DALY Daly Smart bms RS485 CAN

Contents

Daly Smart BMS User Manual

Model: Daly Smart bms RS485 CAN

For LiFePo4 and Li-Ion Battery Packs (3S-24S, 40A-500A)

1. Introduction

The Daly Smart BMS is designed for lithium battery management systems, meeting the demands for high performance, reliability, and cost-effectiveness in the lithium battery industry. This product facilitates real-time acquisition, processing, and storage of battery pack information to ensure the safety, availability, and stability of the battery pack during use.

2. Product Overview and Features

  • Professional High-Current Design: Utilizes professional high-current trace design and technology to withstand ultra-large current impacts.
  • Durable Construction: Features an injection molding sealing process to enhance moisture resistance, prevent component oxidation, and prolong the product's service life.
  • Robust Protection: Provides dustproof, shockproof, and anti-squeezing protection.
  • Comprehensive Safety Functions: Includes complete over-charge, over-discharge, over-current, short-circuit, and equalization functions.
  • Integrated Management: Designed with integrated acquisition, management, and communication capabilities.
  • Configurable Parameters: Communication function allows setting parameters such as over-charge, over-discharge, over-current, charge-discharge over-current, equalization, over-temperature, under-temperature, sleep, and capacity via a host computer.

Video: Overview of Daly S-Series Smart BMS features, including high current resistance, parallel connection support, intelligent functions, and extended lifespan.

3. Product Selection

When selecting your BMS, consider the following options:

  • Battery Type: LiFePo4 (Lithium Iron Phosphate)
  • Battery String Count: Available for 12S, 15S, 16S, 20S, 24S. Note: This BMS does not support concurrent strings; the factory determines the number of strings.
  • Rated Discharge Current: Available in 150A and 200A options.
  • Communication Mode: Options include UART or UART+RS485+CAN.
  • Optional External Accessories: Available accessories include Bluetooth, WiFi, GPS, Heating Module, Parallel Module, Buzzer, Key, and Display/Light Board.

4. Technical Parameters

4.1. System Framework Diagram

System Framework Diagram of Daly Smart BMS

Figure: Overview of the internal components and connections within the Daly Smart BMS.

4.2. Charging & Discharging With Passive Equalization

Parameter Default Value Unit Remarks
Rated Discharge Current 150-200 A
Charge Voltage 3.65*n V n is Battery Strings
Rated Charge Current 150-200 A
Balanced Start Voltage 3.4 V Configurable
Balanced Opening Voltage Difference ≥20 mV Configurable
Balance Current 100±30 mA

Passive equalization starts when both of the following conditions are met: the set balanced start voltage is reached, AND the highest voltage reaches the set balanced start voltage difference.

Passive Equalization Module Diagram

Figure: Passive equalization module with 100mA balancing current to extend lithium battery life.

4.3. Over-Charging Protection

The BMS includes multi-level over-charging protection for both single cells and the total battery pack voltage. These parameters are configurable.

Protection Type Default Value Unit Remarks
Single Cell Over-Charging
Alarm Voltage (First Level) 3.65±0.05 V
Alarm Release Voltage (First Level) 3.55±0.05 V
Protection Voltage (Second Level) 3.75±0.05 V Configurable
Protection Recover Voltage (Second Level) 3.65±0.05 V Configurable
Protection Voltage (Third Level) 3.80±0.05 V
Protection Recover Voltage (Third Level) 3.70±0.05 V
Total Voltage Over-Charging
Alarm Voltage (First Level) (3.6±0.05)*n V n is Battery Strings
Alarm Recover Voltage (First Level) (3.5±0.05)*n V
Protection Voltage (Second Level) (3.7±0.05)*n V Configurable
Protection Recover Voltage (Second Level) (3.6±0.05)*n V Configurable
Protection Voltage (Third Level) (3.75±0.05)*n V
Protection Recover Voltage (Third Level) (3.65±0.05)*n V
Delay
Single Cell Over-Charging Voltage Delay (Second Level) 1±0.8 S
Single Cell Over-Charging Voltage Delay (Third Level) 1±0.8 S
Total Voltage Over-Charging Delay (Second Level) 1±0.8 S
Total Voltage Over-Charging Delay (Third Level) 1±0.8 S

4.4. Over-Discharging Protection

The BMS includes multi-level over-discharging protection for both single cells and the total battery pack voltage. These parameters are configurable.

