced heat dissipation up to 4A
Output Power35W natural coolingEnhanced cooling 50W
Voltage Resolution0.01V
Current Resolution0.001A
Technical Parameters table for regular and enhanced versions
Technical Specifications

4.1 Dimensions

The module dimensions are approximately 7cm (2.76in) in length, 5cm (1.97in) in width, and 3.33cm (1.31in) in height.

Product dimensions diagram showing length, width, and height
Product Dimensions

5. Setup Instructions

5.1 Wiring

Connect your power source to the VIN+ and VIN- terminals. Connect your load to the VOUT+ and VOUT- terminals. Ensure correct polarity for all connections. The module is designed with input anti-reverse connection protection.

5.2 Initial Configuration

Upon first power-on, you may need to configure basic settings such as language and power-on behavior.

  • Language Setting: The module supports switching between Chinese and English. Navigate to the 'Set Page' and select the 'Ch-E' option to change the language.
  • Power-on Default: You can set whether the module's output is ON or OFF by default when powered on. Access this option in the 'Set Page' under 'Open'.
Screenshot of Set Page showing language option
Language Setting on 'Set Page'
Screenshot of Set Page showing power on/off default option
Power-on Default Setting on 'Set Page'

6. Operating Instructions

6.1 Button Functions

Button ActionOther InterfacesSet Interface
ON / OFF short pressSwitchgear (Toggle output ON/OFF)Switch setting data
ON / OFF long pressN/AExit setup options and save
SET short pressSwitch display pagesEnter setting option for switching data effect
SET long pressN/AEnter setup options
CC (Rotate left and right)Adjust current limiting currentAdjust current limiting current
CV (Rotate left and right)Adjust output voltageAdjust output voltage
Key Function table for button actions
Key Function Table

6.2 Menu Navigation and Settings

Press the SET button (short press) to cycle through different display pages. Long press SET to enter the setup options ('Set Page').

Screenshot of Set Page menu options
Set Page Menu Options
  1. Language: System language setting (Chinese/English).
  2. Switch: Power-on default switch settings (Output ON/OFF).
  3. Temperature: Temperature unit setting (°C/°F).
  4. Timing: Output power value.
  5. Time: Timer function switch and time setting.

6.3 Adjusting Voltage and Current

Use the CV potentiometer to adjust the output voltage and the CC potentiometer to adjust the current limiting current. Rotate left or right to decrease or increase the respective values.

6.4 Timing Function

In the 'Set Page', select the 'Time' option. You can set a specific time after which the module will automatically flip its current power switch state (e.g., turn off if it was on, or turn on if it was off). Once the time is set and the timer is enabled, the module will execute the action when the set time arrives.

Screenshot of Set Page showing timing switch option
Timing Switch Setting

6.5 Waveform Display

The 'Waveform Page' displays real-time output voltage and current waveforms.

  • Green indicates output voltage.
  • Blue indicates output current.
  • The top value represents the maximum value in the displayed waveform.
  • The bottom value represents the minimum value in the displayed waveform.
Screenshot of Waveform Page display
Waveform Page Display

6.6 Output Overvoltage Protection (OVP)

The module includes an adjustable Output Overvoltage Protection (OVP) feature. The OVP range is 1.8V-32V, with a default setting of 32V. This can be customized to prevent damage to your load from excessive voltage.

Screenshot of Use Limit page showing Vout, Vin, Cur ranges and OVP setting
Use Limit Page with OVP Setting

7. Maintenance

To ensure optimal performance and longevity of your power module, follow these maintenance guidelines:

  • Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Cooling: The module is equipped with a large heat sink. For the enhanced version, a cooling fan is included. Ensure that the heat sink fins and fan (if present) are not obstructed to allow for proper airflow and heat dissipation.
  • Housing: The module comes with a protective housing. Avoid disassembling the housing unless necessary for advanced modifications or repairs by qualified personnel.
Detailed views of the module, including the cooling fan in the enhanced version
Module details showing cooling components

8. Troubleshooting

  • No Output: Check input voltage connections and ensure they are within the specified range (7V-32V). Verify that the output is enabled (ON/OFF switch).
  • Incorrect Voltage/Current: Use the CV and CC potentiometers to adjust the output to the desired values. Ensure your multimeter is calibrated if verifying readings.
  • Module Overheating: Check for obstructions around the heat sink and fan (if applicable). Ensure the load is not exceeding the module's maximum power or current ratings.
  • Display Issues: If the display is blank or erratic, check power connections. Try cycling the power.
  • Module not responding to buttons: Ensure the module is powered correctly. If in 'Set Interface', a long press of ON/OFF exits and saves settings.

9. User Tips

  • Input Connection: Note that this module uses screw terminals for input (VIN+/VIN-), not a Type-C input.
  • Battery Charging: The built-in anti-backflow protection means you do not need an external diode when using this module to charge batteries, simplifying your setup.
  • Language Preference: Easily switch the display language between Chinese and English via the 'Set Page' for better usability.
  • Power-on State: Configure the module to power on with the output either ON or OFF by default, depending on your application needs.
  • Monitoring: Utilize the waveform display page to visually monitor output voltage and current stability, which can be helpful for sensitive applications.

10. Warranty and Support

This product is CE certified, indicating compliance with European safety, health, and environmental protection requirements.

For further detailed instructions, diagrams, or technical support, please refer to the official user manual PDF available from the seller. A PDF version of the user manual is available here.

10.1 Product Video

Watch a short video demonstration of the product:

Play video
Watch video online
Product demonstration video.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.