PowMr HHJ-60A

Contents

PowMr MPPT 60A Solar Charge Controller

Model: HHJ-60A

User Manual

1. Important Safety Instructions

Please read and save these instructions.

1.1 General Safety Information

  • Read all instructions and cautions in this manual before beginning installation.
  • There are no serviceable parts inside this controller. Do NOT disassemble or attempt to repair it.
  • Do NOT allow water to enter the controller.
  • Ensure all connections going into and from the controller are tight.

1.2 Charge Controller Safety

  • WARNING: NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
  • Ensure input voltage does not exceed 160 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to verify this when connecting panels.

1.3 Battery Safety

  • Use only sealed lead-acid, flooded, gel, or lithium batteries designed for deep cycle applications.
  • Explosive battery gases may be present during charging. Ensure adequate ventilation.
  • When working with large lead-acid batteries, wear eye protection and have fresh water available in case of contact with battery acid.
  • Carefully read your battery manufacturer's manual before operation.
  • Do NOT let the positive (+) and negative (-) terminals of the battery touch each other.
  • Over-charging can damage battery plates. Review specific requirements for your battery.
  • Equalization is for non-sealed/vented/flooded/wet cell lead-acid batteries only. Do NOT equalize VRLA type AGM/Gel/Lithium cells unless permitted by the battery manufacturer.

WARNING: Connect battery terminals to the charge controller BEFORE connecting solar panels. NEVER connect solar panels until the battery is connected.

WARNING: Do NOT connect any inverters or battery chargers to the load terminal of the charge controller.

WARNING: There should be NO load on the batteries during the equalization charging stage.

2. Product Overview

The PowMr MPPT Solar Charge Controller (Model HHJ-60A) utilizes advanced Maximum Power Point Tracking (MPPT) technology, achieving a conversion efficiency of up to 97%. It is designed for robust performance and reliability in solar power systems.

Key Features:

  • MPPT 60A charging current.
  • High tracking efficiency (up to 99.9%).
  • Built-in high-performance DSP controller for fast digital signal processing.
  • Automatic voltage recognition for 12V/24V/36V/48V battery banks.
  • 5-stage charging process to optimize battery performance and extend life.
  • Comprehensive protections: overcharge, PV reverse polarity, output limited current, over-temperature, load short circuit, battery over-discharge.
  • Troubleshooting promotion function for easy fault diagnosis.
  • Compatible with various battery types: sealed lead-acid, vented, gel, and lithium batteries.
  • Easy to mount and install.

Video: Introduction to the PowMr HHJ-60A Solar Charge Controller, highlighting its features and benefits.

3. Setup and Installation

3.1 Dimensions

The controller measures 21.4 cm (8.43 in) in length, 11.5 cm (4.53 in) in width, and 5 cm (1.97 in) in height.

PowMr MPPT 60A Solar Charge Controller dimensions and internal components

Image: Physical dimensions of the controller and an illustration of its internal components.

3.2 Installation Notes

  • Use only the screws provided to avoid damaging the internal PCB.
  • Apply proper torque when tightening screws into the casing.
  • Ensure a space of approximately 5.91 inches (15 cm) around the controller for proper ventilation.

3.3 Wiring Sequence

Follow these steps carefully to ensure correct and safe installation:

  1. 1st Step: Connect the Batteries
    Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If your system is 12V, ensure battery voltage is above 12V for the controller to boot up.
  2. 2nd Step: Connect the Solar Panel
    Ensure PV modules are protected from incident light during connection. Verify that the solar panel's maximum permissible input current is not exceeded. Connect the PV modules' connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
  3. 3rd Step: Connect Loads
    Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid voltage on the wires, connect the wire to the load BEFORE connecting to the controller.
  4. 4th Step: Final Check
    Tighten all cables connected to the controller and remove any debris from around the controller.

3.4 Air Circuit Breaker Installation

It is strongly recommended to connect a fuse directly to the battery to protect against short circuits in the battery wiring. Protect solar PV modules from incident light during installation. Always use insulated tools and ensure wire diameter matches expected currents.