Protection Type Default Value Unit Remarks
Single Cell Over-Discharging
Alarm Voltage (First Level) 2.3±0.05 V
Alarm Release Voltage (First Level) 2.4±0.05 V Configurable
Protection Voltage (Second Level) 2.2±0.05 V
Total Voltage Over-Discharging
Alarm Voltage (First Level) (2.35±0.05)*n V n is Battery Strings
Alarm Recover Voltage (First Level) (2.45±0.05)*n V
Protection Voltage (Second Level) (2.25±0.05)*n V Configurable
Protection Recover Voltage (Second Level) (2.35±0.05)*n V Configurable
Protection Voltage (Third Level) (2.15±0.05)*n V
Protection Recover Voltage (Third Level) (2.25±0.05)*n V
Delay
Single Cell Over-Discharging Voltage Delay (Second Level) 5±0.8 S
Single Cell Over-Discharging Voltage Delay (Third Level) 3±0.8 S
Total Voltage Over-Discharging Delay (Second Level) 5±0.8 S
Total Voltage Over-Discharging Delay (Third Level) 3±0.8 S

4.5. Over-Current Protection

The BMS provides multi-level over-current protection during charging and discharging. These parameters are configurable.

Continuous Current 1st Level Over-Current (Charging/Discharging) 2nd Level Over-Current (Charging/Discharging) 3rd Level Over-Current (Charging/Discharging)
150A 180±3%A (1.2x current) @ Delay 1±0.8s 225±3%A (1.5x current) @ Delay 55±0.8s 450±3%A (3x current) @ Delay 1±0.8s
200A 240±3%A (1.2x current) @ Delay 1±0.8s 300±3%A (1.5x current) @ Delay 55±0.8s 600±3%A (3x current) @ Delay 1±0.8s

4.6. Short Circuit Protection

The BMS includes short circuit protection. The factory default condition is an external load short circuit, with a protection delay of 10-500 microseconds (us).

Important Note: Short-circuit current less than the minimum value or higher than the maximum value may cause short-circuit protection failure. Short-circuit protection tests are not guaranteed and not recommended.

4.7. Temperature Protection (External & MOS)

The BMS monitors both external and MOS temperatures for alarms and protection. Parameters are configurable.

Protection Type Default Value Unit
Charging High Temperature
Alarm Temperature (First Level)60±3°C
Alarm Release Temperature (First Level)55±3°C
Protection Temperature (Second Level)65±3°C
Protection Recover Temperature (Second Level)60±3°C
Protection Temperature (Third Level)75±3°C
Protection Recover Temperature (Third Level)65±3°C
Discharging High Temperature
Alarm Temperature (First Level)65±3°C
Alarm Recover Temperature (First Level)60±3°C
Protection Temperature (Second Level)70±3°C
Protection Recover Temperature (Second Level)65±3°C
Protection Temperature (Third Level)75±3°C
Protection Recover Temperature (Third Level)70±3°C
Charging Low Temperature
Alarm Temperature (First Level)-30±3°C
Alarm Recover Temperature (First Level)-25±3°C
Protection Temperature (Second Level)-35±3°C
Protection Recover Temperature (Second Level)-30±3°C
Discharging Low Temperature
Alarm Temperature (First Level)-30±3°C
Alarm Recover Temperature (First Level)-25±3°C
Protection Temperature (Second Level)-35±3°C
Protection Recover Temperature (Second Level)-30±3°C
MOS High Temperature
Alarm Temperature (First Level)90±3°C
Alarm Recover Temperature (First Level)85±3°C
Protection Temperature (Second Level)100±3°C
Protection Recover Temperature (Second Level)95±3°C
Protection Temperature (Third Level)110±3°C
Protection Recover Temperature (Third Level)105±3°C

4.8. Voltage Difference Alarm

The BMS monitors voltage differences across cells to prevent issues. Parameters are configurable.

Alarm Level Default Value Unit Remarks
Level 1 Alarm 0.5 V Configurable
Level 1 Alarm Recovery 0.3 V Configurable
Level 2 Protection 0.8 V Configurable
Level 2 Protection Recovery 0.5 V Configurable
Level 3 Protection 1 V Configurable
Level 3 Protection Recovery 0.8 V Configurable
Delay for Alarm & Protection 1±0.8 S

4.9. Temperature Difference Alarm

The BMS monitors temperature differences for alarms. Parameters are configurable.

