1. Introduction
This manual provides instructions for the installation, operation, and maintenance of the Aideepen Mini Vacuum Manometer and Pressure Gauges. These compact and reliable instruments are designed for accurate measurement of vacuum or positive pressure in various applications.
Please read this manual thoroughly before using the device to ensure safe and efficient operation.
2. Safety Information
- Always ensure the gauge is compatible with the pressure range and medium being measured.
- Do not exceed the maximum rated pressure of the gauge.
- Ensure proper sealing during installation to prevent leaks.
- Avoid dropping or subjecting the gauge to severe impacts, as this can affect accuracy and durability.
- Keep the gauge clean and free from debris.
- Installation should be performed by qualified personnel if you are unsure.
3. Product Overview
The Aideepen Mini Vacuum/Pressure Gauges are compact, dial-type instruments featuring a dual scale for versatile readings. They are designed with a robust casing for protection in various environments.
3.1. Components
- Dial: Displays the measured pressure or vacuum.
- Pointer: Indicates the current reading on the dial.
- Case: Protective housing for internal components. Material may vary (steel, plastic, or iron).
- Window: Glass cover protecting the dial.
- Connection Thread: Male thread for connecting to the system.
3.2. Variants and Features
These gauges come in different variants, primarily distinguished by their measurement range and connection thread type:
1/4 OPS Vacuum Manometer
Front view of the 1/4 OPS Vacuum Manometer, showing the dial with inHg and bar scales.
- Measurement Range: 0 ~ -30 inHg or 0 ~ 1 bar (vacuum)
- Connection: 1/4" NPT
- Case: Steel case
1/4 BSP Pressure Gauge
Front view of the 1/4 BSP Pressure Gauge, showing the dial with PSI and Bar scales.
- Measurement Range: 0 ~ 180 PSI, 0 ~ 12 Bar (positive pressure)
- Connection: 1/4 BSP (G1/4")
- Case: May be plastic or iron (random delivery)
1/8 BSP Pressure Gauge
Front view of the 1/8 BSP Pressure Gauge, showing the dial with PSI and kg/cm² scales.
- Measurement Range: 0 ~ 180 PSI, 0 ~ 12 Bar (positive pressure)
- Connection: 1/8" NPT
- Case: May be plastic or iron (random delivery)
Diagram showing dimensions for the 1/8 BSP Pressure Gauge (approx. 42*40mm case, 9mm thread diameter).
4. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Aideepen |
| Model Number | Mini Vacuum Manometer / Vacuum Manometer |
| Display Type | DIGITAL (Dial) |
| Dial Diameter | 2" (1.9 Inches & Under) |
| Max Measuring Range | 49 PSI & Under |
| Accuracy | +/- 4/3/4% |
| Movement | Copper Alloy |
| Bourdon Tube | Copper Alloy |
| Window | Glass |
| Case Material | Steel (for 1/4 NPT vacuum), Plastic or Iron (for BSP pressure gauges) |
| Connection Method | Installation under copper alloy, 1/4" NPT (for vacuum) or 1/4 BSP / 1/8 NPT (for pressure) |
| Ambient Temperature | -4F to + 140F (-20C to + 60C) |
| Certification | CE |
| Origin | Mainland China |
Note: Specific pressure ranges and thread types vary by model. Refer to the "Product Overview" section for details on each variant.
5. Setup and Installation
- Identify Gauge Type: Confirm whether you have a vacuum manometer (e.g., 1/4" NPT, -30inHg to 0) or a pressure gauge (e.g., 1/4 BSP or 1/8 BSP, 0 to 180 PSI).
- Prepare Connection Point: Ensure the system's connection point matches the gauge's thread type (1/4" NPT, 1/4 BSP, or 1/8" NPT).
- Apply Sealant (Optional but Recommended): For a leak-free connection, apply a suitable thread sealant (e.g., PTFE tape) to the gauge's male thread.
- Install Gauge: Carefully screw the gauge into the system's port. Hand-tighten first, then use a wrench for a snug fit. Do not overtighten, as this can damage the threads or the gauge.
- Check for Leaks: After installation, pressurize the system (if safe to do so) and check for any leaks around the connection point using a leak detection spray or soapy water.
Examples of gauge installation in typical applications.
6. Operating Instructions
Once installed, the gauge operates automatically by sensing the pressure or vacuum in the connected system. The pointer will move across the dial to indicate the current reading.
- Reading the Dial: The gauges feature a dual scale. For vacuum manometers, typically inHg (inches of mercury) and bar (or kPa) are displayed. For pressure gauges, PSI (pounds per square inch) and Bar (or kg/cm²) are common. Read the value indicated by the pointer on the appropriate scale for your application.
- Vacuum Manometer (0 ~ -30 inHg): The pointer will move counter-clockwise from 0 as vacuum increases. -30 inHg represents a perfect vacuum.
- Pressure Gauge (0 ~ 180 PSI): The pointer will move clockwise from 0 as positive pressure increases.
- Ambient Temperature: The gauge is designed to operate within a normal ambient temperature range of -4F to +140F (-20C to +60C). Operating outside this range may affect accuracy.
7. Maintenance
- Cleaning: Wipe the gauge's exterior and glass window with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the casing or dial.
- Inspection: Periodically inspect the gauge for any signs of damage, such as cracks in the casing or window, or a bent pointer. Replace the gauge if significant damage is observed.
- Environmental Protection: While the steel case (for some models) offers protection, avoid exposing the gauge to extreme conditions, corrosive substances, or excessive vibrations to prolong its lifespan and maintain accuracy.
- Shell Material Note: For 1/4 BSP and 1/8 BSP pressure gauges, the shell material (plastic or iron) may vary. This does not affect the gauge's functionality.
8. Troubleshooting
8.1. Common Issues and Solutions
- Incorrect Reading:
- Ensure the gauge is correctly installed and there are no leaks in the system.
- Verify that the gauge type (vacuum or pressure) matches your application.
- If the gauge was subjected to impact, its calibration might be affected. Consider replacement.
- No Reading / Pointer Stuck:
- Check if there is actual pressure or vacuum in the system.
- Inspect the gauge for physical damage.
- Ensure the connection is not blocked.
- Gauge Received is Not the Expected Type (e.g., Pressure instead of Vacuum):
- Carefully review your order details and the product description to confirm the intended type.
- Contact the seller immediately if you believe an incorrect item was shipped.
9. User Tips
- Verify Gauge Type: Before installation, double-check the markings on the dial to ensure you have received the correct type of gauge (vacuum or pressure) for your specific needs. Some users have reported receiving a pressure gauge when expecting a vacuum manometer, or vice-versa.
- Test for Accuracy: If precise measurements are critical, it is advisable to test the gauge against a known accurate reference before relying on its readings.
- Handle with Care: Although designed to be robust, gentle handling during installation and use will help maintain its accuracy and extend its lifespan.
- Packaging: The product is typically well-packed to ensure safe delivery.
10. Warranty and Support
For any issues, questions, or support needs regarding your Aideepen Mini Vacuum/Pressure Manometer or Gauge, please contact the seller directly through the platform where the purchase was made. Provide your order details and a clear description of the issue for prompt assistance.
The manufacturer certifies that this product meets CE standards.
A user manual in PDF format is available for download: User manual (PDF)