1. Introduction
The FC-7668Pro is an intelligent alarm control system designed for comprehensive security, integrating burglarproof, fireproof, and gas leak detection capabilities. It supports both wired and wireless alarm modes, utilizing advanced BUS zone and multi-bit random code-hopping technologies for enhanced security and reliability, effectively minimizing false alarms and interference. This system is compatible with SIA2013 and CID protocols, making it suitable for a wide range of applications including residential communities, villas, shops, and offices.
Key Features:
- Zone Configuration: Supports 8 independent zones, 64 wireless zones, 16 wired zones, 128 485 bus expansion zones, 48 keyboard expansion zones, 64 single bus zones, and 192 CAN bus zones, totaling 512 channels.
- Defense Zone Types: Includes wired (1-16), wireless (17-80), keyboard expansion (81-128), bus expansion (129-256), single bus (257-320), CAN bus (321-512), keyboard defense (513-528), wireless siren (529-532), remote controls (533-548), platform (550), key defense (552), web client (555), voice phone (560-575), timed arming/disarming (580-583), main user password (590), and 32 user passwords (591-622).
- User Management: Features 1 web page administrator account, 1 system administrator password, 1 main user account, and 32 ordinary user accounts. All accounts except the system administrator can log in to the webpage (ordinary users require main user permissions).
- Device Support: Compatible with 8 remote controls, 4 two-way wireless sirens, 16 keyboards, and 32 radio switches.
- Communication: Supports 2 network alarm receiving platforms and 2 telephone alarm receiving platforms, configurable for backup or dual alarm modes. Up to 16 personal phones can receive voice and text messages. Mobile phone APP remote control and alarm information push are also supported.
- Timing Functions: Offers 4 groups of timing arming and disarming times, assignable to any one or several partitions.
- SIM Card: Supports one SIM card slot (SIM Card 2 for 4G version; 2G version is not supported).
Important Warnings:
- Do not disassemble or modify the device, as this may lead to danger or damage.
- Avoid placing metal, water, or combustible materials inside the panel to prevent short circuits or fire.
- Do not drop or subject the device to strong impacts.
- Avoid installation near strong magnetic fields, which can cause instability.
- Keep the device dry and clean. Do not install in areas with oily fumes, water vapor, or excessive dust.
- Keep away from direct sunlight, heat sources, and high-temperature equipment like heating stoves or spotlights.
- When cleaning, use a soft cotton cloth. For stubborn dirt, a mild detergent may be used.
- Do not use gasoline, paint thinner, or other harsh chemicals, as they can cause damage or paint peeling.
2. Setup Instructions
2.1. Package Contents
Before beginning installation, please verify that all components are present:
- Control Panel main board with Cabinet: 1 unit
- Wired Touch LCD Control Keypad: 1 unit
- AC/AC Transformer: 1 unit
- Accessories: 1 Antenna, 1 bag of EOL Resistors
Note: A backup battery is not included and must be purchased separately. PB-403R remote controllers are also not included.
2.2. SIM Card Installation
The alarm panel uses a Micro SIM card for GSM communication. Ensure the SIM card is inserted correctly before powering on the device.
- Locate the SIM card holder.
- Push backwards the lid and pull it up.
- Insert the Micro SIM card into the slot.
- Cover the lid well to secure the SIM card.

2.3. Wiring Instructions
Carefully follow the wiring diagram for connecting the various components to the FC-7668Pro control panel. Proper wiring is crucial for the system's functionality.

Power Supply: The system requires a 15VDC/3A switch power supply. Only use a 12VDC 7Ah sealed lead-acid battery for backup, replacing it every 3-5 years. The maximum rechargeable current for the battery is 350mA.
Siren Connection: If not connecting a siren, a 2.2K resistor must be connected to the siren terminals to clear any siren fault indications.
Keypad Connection: The keypad connects to the host control panel. If using multiple keypads, ensure each has a unique dialing address and is connected in parallel to the host's communication port. Unused keypads should be disabled in the host's engineering settings to maintain optimal response speed.

Bus Zone Expansion Module (FC-7601):
- The FC-7601 is a DIP-type single address code zone module with a 10K resistance.
- It extends the address range from 1-128.
- Wiring: Red (DC+), Brown (DC-), Yellow (RS487a), White (RS487B), Green (ZONE TEST), Brown Cable (IS GND).
- Operating Voltage: DC8.5-24V.
- DIP Switch 1 controls tamper checking (ON for enabled, OFF for disabled).
- DIP Switches 2-8 set the address code (OFF enables, ON disables, count by Binary). For example, address 18 is set by DIP 4 and 8 OFF.
- Bus zones 41-128 are disabled by default and must be enabled before use.

2.4. App Download and Installation
The system supports mobile application control. Download the official app by scanning the QR codes below or searching for "Smart Security" in your app store.

After installation, click the app icon to enter settings.

3. Operating Instructions
3.1. Remote Phone Control
You can control the alarm system remotely via phone calls:
- Dial the phone number of the alarm panel.
- The alarm panel will answer after 7 rings (default setting).
- Enter the user password (default: 1234).
- Use the following commands:
- Press 1 to arm the area.
- Press 2 to disarm the area.
- Press 3 to stay arm the area.
- Press 4 to check the area status.
- Press 0 to hang up.