Alarm Level Default Value Unit
First Level Alarm 10±2 °C
First Level Alarm Recovery 5±2 °C
Second Level Alarm 15±2 °C
Second Level Alarm Recovery 10±2 °C
Third Level Alarm 20±2 °C
Third Level Alarm Recovery 15±2 °C
Delay 1±0.8 S

4.10. Thermal Runaway

The BMS is equipped with thermal runaway detection. When triggered, it performs protective actions.

Trigger Conditions:

  1. Single unit voltage drops continuously (≥0.1V/second for 3 seconds) AND instantaneous temperature rise is too large (≥5°C/2 seconds).
  2. Battery temperature rises (above max operating temp 70°C) AND instantaneous temperature rise is too large (≥10°C/2 seconds).

Action: The BMS will turn off charging/discharging MOS tubes, activate the buzzer (DO1 high level), and the host computer will report a thermal runaway fault.

5. Communication Description

5.1. UART Communication

The default communication protocol is UART. It allows direct communication with Bluetooth modules, display screens, and host computers. Custom communication protocols can also be supported.

5.2. RS485 Communication (Optional)

The default RS485 communication protocol uses a special communication box to connect to a designated host computer. The default baud rate is 9600bps. This allows viewing battery information (voltage, current, temperature, state, SOC, production info) and performing parameter settings and control operations after login. Program upgrade functions are also supported.

5.3. CAN Communication (Optional)

The default CAN protocol has a communication rate of 250KB/S.

5.4. Buzzer Logic

The buzzer function can be configured via the PC Master and connects to the DO1 port. The default logic is that the buzzer will ring for 1 second and stop for 1 second when the charging and discharging temperature reaches 60°C, continuing until the temperature is below 60°C. Other custom logics can be implemented.

5.5. Indicator Light Logic

The BMS features a green LED indicator light. Its status indicates:

  • Light Off: Shutdown, power outage, or hibernation.
  • Flashing (0.5s on, 2.5s off, 3s cycle): During discharge operation.
  • Flashing (0.5s on, 0.5s off, 1s cycle): During charge state.
  • Flashing (0.5s on, 9.5s off, 10s cycle): No charging or discharging operation.

5.6. Keyswitch Logic

The keyswitch can control the MOS and hibernation. By default, this function is disabled. Two optional logics can be configured via the host computer or factory settings:

  1. Key control discharge MOS tube.
  2. Key control discharge MOS tube with hibernation.

The control logic is positive, meaning control is active when the switch is closed. Custom logics, such as 5V/12V/24V external power supply wake-up or simultaneous control of charging and discharging MOS, can be implemented.

6. PC Master Description

The DALY BMS Tool PC software provides a data monitoring interface. After logging in with a password and connecting to the BMS, users can access data monitoring, parameter reading and writing, production manufacturing, and other interfaces. The mobile app allows setting secondary and tertiary protection parameters.

Key functions include:

  • Analyzing and displaying data (voltage, temperature, configuration values) from each module.
  • Configuring information to each module via the host computer.
  • Calibrating production parameters and BMS upgrades.

7. Dimensional Drawing Reference

7.1. 150A Model (without fan)

Dimensional drawing of 150A BMS without fan

Figure: Schematic diagram of 150A BMS (without fan). Mainframe dimensions: 164.7mm (L) x 66mm (W) x 21.5mm (H).

7.2. 200A Model (with fan)

Dimensional drawing of 200A BMS with fan

Figure: Schematic diagram of 200A BMS (with fan). Mainframe dimensions: 164.7mm (L) x 66mm (W) x 21.5mm (H). Note: Fan airflow is towards the inside of the BMS. The fan surface must not be glued, as this will affect heat dissipation.

Dimensions for 40A BMS

Figure: Dimensions for a 40A BMS model (65*123*14mm).