Air Circuit Breaker and Wires Requirement
ModelCopper WiresAir Circuit Breakers
MPPT-60A6mm²x2PCS100A

3.5 Wiring Diagram

Wiring diagram for PowMr MPPT 60A Solar Charge Controller

Image: Detailed wiring diagram showing connections for PV panels, controller, battery, and DC/AC loads. Includes support for parallel connection of controllers.

Installation Steps with Circuit Breakers:

  1. Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
  2. Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure PV polarity is correct, then connect wires between PV modules and controller.
  3. Turn on the air circuit breaker between controller and batteries.
  4. Turn on the air circuit breaker between controller and PV modules.
  5. The controller will enter self-test mode. The LCD will display parameters if all connections are correct. The RUN lamp (under the fan) will flash every second.

4. Operating Instructions

4.1 LCD Display

PowMr MPPT 60A Solar Charge Controller LCD interface and working modes

Image: Detailed view of the LCD interface, showing main and sub-interface displays, and descriptions of working modes.

The LCD provides real-time system status:

  • Main Interface: Displays PV voltage/output power, Battery voltage/charging current, Working mode/Temperature, and Fault codes.
  • Sub-interface: Allows access to settings like Load Timer (d00), Floating voltage (d01), Absorption voltage (d02), Under-voltage disconnection voltage (d03), Battery type (d04), and Calibration voltage (d05).

4.2 Working Modes

  • 3.0 Night Mode: No charging occurs.
  • 4.0 MPPT Mode: Maximum Power Point Tracking for efficient charging.
  • 7.0 Absorption Mode: Battery is charged to its full voltage at a decreasing current.
  • 8.0 Floating Mode: Battery is maintained at a constant voltage to prevent self-discharge.

4.3 Manual Settings

All manual settings should be performed when PV modules are disconnected from the controller.

  1. Step 1: D00 (Load Working Time)
    Press PRG, LCD shows D00. This sets load working time (default 24-hour). Press ENT until numbers flash, use UP/DOWN to set time, long-press ENT to confirm.
  2. Step 2: D01 (Floating Charging Voltage)
    Press UP, LCD shows 13.8 (default). Press ENT until numbers flash, use UP/DOWN to set voltage, long-press ENT to confirm.
  3. Step 3: D02 (Absorption Charging Voltage)
    Press UP, LCD shows 14.5 (default). Press ENT until numbers flash, use UP/DOWN to set voltage, long-press ENT to confirm.
  4. Step 4: D03 (Battery Discharge Protection)
    Press UP, LCD shows 10.0. This is the battery discharge protection value. Press ENT until numbers flash, use UP/DOWN to set voltage, long-press ENT to confirm.
  5. Step 5: D04 (Battery Type)
    Press UP, LCD shows 00.00 (default for acid batteries). For lithium batteries, press ENT until numbers flash, use UP/DOWN to choose 01, long-press ENT to confirm.
  6. Step 6: D05 (Battery Voltage Calibration)
    Press UP, LCD shows C+ (currently detected battery voltage). Adjust this value to match the actual battery voltage.

Press ESC to exit the setting menu. After setting, disconnect and reconnect the battery to confirm settings are saved, then connect PV modules.

4.4 Battery Charge Voltage Reference

Battery TypeAbsorption Voltage (Constant Voltage)Floating Voltage
System Voltage12V24V48V12V24V48V
Vented14.2V28.6V57.2V13.2V26.4V52.80V
Sealed14.4V28.8V57.6V13.8V27.6V55.2V
Gel14.4V28.8V57.6V13.8V27.6V55.2V
NiCd14.2V28.6V57.2V14.0V28.0V56.0V
Lithium or othersDefined by users

5. Maintenance

To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, regular maintenance is recommended:

  • Inspect Connections: Periodically check all wiring connections to ensure they are tight and free from corrosion. Loose connections can lead to power loss or overheating.
  • Clean the Controller: Keep the controller's exterior clean and free from dust and debris. Ensure the cooling fan and vents are unobstructed for proper heat dissipation.
  • Monitor System Performance: Regularly check the LCD display for any fault codes or unusual readings. Ensure the battery voltage and charging current are within expected ranges.
  • Battery Inspection: Follow your battery manufacturer's maintenance guidelines. Check battery terminals for corrosion and ensure proper ventilation if using flooded batteries.