3.2. Alarm Call Handling
When an alarm is triggered, the panel will call the user's pre-set phone number(s). Follow the voice guidance:
- Press 1 to cancel the alarm.
- Press 2 to inquire about the alarm event.
- Press 3 to arm the system.
- Press 4 to disarm the system.
- Press 5 to stay arm the system.
- Press 6 to enable the siren.
- Press 7 to disable the siren.
- Press 0 to disconnect.

3.3. GSM SMS Remote Control
You can send SMS commands to the alarm panel for remote control. The default password is 1234 (no space). The panel will reply with an SMS message if the command is accepted.
- Arm Command:
#PASSWORD:1234#ARMED AREA X(X=1--4)# - Disarm Command:
#PASSWORD:1234#DISARM AREA X(X=1--4)# - Stay Arm Command:
#PASSWORD:1234#STAY AREA X(X=1--4)#
Replace 'X' with the desired area number (1 to 4).
3.4. Web IE Introduction
The alarm system can be configured and managed via a web interface. Open your internet browser and enter the IP address of the alarm control panel. The default user account is 'admin' and the password is '012345'.

Once logged in, you will see the main interface with various settings categories.

Note: Web IE Settings currently do not support RFID setting, Email setting, and Smart home.
3.5. Zone Settings
The Web IE interface allows for detailed configuration of zones, including naming, type, area assignment, siren behavior, and chime settings.


3.6. Timing Arm/Disarm
You can set fixed times to arm or disarm partitions. The system supports four groups of timing arm/disarm settings.

3.7. Device Status and Network Information
The Web IE interface provides real-time data on alarms, wired/wireless devices, and device status including AC power, platform, backup battery, Internet, GSM, and PSTN connections.

3.8. Camera Binding
The system supports binding with up to 32 Meian cameras. After binding, the system will automatically display video from the bound zone when an alarm is triggered.

4. Maintenance
4.1. System Tests
Perform the following tests regularly to ensure proper system function:
- Communication Test:
main user password*1#(Tests communication between alarm panel and CMS). - Battery Test:
main user password*2#(Tests backup battery status. A battery test takes about 4 minutes. If AC power is normal, tests occur every 24 hours. If battery disconnects, tests occur every 10 minutes. If battery voltage is low, tests occur every 60 minutes. If AC power fails, tests occur every minute.) - Siren Test:
main user password*3#(Tests communication between siren and alarm panel). - Walk Test:
main user password*4#(Disarm all areas before starting a walk test).
4.2. Cleanliness of Control Main Machine
The control panel may accumulate dust or fingerprints over time. To clean it:
- Use a soft cotton cloth or sponge.
- Do not use any lubricants, kerosene, acetone, or strong gels, as these can damage the appearance and the transparency of the top window.
4.3. Event Log
The system stores up to 800 event logs, which can be accessed via the web interface to review system recordings, alarms, and user activities.

5. Troubleshooting
5.1. Error Display Settings
The keypad LCD will display fault information if the network cable or SIM card is not properly inserted or functioning. Check these connections and resolve any issues. By default, all fault checkmarks are displayed except for GSM and telephone line faults. After making changes, click 'Save'.

5.2. Limitations of the Product
While the FC-7668Pro is a high-standard product, certain limitations may lead to false alarms or missed alarms:
- Lack of Maintenance: Regular maintenance and testing are crucial. Detector sensitivity and siren functionality may decrease over time without proper checks.
- Power Supply Issues: The panel may not function normally if there is no power input or insufficient backup battery power.
- Telephone Line Failure: If the telephone line is cut, the panel cannot send alarm signals via PSTN.
- Smoke Detector Placement: Smoke detectors may not alarm if the smoke source is too far from the detector.
- Unmonitored Entry Points: The system will not detect intrusions through doors or windows that are not monitored.
- System Bypass Knowledge: If an intruder knows how to bypass the system, its effectiveness will be compromised.
6. Technical Specifications
General Information:
- External AC Power Supply: Input 110-240V AC, Output 15V DC/3A
- Built-in Rechargeable Battery: 12V/7AH (not included)
- Battery Standby Time: 16 hours
- Frequency: 433MHz/868MHz (for wireless components)
- Signal Transmit Distance: 100 to 120 meters (in open areas)
- Method of Alarming Dial: DTMF GSM or GPRS
- Communication Protocol with CMS: Ademco Contact ID
- DTMF Dial Frequency Variation: ≤1.5%
Physical Performance:
- Operation Temperature Range: 0°C to 45°C (32°F to 120°F)
- Storage Temperature Range: -20°C to 60°C (-4°F to 140°F)
- Relative Humidity: 85% at 30°C (86°F)
Product Dimensions:
- Size: 25X19X3CM
- Weight: 1.969 kg (packaged)
7. Warranty and Support
For any technical assistance, troubleshooting, or inquiries regarding your FC-7668Pro alarm system, please contact your seller or the manufacturer's support channels. Keep your purchase records handy for faster service.
A comprehensive user manual in PDF format is available for detailed instructions and advanced configurations. You can access it via the following link: FC-7688 Plus User Manual (PDF)
For visual guides and tutorials, you can search for "FC7668" on YouTube or visit the official YouTube channel: YouTube Channel
8. User Tips
- App Installation: If you encounter any issues during app installation, reach out to the seller for prompt assistance. They are known for quick and helpful responses.
- App Name: The recommended mobile application for this system is "Smart Home Security".
- Roller Shutter Contacts: The system is designed to recognize fast contacts, such as those used for roller shutters, ensuring quick detection.