1. Introduction
The ZHRIVOER XB2 series push button switches are designed for use in industrial control circuits. They are suitable for AC 50Hz or 60Hz systems with a rated operational voltage up to 380V, and DC systems with an operational voltage up to 220V. These switches are commonly used for controlling magnetic starters, contactors, relays, and other electrical circuits. The design and functionality conform to the GB14048.5-2001 standard.
2. Safety Information
- Always disconnect power to the circuit before installing, wiring, or performing maintenance on the switch.
- Installation and wiring should be performed by qualified personnel in accordance with all local and national electrical codes.
- Ensure the switch's voltage and current ratings match the application requirements.
- Do not operate the switch in environments exceeding its specified temperature or protection ratings (IP40/IP65).
- Verify all connections are secure to prevent short circuits or loose contacts.
3. Product Overview
The XB2 series features a 22mm mounting diameter and includes various types of push buttons such as momentary (self-resetting) actions. Available symbols include Start, Stop, 'I', 'O', and directional arrows. The switch assembly typically consists of a button actuator and a contact block (or multiple blocks).

Figure 3.1: Assortment of XB2 push buttons (Start, Stop, I, O, arrows) and contact blocks.
Contact blocks are available in Normally Open (NO) and Normally Closed (NC) configurations. The specific type is usually marked on the block itself.

Figure 3.2: Close-up view of contact blocks, showing ZB2-BE102C (NC) and ZB2-BE101C (NO) types.
4. Setup and Installation
4.1 Mounting
- Ensure the control panel has a standard 22mm diameter cutout for the switch.
- Insert the push button actuator through the cutout from the front of the panel.
- Secure the actuator with the provided locking nut from the rear of the panel.
- Attach the contact block(s) to the rear of the actuator assembly, ensuring they are correctly oriented and securely fastened.
4.2 Wiring
Proper wiring is crucial for the correct operation of the switch. Refer to the wiring diagram below to connect the contact blocks according to your application's requirements. Contact blocks are typically marked with their type (NO - Normally Open, NC - Normally Closed) and terminal numbers.

Figure 4.1: Wiring Diagram Table
Wiring Diagram Details:
| Contact Type | Default State / Schematic Diagram | Pressed State / Schematic Diagram |
|---|---|---|
| 1NO1NC (1 Normally Open, 1 Normally Closed) | Green Open, Red Closed Schematic: (Green contact open, Red contact closed) | Green Closed, Red Open Schematic: (Green contact closed, Red contact open) |
| 2NO (2 Normally Open) | Green Open, Green Open Schematic: (Both Green contacts open) | Green Closed, Green Closed Schematic: (Both Green contacts closed) |
| 2NC (2 Normally Closed) | Red Closed, Red Closed Schematic: (Both Red contacts closed) | Red Open, Red Open Schematic: (Both Red contacts open) |
- Normally Open (NO): The circuit is open (no current flow) when the button is not pressed. It closes (allows current flow) when the button is pressed.
- Normally Closed (NC): The circuit is closed (allows current flow) when the button is not pressed. It opens (stops current flow) when the button is pressed.
5. Operating Instructions
The XB2 series switches are primarily momentary/self-resetting types. This means the switch returns to its default state once the pressure on the button is released.
- To Activate: Press the button firmly. The contacts will change state (NO closes, NC opens).
- To Deactivate: Release the button. The contacts will return to their default state (NO opens, NC closes).
- Symbol Interpretation: Buttons marked 'Start' or 'I' typically use NO contacts to initiate a process. Buttons marked 'Stop' or 'O' typically use NC contacts to halt a process. Arrow symbols indicate direction or specific functions within a control scheme.
6. Maintenance
- Regularly inspect the switch for any signs of physical damage, wear, or loose connections.
- Keep the switch surface clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
- Do not use abrasive cleaners or solvents, as these may damage the plastic components.
- Ensure the operating mechanism moves freely without obstruction.
7. Troubleshooting
- Switch Not Responding:
- Check if power is supplied to the circuit.
- Verify all wiring connections are secure and correct according to the diagram.
- Inspect the contact block for any visible damage or misalignment.
- Button Sticking or Not Resetting:
- Check for any physical obstructions around the button actuator.
- Ensure the mounting nut is not overtightened, which could impede button movement.
8. Specifications
| Parameter | Value |
|---|---|
| Basic Spec Code | 22mm |
| Protection Grade | IP40, IP65 |
| Switch Rating (AC-15) | 220V/6A, 380V/4A, 660V/2A |
| Switch Rating (DC-13) | 24V/6A, 48V/3A, 110V/1A, 220V/0.5A |
| Contact Resistance | Hard silver contacts ≤550MΩ |
| Max. Insulation Voltage | AC 2500V 50Hz~1min |
| Mechanical Life | General button: 1 million times; Key knobs, Knobs, Emergency button, Self-locking button: ≥ 500,000 times |
| Electrical Life | More than 100,000 times (AC220V6A) |
| Conventional Free Air Thermal Current (Ith) | 10A |
| Rated Insulation Voltage (Ui) | AC660V |
| Service Temperature | -25°C ~ +55°C |
| Material | Plastic |
| Certification | CCC, CE, ROHS |
9. User Tips
- Always double-check the contact type (Normally Open or Normally Closed) of your switch before wiring to ensure it matches your intended circuit function.
- For applications requiring specific visual feedback, ensure the chosen button color and symbol clearly indicate its function.
10. Warranty and Support
This ZHRIVOER XB2 series push button switch comes with a 2-year warranty from the date of purchase. For any technical assistance, warranty claims, or support inquiries, please contact your seller or the manufacturer directly. Please provide your purchase details when seeking support.