6. Troubleshooting

The controller features a fault diagnosis system to help identify and resolve issues.

6.1 Fault Codes and Solutions

CodeDescriptionHow to Solve
18Input PV voltage is lowIncrease the PV voltage
60Over-temperature protectionFan will work and temperature reduction automatically
63Battery voltage is highBattery high voltage protection and wait for recovery
65Battery voltage is lowBattery over-discharge and wait for recovery
71Input PV voltage is highDecrease the PV voltage
73Over-charging currentDecrease the PV power

6.2 Built-in Protections

  • PV Over Current: Controller limits charging power to rated charge power.
  • PV Short Circuit: Controller stops charging. Remove short to resume.
  • PV Reverse Polarity: Full protection, no damage. Correct connection to resume.
  • Battery Over Voltage: Controller stops charging to protect battery from overcharging.
  • Battery Over Discharge: Controller stops discharging to protect battery from over-discharging.
  • Load Over Current: If load current exceeds 1.25 times max rating, controller disconnects load.
  • Load Short Circuit: Load short circuit protection activates automatically.
  • Over Temperature: Fan activates, and charging may be reduced or stopped to prevent overheating.

7. Specifications

7.1 Technical Data

ParameterSpecification (HHJ-60A)
Charging Mode3-stage: Constant Current (MPPT), Constant Voltage, Floating
Max. PV Input Power (12V System)720W
Max. PV Input Power (24V System)1440W
Max. PV Input Power (36V System)2100W
Max. PV Input Power (48V System)2800W
Input Specification DC (12V System)20V~80V
Input Specification DC (24V System)37V~105V
Input Specification DC (36V System)50V~160V
Input Specification DC (48V System)72V~160V
Battery Voltage Auto Recognition (12V)DC9V~DC15V
Battery Voltage Auto Recognition (24V)DC18V~DC29V
Battery Voltage Auto Recognition (36V)DC30V~DC39V
Battery Voltage Auto Recognition (48V)DC40V~DC60V
Overcharging Protection Voltage60V
Limited Current Protection61A
Max Efficiency≥98.1%
PV Utilization≥99%
Temperature Protection75°C / 167°F
Fan-on Temperature>45°C / 104°F
Fan-off Temperature<40°C / 95°F
Size (mm/in)214x115x50 mm / 8.43x4.53x1.97 in
Net Weight (Kg/lb)1.1 / 2.43
Gross Weight (Kg/lb)1.2 / 2.65
Electromagnetic CompatibilityAccord to EN61000, EN55022, EN55024
EnclosureIP21
Environmental Temperature-20°C ~ +55°C
Storage Temperature-40°C ~ +75°C

8. User Tips

  • Lithium Battery Compatibility: This controller works perfectly with LiFePO4 (lithium iron phosphate) batteries. Ensure you set the correct battery type (D04) in the manual settings.
  • Panel Configuration: For optimal performance, ensure your solar panel configuration (e.g., two 330W panels in series) matches the controller's input voltage range and your battery bank voltage (e.g., 24V). The controller is designed to handle such setups efficiently.
  • Weight: The net weight of the device is approximately 1.1 kg (2.43 lbs), and the gross weight is about 1.2 kg (2.65 lbs). This is useful for installation planning.
  • Quality: Users generally report good quality and reliable operation for this controller.

9. Warranty and Support

9.1 Warranty Regulations

  • 30-Day Replacement: Within 30 days from the purchase date, a faulty controller will be replaced free of charge under normal usage conditions (with authorization from technical personnel).
  • 2-Year Repair: Within 2 years from the purchase date, a faulty controller will be repaired free of charge.
  • Note: Disassembling the product privately will void the warranty.

9.2 Contact Information

For any questions or support, please contact:

  • Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

© 2024 PowMr. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.