8. Interface Definition

8.1. Interface Pin Instructions

Interface Name Pin No. Label Definition
B- interface / B- Battery negative, connect to battery negative
P- interface / P- Charge and discharge negative terminal of the protection board, connected to the negative terminal of charge and discharge
Sampling interface 1 B0 Connect to the negative terminal of the first battery
Sampling interface 2 B1+ Connect to the positive terminal of the first battery
NTC-A interface (GH1.25 4Pin) 1 NTC-1 1#Temperature line
NTC-A interface (GH1.25 4Pin) 2 GND Ground
NTC-A interface (GH1.25 4Pin) 3 GND Ground
NTC-A interface (GH1.25 4Pin) 4 NTC-2 2#Temperature line
UART1 interface (GH1.25 6Pin) 1 GND Ground
UART1 interface (GH1.25 6Pin) 2 3.3V Power supply is 3.3V
UART1 interface (GH1.25 6Pin) 3 12V Power supply is 8-12V
UART1 interface (GH1.25 6Pin) 4 S1 Activate button
UART1 interface (GH1.25 6Pin) 5 TX Communication sending end
UART1 interface (GH1.25 6Pin) 6 RX Communication receiving end
RS485/CAN interface (GH1.25 5Pin) 1 485 B 485 communication receiver
RS485/CAN interface (GH1.25 5Pin) 2 485_A 485 communication sender
RS485/CAN interface (GH1.25 5Pin) 3 ISO_GND Isolation ground GND
RS485/CAN interface (GH1.25 5Pin) 4 CAN H CAN communication high
RS485/CAN interface (GH1.25 5Pin) 5 CAN L CAN communication low
NTC-B interface (GH1.25 4Pin) 1 NTC-3 3#Temperature line
NTC-B interface (GH1.25 4Pin) 2 GND Ground
NTC-B interface (GH1.25 4Pin) 3 GND Ground
NTC-B interface (GH1.25 4Pin) 4 NTC-4 4#Temperature line
KEY interface (GH1.25 4Pin) 1 KEY+ Key switch positive
KEY interface (GH1.25 4Pin) 4 KEY- Key switch negative
DIO parallel interface (GH1.25 5Pin) 1 DO1 12V ≤500mA DO
DIO parallel interface (GH1.25 5Pin) 2 GND Ground
DIO parallel interface (GH1.25 5Pin) 3 DI Reserved
DIO parallel interface (GH1.25 5Pin) 4 GND Ground
DIO parallel interface (GH1.25 5Pin) 5 DO2 3.3V ≤200mA DO

8.2. Description of Main Wires

Line Name Default Specification Optional Specifications
CAN/485 line None 26AWG L=300mm GH1.25
B- P- line M6 Nut Terminal, No line. M6_SC16-5_3512 L=100mm
NTC line 28AWG L=250mm GH1.25 L=500mm, L=700mm, L=900mm
Wiring diagram for battery pack connection

Figure: General wiring diagram for connecting the BMS to a battery pack, electric machine, load, and recharger.

9. Wiring Instructions and APP Downloads

For detailed wiring instructions and to download the APP, scan the QR code below or visit the official website: https://www.dalyelec.com/service.html

QR code for Daly BMS user manual and app download

Scan this QR code to access the user manual and download the APP.

Daly BMS with battery packs and mobile app interface

Figure: Daly BMS connected to battery packs, showing the mobile app interface for monitoring.

10. Precautions

  • Voltage Platform Compatibility: Do not mix BMS of different voltage platforms (e.g., NMC BMS cannot be used on LFP batteries).
  • Cable Usage: Always use the company's matching cables. Cables from different manufacturers are not universal.
  • Anti-Static Measures: Take appropriate anti-static measures when testing, installing, touching, and using the BMS.
  • Heat Dissipation: Do not allow the heat dissipation surface of the BMS to directly contact battery cells, as this can transfer heat to the cells and affect battery safety.
  • Modification: Do not disassemble or change BMS components yourself.
  • Assembly: Avoid contact between the heat sink and the battery core and nickel strip during assembly operations.
  • Abnormal Operation: If the BMS behaves abnormally, stop using it immediately and resume only after the problem is resolved.
  • Connector Handling: When plugging and unplugging connector cables, press the buckle to avoid damaging the wires.
  • Series Connection: For series connection, customization is required.
  • 12V Output for 4/5S LiFePo4: For 4S or 5S LiFePo4 batteries, the 12V voltage from the UART and DO ports of the BMS may not regulate voltage output. The actual voltage value will be slightly lower than the total battery voltage. This may lead to insufficient power supply for accessories like WiFi or 4G modules, rendering them unusable.

11. User Tips

  • The BMS is generally easy to install, but be aware that there are many settings to configure.
  • The balance cable may be short; if extending, ensure proper soldering with sufficient space.
  • Refer to the detailed wiring video explanations for guidance.

