PowMr HHJ-60A

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: HHJ-60A, POW-Keeper Series (20A, 30A, 40A)

1. Introduction

Thank you for choosing the PowMr MPPT Solar Charge Controller. This manual provides essential information for the safe and efficient operation of your controller. The PowMr MPPT Solar Charge Controller is designed to manage power flow from your solar panels to your battery bank, ensuring optimal charging and system protection. It features advanced Maximum Power Point Tracking (MPPT) technology for high efficiency, a DSP controller for fast signal processing, and compatibility with various battery types.

PowMr MPPT Solar Controller models 20A, 30A, 40A, and 60A

Figure 1: PowMr MPPT Solar Charge Controller models (POW-Keeper series and HHJ-60A)

Video 1: Official product introduction for the HHJ-60A model, highlighting key features and benefits.

2. Safety Instructions

  • Read all instructions carefully before installation and operation.
  • Ensure all wiring is correct and secure to prevent damage to the controller or other components.
  • Always connect the battery first, then the solar panel. If not operated in this order, the battery may be damaged.
  • Do not disassemble or attempt to repair the controller yourself. Contact support if issues arise.
  • Ensure proper ventilation around the controller to prevent overheating.
  • Keep the controller away from water, flammable materials, and corrosive substances.
  • Use appropriate circuit breakers and fuses as indicated in the wiring diagram.

3. Package Contents

Please check the package for the following items:

  • PowMr MPPT Solar Charge Controller (HHJ-60A or POW-Keeper model)
  • User Manual (this document)

Note: Wiring cables are not included and must be purchased separately.

PowMr MPPT Solar Charge Controller with wiring terminals and packaging

Figure 2: HHJ-60A model showing wiring terminals (PV+, PV-, BT+, BT-, OU+, OU-) and product packaging. Wiring is not included.

4. Setup

4.1 Wiring Precautions

It is crucial to follow the correct wiring sequence to prevent damage to the controller and other system components. The controller is a common positive controller, meaning the positive poles of the PV array, battery, and load can be grounded at the same time.

Solar energy system wiring diagram

Figure 3: Solar energy system wiring diagram. Shows connections for PV Array, Breaker, SCC (Solar Charge Controller), Fuse, Battery, and Load. PV+ and PV- connect to the solar array, BT+ and BT- to the battery, and OU+ and OU- to the load.

4.2 Connection Steps

  1. Step 1: Connect Batteries
    Connect the battery to the controller first. Ensure correct polarity (BT+ to battery positive, BT- to battery negative).
  2. Step 2: Connect the Load
    Connect the DC load to the controller (OU+ to load positive, OU- to load negative).
  3. Step 3: Connect the Solar Panels
    Connect the solar panels to the controller (PV+ to solar positive, PV- to solar negative).
  4. Step 4: Connect the Inverter to the Battery (Optional)
    If using an inverter, connect it directly to the battery terminals, not to the controller's load terminal.

4.3 Important Notices

  • If an inverter or other high starting current device is used, connect it directly to the battery, not to the controller's load terminal.
  • If a lithium battery is used, set the system voltage and the battery type before use. Refer to sections 5.4 and 5.5 for details.

5. Operating Instructions

5.1 LCD Screen Overview

The LCD screen displays various system parameters and status indicators.

LCD Screen Display

Figure 4: LCD screen layout showing icons for solar input, MPPT charging, battery, battery types (LiPo, LiFe), warning, load, system voltage (12V, 24V), and digital readouts for PV, BAT, LOAD in W°C, A, H.

5.2 Status Indicators

ItemIconStatus
PV array☀️ / 🌙Day / Night
PV array☀️ → MPPT → 🔋Charging
Battery🔋Uncharged / Battery capacity
Battery TypeLiPo / LiFeBattery type selected
Load💡 (on) / 💡 (off)Load on / Load off

5.3 Button Definitions

ButtonFunction
MENU (▲)Short Press: Switch down press. Hold for 3 seconds: Enter the next interface.
SET (▼)Short Press: Switch up. Press and hold for 3 seconds: Exit without saving.

5.4 Boot Screen

Upon power-on, the controller will display a sequence of screens:

  1. Starting Interface: Detects LCD.
  2. Battery Voltage Interface: Displays current battery voltage.
  3. Software Revision: Shows the firmware version.

Note: From the first interface, long press MENU to enter the secondary interface. It will automatically switch back to the first interface after 15 seconds of inactivity.

5.5 Main Loop Pages & Settings

After power-on, the LCD enters the main page. Short press MENU or SET to navigate through the main loop pages (e.g., Battery Temperature, Charging Current, Discharging Current, Accumulated Charging AH, Accumulated Discharging AH).

To enter the setting page, long press MENU for 3 seconds from the main page. Use short presses of MENU or SET to switch between settings. Long press MENU for 3 seconds to save changes, or long press SET for 3 seconds to return to the main page without saving.

