Jiayin JYPS-4 Electromagnetic Pump User Manual

Model: JYPS-4

1. Product Overview

This electromagnetic pump is a miniature fluid delivery device driven by electromagnetic reciprocation. It relies on alternating magnetic force to drive the internal plunger for reciprocating motion, so as to realize the continuous delivery of liquid medium. It features small volume, low noise, stable flow rate, no rotating shaft structure and simple control. It is widely applied in small water supply equipment, steam coffee machines, steam irons, medical infusion auxiliary equipment, small cleaning machines, humidifiers, chemical micro-liquid dosing systems, and household steam appliances.

2. Safety Warnings

  1. Strictly match the rated voltage marked on the nameplate before power-on; overvoltage will burn the electromagnetic coil rapidly, while undervoltage causes unstable liquid output and insufficient pressure.
  2. Only deliver clean, low-viscosity neutral liquid; solid particles, corrosive liquid, or high-concentration oil will jam the plunger assembly and damage the internal sealing structure.
  3. Install the pump following the marked inlet and outlet direction; reverse connection leads to no liquid output and abnormal vibration.
  4. Cut off the power supply completely before disassembly, maintenance, or pipeline replacement to prevent liquid splashing and electric shock hazards.
  5. Keep the coil part away from liquid splashing, high humidity, and corrosive gas to avoid coil short-circuit and insulation aging failure.
  6. Do not run the pump without liquid medium for a long time; dry operation will wear the internal plunger and sealing ring sharply, resulting in permanent leakage.

3. Installation Instructions

3.1 Pre-installation Inspection

  1. Check the pump appearance to confirm no shell cracks, joint damage, or coil deformation; check that the internal flow channel is free of blockages.
  2. Clean the pipeline thoroughly before installation to remove impurities such as rust and debris, preventing foreign matter from jamming the plunger.
  3. Confirm the power supply type (AC/DC) and voltage are consistent with the rated parameters of the electromagnetic pump.

3.2 Pipeline Mounting Steps

  1. Distinguish the inlet and outlet ports strictly according to the marks on the pump body; the liquid can only flow from the inlet to the outlet.
  2. Connect the soft pipeline tightly to the inlet and outlet joints, and fix the pipeline with pipe clamps to prevent liquid leakage caused by loose falling off.
  3. The pump can be installed horizontally or vertically; reserve proper space around the coil for heat dissipation to avoid heat accumulation.
  4. It is recommended to install a small filter at the inlet end to intercept solid impurities and prolong the service life of internal moving parts.

3.3 Electrical Wiring

  1. Open the terminal box of the coil, fix the power cord with a wire sealing head to prevent water and dust from entering the interior.
  2. Connect the power cord and ground wire (if equipped) in accordance with the wiring diagram inside the terminal box; reliable grounding avoids electric leakage risks in wet working environments.
  3. Tighten all terminal screws firmly; poor contact will generate high temperature and sparks to burn the coil.
  4. Cover the terminal box completely after wiring to achieve dust-proof and waterproof effects.

4. Operation Guide

  1. Complete pipeline connection and wiring first, then inject liquid into the flow channel for priming, and never run the pump dry directly.
  2. Carry out short-time trial operation after power-on, check whether the liquid flows out stably, and observe for abnormal vibration, noise, or liquid leakage at the joints.
  3. Keep the pipeline pressure within the rated working range during formal operation; excessive back pressure will cause the pump to stop liquid output.
  4. Avoid frequent continuous start-stop operation, which will aggravate the impact on the coil and accelerate the aging of the sealing ring.
  5. For high-temperature liquid delivery scenarios, preheat the pipeline slowly to prevent thermal deformation of the sealing parts.

5. Daily Maintenance & Storage

Regular Routine Maintenance

  • Weekly: Wipe the dust and liquid stains on the pump shell and coil surface, check for liquid leakage at pipeline joints.
  • Monthly: Clean the inlet filter to remove accumulated impurities, test the stability of liquid flow and output pressure.
  • Quarterly: Check the tightness of wiring terminals and the aging degree of internal sealing rings; replace the sealing parts in time if leakage occurs.