12. Specifications

12.1. General Product Information

  • Model Number: Daly Smart bms RS485 CAN
  • Accessory Type: Battery Accessories, BMS
  • Applications: Li-ion / LiFePo4 battery, AGV/Scooter/EV etc.
  • Battery Series: 3-24S
  • Over Charge Protection: Yes
  • Over Discharge Voltage Protection: Yes
  • Short Circuit Protection: Yes
  • Balance Function: 100mA
  • Default Features: Bluetooth, RS485/CAN/Dual Uart port, 1A Parallel Function
  • Charger included: No
  • Battery Included: No
  • Hign-concerned Chemical: None
  • Certification: CE, FCC, RoHS, pse
  • Origin: Mainland China

12.2. Reliability Parameters

Parameter Condition/Value
Current Detection Accuracy ≤3%FSR (normal temperature)
Voltage Detection Accuracy ≤15mV (normal temperature)
Temperature Detection Accuracy ≤2°C (normal temperature)
Information Storage Up to 400 messages (512Kb EEPROM) including protection times, current total voltage, current, temperature, SOC, etc.
Operating Temperature -30°C ~ 70°C
Working Environment Relative Humidity 5% ~ 90%RH
Storage Temperature -40°C ~ 85°C
Storage Environment Relative Humidity 5% ~ 75%RH
Battery Capacity Low Alarm <10%
Main Circuit Internal Resistance <20mΩ
Working Self-Consuming Electrical Current <50mA (normal voltage, no peripheral accessories)
Sleep Mode Self-Consuming Electrical Current <800uA (normal voltage, no peripheral accessories)
Sleep Time 3600s (configurable to never sleep)
Maximum Power for External Accessories 6W
Fan On Temperature 47±3°C

12.3. Auxiliary Module Parameters

Module Name Current Standard Configuration Remarks
Parallel module 1A integrated Yes Built-in constant power 3W, max current 1A. For parallel connection without damage.
Parallel module 5A external No If high current limiting is needed, select external module.
Parallel module 15A external No

13. Warranty and Support

All lithium battery BMS produced by our company come with a one-year warranty. If the damage is caused by human factors, paid maintenance will be provided.

Our products undergo strict factory inspection and testing. However, due to varying customer environments (high temperature, ultra-low temperature, direct sunlight, etc.), it is possible for the protection board to fail. Therefore, when selecting and using a BMS, it is recommended to operate it in a friendly environment and choose a BMS with a certain redundancy capability.

For further assistance, you can refer to the official user manual available as a PDF: User manual (PDF).

14. Frequently Asked Questions (FAQ)

Q: Can the Daly BMS communicate with Victron Energy via CAN?
A: Yes, the BMS can communicate via CAN with all BMS that include a UART Port.
Q: What is included in the scope of delivery?
A: The packing list typically includes the Smart BMS, Manual, B-P- Output line, Bluetooth module (gift), Cables, NTC, and CAN/485 5pin. (Note: The packing list takes 60A BMS as an example. 300-500A (S series) products include free B-P- output line x2).
Packing list for Daly BMS

Figure: Typical packing list for Daly BMS.

Q: Does the 100A version have M6 or M8 connectors?
A: The specific connector size (M6 or M8) for the 100A version is not explicitly stated in the general specifications. Please refer to the detailed product specifications or contact support for exact details.
Q: Does this BMS have WiFi or only Bluetooth?
A: The BMS supports Bluetooth communication. WiFi and GPS modules are listed as optional external accessories, meaning they are not built-in by default.
Q: What is the password for connection?
A: The default password for connection is typically '123456'. If this is not working, please ensure you are using the correct application or software version.
Q: Does this new smart BMS require new accessories?
A: It is recommended to use matching cables and accessories provided by Daly to ensure compatibility and proper function.
Q: Is an active balancer needed for the 200A 16S model, or does the BMS have this function?
A: The Daly Smart BMS includes a passive equalization function with a balance current of 100±30mA. An active balancer is typically a separate component for more aggressive balancing.
Q: Can the discharge and charge voltage be adjusted from the screen?
A: Yes, parameters such as over-charge and over-discharge voltages can be set through the host computer software or mobile application.
Q: Can I charge and discharge the battery simultaneously?
A: Yes, the BMS is designed with a common port for both charging and discharging, allowing simultaneous operation.
Q: What is the 'parallel module' for?
A: The parallel module (integrated 1A or external 5A/15A) is used for parallel connection of battery packs, allowing safe expansion and higher current capabilities.

© 2024 Daly BMS. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.