Key Settings:

  • System Voltage: Auto-detection or manual setting (12V/24V). Long press MENU until 'auto' flashes, then use MENU/SET.
  • Battery Type: Select from USE 1 (custom), GEL, SLD (sealed), FLD (flooded), 4S LiFePO4, 5S LiFePO4, 3S Lithium-ion, 4S Lithium-ion, USE 2 (custom). For lithium batteries, set system voltage first.
  • Battery Parameters: Configure Resume Charge, Constant Voltage Charge, Equalization Charge, Absorption Charge, Float Charge, Low Voltage Protection, and Low Voltage Recovery voltages based on battery type. Refer to the technical data for default values.
  • Load Working Mode: Select from LD1 (Regular), LD2 (Light Control), LD3 (Light & Time Control), LD4 (Reverse Light Control).
  • PV Voltage Page: Long press SET for 3 seconds to switch between main page and PV voltage display.
  • Equalization/Absorption Charging Duration: Adjust the duration of these charging stages from their respective pages.

6. Maintenance

  • Regularly check all wiring connections for tightness and corrosion.
  • Keep the controller clean and free from dust and debris.
  • Ensure adequate ventilation around the controller.
  • Periodically inspect the battery terminals for corrosion and clean if necessary.

7. Troubleshooting

7.1 Protection Functions

The controller includes several protection features:

Protection functions list for PowMr MPPT Solar Charge Controller

Figure 5: Protection functions include PV short circuit, PV over current alarm, Battery overcharge, Battery over discharge, Battery reverse polarity, Load short circuit, Load overload, and Controller overheating.

ProtectionConditionStatus
Solar panel reversedSolar panel connected with reverse polarity when battery is not connected.Controller isn't broken.
Battery is reversedBattery connected with reverse polarity if PV is unconnected.Controller isn't broken.
Battery over-voltageBattery voltage reaches the over-voltage point.Stop charging and discharging.
Battery over-dischargeBattery voltage drops below the under-voltage point.Stop discharging.
Over-loadThe load current exceeds the rated current.Turn off the output.

7.2 Fault Management (Error Codes)

Error CodeCauseCorrection
PV array indicator offSolar panel disconnection.Check PV array connection.
No sign on LCDBattery voltage < 8V or PV voltage < battery voltage.Check battery voltage (min 8V) and ensure PV voltage is higher than battery voltage.
E 1Battery over discharge.Load stops, recovers when battery reaches 12.6V (LVR).
E 2Battery over voltage.Check high voltage disconnection setting, reconnect PV array.
E 3Over load.Reduce load or check load connection.
E 5Controller overheating.Controller will restart after cooling down.
E 6Input voltage of solar panel is too high.Check PV voltage, reduce number of solar panels in series.
E 7No operation.Controller will restart after setting system voltage.

Note: Fault codes consist of 'E' and two digits. The first digit is the error count, the second indicates the specific fault. E.g., 'E-12' means one error, specifically overvoltage in the battery.

8. Specifications

8.1 Electrical Specifications

Parameter20A Model30A Model40A Model
Rated Charge Current20A30A40A
Max. Open Voltage of PV Array<60V<75V<100V
System Rated Voltage12/24V Auto recognized
Battery Voltage Range8V~32V
Maximum Input Power260W(12V) / 520W(24V)390W(12V) / 780W(24V)520W(12V) / 1040W(24V)
Rated Discharge Current20A20A30A
Battery Type SupportUser default, Sealed, Flooded, GEL, LiFePO4, Li(NiCoMn)O2
Equalize Charging VoltageMaintenance-free lead-acid: 14.6V; GEL: 14.2V; Flooded: 14.6V (Duration: 2 hours)
Absorption Charging VoltageMaintenance-free lead-acid: 14.4V; GEL: No; Flooded: 14.8V (Duration: 2 hours)
Float Charging VoltageMaintenance-free lead-acid, GEL, Flooded: 13.8V
LVR (Low Voltage Reconnect)Maintenance-free lead-acid, GEL, Flooded: 12.6V
LVD (Low Voltage Disconnect)Maintenance-free lead-acid, GEL, Flooded: 10.8V

8.2 General Specifications

ParameterValue
Static Loss≤50mA
HVD (High Voltage Disconnect)Lead acid battery 16V
Light Control Voltage5V/10A
Temperature Compensation Coefficient-4mV/°C/2V (25°C)
Discharge Loop Voltage Drop≤0.2V
LCD Temperature-20°C ~ +70°C
Operating Temperature-20°C ~ +55°C
Storage Temperature-30°C ~ +80°C
Working Humidity≤90%, No condensation
Protection ClassIP30
Grounded TypePositive grounded
Aperture for InstallationΦ5mm

Note: All parameters are for 12V system at 25°C; values are doubled for 24V systems.

9. User Tips

  • This controller is a true MPPT device, offering high efficiency in solar charging.
  • It supports LiFePO4 batteries; ensure you select the correct battery type and set the system voltage accordingly before use.
  • For 48V systems, ensure your battery configuration (e.g., 13S LiFePO4 with 54.6V full charge) is within the controller's maximum open voltage of PV array and battery voltage range to prevent damage. For the 40A model, max PV input is <100V.
  • While multiple units can be used in a system, each controller typically manages its own battery bank or a segment of a larger bank. Direct joining of two units to regulate a single 120A load is not a standard configuration; consult a solar professional for such advanced setups.

10. Warranty and Support

PowMr offers a 1-year warranty on this product. For technical support, warranty claims, or further inquiries, please contact us using the information below:

  • Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China