KeKeQeen KSD301/KSD302

Contents

KSD301/KSD302 Thermal Control Switch User Manual

Model: KSD301 / KSD302 | Brand: KeKeQeen

Introduction

This manual provides instructions for the safe and effective use of your KeKeQeen KSD301 and KSD302 series thermal control switches. These switches are designed to regulate temperature by opening or closing an electrical circuit at a predetermined temperature point. Please read this manual thoroughly before installation and operation.

Setup and Installation

The KSD301 and KSD302 thermal control switches are designed for easy integration into various electrical systems. Ensure the power supply is disconnected before installation to prevent electrical shock.

Mounting

The switches typically feature mounting holes for secure attachment. Refer to the technical drawings for precise dimensions and mounting hole locations.

Technical drawing with dimensions for KSD301/KSD302 thermal switches
Figure 1: Technical drawing showing dimensions for KSD301/KSD302 switches. Dimensions include overall length (34mm), width (32mm), and terminal spacing.
Detailed technical drawing of KSD301/KSD302 switch with various foot configurations
Figure 2: Detailed technical drawing illustrating different foot configurations and their respective dimensions for KSD301/KSD302 models.

Electrical Connection

Connect the switch terminals into your circuit. Ensure connections are secure and appropriate for the rated voltage and current. The switches are available with either straight or 90-degree angle feet for various installation needs.

Two KSD302 thermal switches, one 250V 16A 250°C and another 250V 16A 200°C
Figure 3: KSD302 thermal control switches with different temperature ratings.
KSD302 thermal switch with 90-degree angle feet
Figure 4: KSD302 thermal switch featuring 90-degree angle feet for specific mounting orientations.
KSD302 thermal switch with straight feet
Figure 5: KSD302 thermal switch with straight feet for standard connections.

Operating Principles

The KSD301/KSD302 series are bimetallic disc thermostats that operate on a "sudden jump" principle, providing rapid switching action once the set temperature is reached.

Switch Types

  • Normally Closed (NC) Type:

    At normal temperatures, the contacts are closed, allowing current to flow (working state). When the ambient temperature rises and exceeds the nominal operating temperature, the bimetallic disc snaps open, disconnecting the contacts and interrupting the circuit. As the temperature drops below the recovery temperature, the contacts close again, restoring the circuit. This type is commonly used in applications like electric kettles where power needs to be cut off when a certain temperature is reached.

  • Normally Open (NO) Type:

    At normal temperatures, the contacts are open, preventing current flow (not working state). When the ambient temperature rises and exceeds the nominal operating temperature, the bimetallic disc snaps closed, connecting the contacts and completing the circuit. As the temperature drops below the recovery temperature, the contacts open again, interrupting the circuit. This type is used when a circuit needs to be activated upon reaching a certain temperature.

Circuit diagrams for Normally Closed and Normally Open switches
Figure 6: Circuit diagrams illustrating the operation of Normally Closed (left) and Normally Open (right) thermal switches.

Maintenance

These thermal control switches are generally maintenance-free. However, to ensure optimal performance and longevity:

  • Keep the switch clean and free from dust, debris, and moisture.
  • Periodically inspect the electrical connections for tightness and signs of corrosion.
  • Avoid exposing the switch to excessive mechanical stress or vibration.
  • Do not attempt to disassemble or modify the switch, as this may affect its calibration and safety features.

Troubleshooting

If you encounter issues with your thermal control switch, consider the following:

  • Switch not activating/deactivating at correct temperature:
    • Verify that the correct temperature rating for your application was selected.
    • Ensure the switch is properly installed and making good thermal contact with the component or area it is monitoring.
    • Check for external heat sources or drafts that might be affecting the switch's temperature sensing.
  • No power to the circuit:
    • Check all electrical connections for looseness or damage.
    • Ensure the power supply is active.
    • If using a Normally Closed switch, confirm the ambient temperature is below the recovery temperature.
  • Incorrect product received:
    • Double-check the model number and temperature rating against your order.

For persistent issues, consult a qualified electrician or contact customer support.

Specifications

Attribute Value
Product Name Sudden Jump Temperature Control Switch
Model Numbers KSD301, KSD302
Switch Type Temperature Switch (Normally Closed / Normally Open variants)
Working Voltage AC 250V
Rated Current 10A / 16A
Contact Life ≥ 50,000 cycles
Contact Resistance ≤ 50 MΩ
Insulation Resistance ≥ 100 MΩ
Electrical Strength 2500V/S (No breakdown, no flashover)
Operating Temperature Nominal temperature ±5°C (Available from 145°C to 300°C)
Recovery Temperature Nominal temperature -25°C ±8°C
Material (16A) Iron Ceramics
Material (10A) Iron Bakelite
Certification CQC, RoHS
EU LVD Voltage High voltage: Above 50Vac or 75Vdc
High-concerned chemical None

User Tips

  • Verify your order: Before installation, always confirm that the received switch model and temperature rating match your requirements. This helps avoid installation errors and ensures proper functionality.
  • Consider the application: The KSD301/KSD302 switches are generally reliable for their intended use. Ensure the chosen temperature setting is appropriate for your specific application to achieve desired results.

Warranty and Support

For specific warranty details, please refer to the terms and conditions provided by your retailer or contact KeKeQeen customer support directly. Keep your purchase receipt for any warranty claims.