Long-term Storage

  1. Drain all residual liquid inside the pump flow channel completely, and dry the internal cavity thoroughly to avoid scaling and rusting.
  2. Store the pump in a dry and ventilated environment with relative humidity lower than 65%, away from corrosive gas and heavy extrusion.
  3. Seal the inlet and outlet ports with protective plugs to prevent dust and foreign matter from entering the internal plunger structure.

6. Common Faults & Troubleshooting

Fault PhenomenonPossible CausesSolutions
No liquid output after power-on
  • Wrong inlet/outlet reverse connection
  • Dry operation without liquid priming
  • Pipeline blocked by impurities
  • Reconnect the pipeline following the inlet/outlet marks
  • Fill liquid into the pump cavity for priming
  • Disassemble and clean the pipeline and flow channel
Unstable flow and pressure fluctuation
  • Air mixed in the pipeline
  • Loose pipeline joints leading to air intake
  • Partial blockage of the inlet filter
  • Exhaust the air inside the pipeline completely
  • Fasten the loose pipeline joints
  • Remove and clean the inlet filter
Coil overheating or burnout
  • Long-term overvoltage power supply
  • Frequent high-frequency start-stop
  • Poor heat dissipation caused by closed installation
  • Replace with a power supply matching the rated voltage
  • Reduce the start-stop frequency reasonably
  • Reserve enough heat dissipation space for the coil
Liquid leakage at joints or pump body
  • Loose pipeline connection
  • Aging and cracking of internal sealing ring
  • Excessive pressure exceeding the rated range
  • Fasten the pipeline joints with pipe clamps
  • Disassemble and replace the damaged sealing ring
  • Adjust the back pressure to the rated working range

7. Specifications

Below are the technical specifications for the Jiayin JYPS-4 Electromagnetic Pump:

Jiayin JYPS-4 Electromagnetic Pump with label showing specifications

Image: Front view of the Jiayin JYPS-4 pump, displaying its label with model, voltage, power, frequency, and temperature ratings.

Parameter ItemSpecification Content
Brand / ModelJiayin / JYPS-4
TheoryElectromagnetic Pump
Power SourceElectric
Rated Working VoltageAC 220V-240V, 50Hz
Power7W
Insulation ClassClass H
Ambient Temperature (TA)70°C
Fluid Temperature (TF)60°C
Duty CycleED100%
PressureLow Pressure
Medium TypeClean water / Low-viscosity neutral liquid
Pump Body MaterialPlastic
Weight43.4g
CertificationCE
OriginChina Mainland

Note: Specific flow rate, output pressure, medium temperature range, and inlet/outlet connection caliber should be filled in according to actual product specifications if not explicitly listed on the label.

8. User Tips

  • Always Prime: Before first use or after long periods of inactivity, ensure the pump is primed by injecting liquid into the flow channel to prevent dry running and potential damage.
  • Use a Filter: Installing a small filter at the inlet can significantly extend the pump's lifespan by preventing solid impurities from entering and damaging internal components.
  • Check Connections: Regularly inspect all pipeline connections for tightness to prevent leaks and ensure stable operation.
  • Proper Ventilation: Ensure adequate space around the pump, especially the coil, for proper heat dissipation during operation.

9. Warranty & Support

Warranty Terms

  1. The electromagnetic pump enjoys a 12-month limited warranty from the delivery date under standard installation and normal rated working conditions.
  2. Free repair or replacement service is available for failures caused by raw material defects and manufacturing quality problems.
  3. The following situations are excluded from the warranty scope:
    • Coil burnout, plunger jamming, and sealing damage caused by mismatched voltage, dry operation, and reverse pipeline connection.
    • Blockage and abrasion damage caused by conveying liquid with solid impurities without filter protection.
    • Damage caused by artificial disassembly, violent impact, liquid immersion, and corrosive medium erosion.
    • Natural wear of consumable parts such as sealing rings and gaskets.