1. Introduction
Thank you for choosing the Gaqqee PIR Infrared Motion Sensor Switch. This device is designed to provide automatic lighting control, enhancing convenience and energy efficiency in your home or office. It detects human body movement to automatically turn lights on when presence is detected and off after a set delay when no movement is sensed. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure optimal performance and safety.

Figure 1: Gaqqee PIR Infrared Motion Sensor Switch
2. Safety Information
Please read all safety instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Installation should only be performed by a qualified electrician or trained personnel.
- Ensure the power supply is disconnected before installation or maintenance.
- Do not exceed the maximum load power of 40W.
- This device is designed for indoor use only.
- Keep away from water and high humidity environments.
- Do not attempt to disassemble or modify the switch.
- The product operates at high voltage (AC110-240V). Handle with extreme care.
3. Package Contents
Verify that all items are present in the package:
- Human body sensor switch × 1
4. Specifications
| Parameter | Value |
|---|---|
| Name | Human body infrared sensor head (high voltage type) |
| Working Voltage | AC110-240V |
| Shell Size (Height × Diameter) | 37.2mm × 27.5mm |
| Load Power | ≤40W |
| Sensing Distance | 3-5 meters |
| Sensing Angle | 120° |
| Delay Time | 30 seconds |
| Working Temperature | -20°C to 40°C |
| Recommended Hole Size | 20mm |
| Material | Plastic |
| Current | 3A |
| Certification | CCC |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
5. Setup and Installation
Proper installation is crucial for the sensor switch's functionality and safety. Please follow these steps carefully.
5.1. Installation Demonstration

Figure 2: Installation Demonstration
- Ceiling (Top Loading Method):
- Recommended opening: 20mm.
- Sensing distance: 3-5 meters.
- Sensing area: 120°.
- Ensure the installation position allows for a sensing range of at least 3 meters.
- Side Mounting Method:
- Recommended installation height: 1.5 meters above the ground.
- Front sensing range from the wall: less than 5 meters.
- Sensing distance: 3-5 meters.
- Sensing area: 120°.
Important Installation Notes:
- Pay attention to the proper position and angle during installation. Incorrect placement may result in reduced sensing distance or sensitivity.
- When the ambient temperature decreases, the sensing distance will be farther, and the sensitive response will be higher.
- When the ambient temperature increases, the sensing distance will be closer, and the sensitive response will be lower.
- As long as people are within the sensing range, the connected light will continue to operate and stay on.
5.2. Wiring Demonstration

Figure 3: Wiring Diagram
The sensor switch uses a three-wire connection:
- Brown wire: Live line L input (220V input)
- Yellow wire: Live line L output
- Blue wire: Common zero line N (zero line output)
Connect the sensor switch to any lamp or appliance with an electrical load that does not exceed 40W. The two blue wires are connected in parallel inside the sensor head for convenient connection and can be adapted to one or three wires as needed.
5.3. Product Features Overview

Figure 4: Key Features
6. Operating Principles
The PIR Infrared Motion Sensor Switch operates based on detecting infrared radiation emitted by moving bodies. Its behavior varies depending on ambient light conditions and continuous presence.

Figure 5: Working Principle Diagram
- Daytime Operation: In the daytime or when the ambient light is sufficiently bright, the light will not turn on automatically, even if motion is detected. (Note: A 24-hour sensing model, which ignores ambient light, may be available through customization).
- Nighttime Operation (Initial Detection): After people leave the sensing area at night, the connected lights will turn off automatically according to the set 30-second delay time. The lights will turn on automatically again when someone passes by.
- Nighttime Operation (Insufficient Light): In conditions of insufficient light at night, the switch will not automatically turn on if no human characteristics (infrared signature) are detected.
- Nighttime Operation (Continuous Presence): If a person remains within the sensing area for an extended period, the switch will still turn off the light after the 30-second delay time. The light will not stay on indefinitely just because a person is present. For continuous illumination, the person must remain active within the sensing range to re-trigger the sensor.
7. Maintenance
To ensure the longevity and proper functioning of your sensor switch, follow these simple maintenance guidelines:
- Cleaning: Gently wipe the sensor lens with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the sensor.
- Environment: Ensure the installation area remains within the specified working temperature range (-20°C to 40°C) and is free from excessive dust or moisture.
- Obstructions: Periodically check that there are no objects obstructing the sensor's field of view, as this can impair its detection capabilities.
- Power Cycle: If the sensor behaves erratically, try disconnecting the power for a few minutes and then reconnecting it.
8. Troubleshooting
If you encounter issues with your PIR Infrared Motion Sensor Switch, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on when motion is detected. | 1. Insufficient ambient light (daytime mode active). 2. Sensor obstructed. 3. Incorrect wiring. 4. Load power exceeds 40W. | 1. Test in darker conditions. 2. Clear any obstructions from the sensor lens. 3. Verify wiring according to the diagram. 4. Ensure connected appliance is within 40W limit. |
| Light stays on continuously. | 1. Continuous motion in sensing area. 2. Sensor is faulty. | 1. Ensure no constant movement or heat sources are within the sensing range. 2. Disconnect power for 1 minute, then reconnect. If issue persists, sensor may be faulty. |
| Light turns off too quickly or too slowly. | Fixed 30-second delay time. | The delay time is fixed at 30 seconds and cannot be adjusted. Ensure expectations align with this specification. |
| Sensing distance is too short/long. | 1. Ambient temperature. 2. Installation height/angle. | 1. Sensing distance is affected by temperature (shorter in high temps, longer in low temps). 2. Adjust installation position or angle as per Section 5.1. |
9. User Tips
- Check Product Type: This sensor switch is available in different configurations, such as 'Terminal Type' and 'Long Wire Type'. Ensure you have the correct type for your specific installation needs.
- Voltage Compatibility: The sensor supports AC110-240V, making it suitable for various electrical systems.
- Load Limit: Remember the 40W maximum load. For higher power applications, consider using a relay in conjunction with the sensor (consult a qualified electrician).
- Optimal Placement: For best performance, avoid placing the sensor near heat sources (e.g., vents, direct sunlight) or in areas with constant air movement, as these can cause false triggers or reduced sensitivity.
10. Warranty and Support
For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
For additional resources, you may refer to the official product video:
Video: Product Overview and Features
A PDF user manual is also available for download from the product page for more detailed information.