1. Introduction
The Hi-Link 2W ultra-small series module power supply is a compact, high-efficiency AC/DC power module designed by Shenzhen Hi-Link Electronic Co., Ltd. This series offers a global input voltage range, low temperature rise, minimal power consumption, high efficiency, high reliability, and high safety isolation. It is widely utilized in smart home applications, automation control, communications equipment, instrumentation, and other industries.
This manual provides essential information for the safe and effective use of your HLK-2M03 series power supply module.
Product Overview Video
Video: An overview of the Hi-Link AC/DC isolated small power converter modules, showcasing various models and their compact design.
2. Product Features
- Ultra-thin, ultra-small, smallest volume design.
- Global universal input voltage (90~245Vac).
- Low power consumption, green environmental protection, no-load loss <0.1W.
- Low ripple, low noise output.
- High output short circuit and over-current protection with automatic self-recovery.
- High efficiency, high power density.
- Input and output isolation voltage of 3000Vac.
- 100% full load aging and testing.
- High reliability, long life design, with continuous working time greater than 100,000 hours.
- Meets UL, CE requirements; product design adheres to EMC and safety testing requirements.
- Utilizes high-quality environmentally friendly waterproof plastic potting, providing moisture, vibration, water, and dust resistance to meet IP65 standards.
- Economic and cost-effective solution.
- Operates without the need for external circuitry.
- 1-year quality guarantee period.
3. Specifications
3.1. Product Models and Output Characteristics
| Model | Size (mm) | Output Power (W) | Output Voltage (V) | Output Current (mA) |
|---|---|---|---|---|
| HLK-2M03 | 30.5 * 16.5 * 19 | 2 | 3.3 | 600 |
| HLK-2M05 | 2 | 5 | 400 | |
| HLK-2M09 | 2 | 9 | 230 | |
| HLK-2M12 | 2 | 12 | 170 | |
| HLK-2M15 | 2 | 15 | 130 | |
| HLK-2M24 | 2 | 24 | 83 |
3.2. Input Features
| Item | Technical Parameters | Units |
|---|---|---|
| Rated input voltage | 100-230 | Vac |
| Input voltage range | 90-245 | Vac |
| Maximum input current | ≤0.2 | A |
| Input inrush current | ≤10 | A |
| Rated input voltage | ≤250 | Vac |
| Input low start | ≤50 | mS |
| Input low voltage efficiency | Vin=110Vac, Output full load ≥69 | % |
| Input high voltage efficiency | Vin=220Vac, Output full load ≥70 | % |
| Long-term reliability | MTBF≥100,000 | h |
| External fuse recommended | 0.5A/250Vac | Slow blow |
Note: Tested at room temperature.
3.3. Environmental Conditions
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| Working temperature | -25 to +60 | °C | |
| Storage temperature | -40 to +80 | °C | |
| Relative humidity | 5-95 | % | |
| Thermal methods | Natural cooling | ||
| Atmospheric pressure | 80-106 | Kpa | |
| Altitude | <2000 | m | |
| Vibration | 10~500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes | Meets requirements for secondary road transportation |
3.4. Dimensions and Weight

Diagram: Top, front, and side views of the HLK-2M03 module with dimensions in millimeters. The diagram shows pin functions: Pin 1 (AC), Pin 2 (AC), Pin 3 (-Vo), Pin 4 (+Vo).
| Pin Function | Pin Number |
|---|---|
| AC | 1 |
| AC | 2 |
| -Vo | 3 |
| +Vo | 4 |
- Dimensions: 30.5 * 16.5 * 19 mm (Length * Width * Height)
- Weight: 18 ± 1g
- Dimensional error: ±1mm (length, width, height, pin spacing)
- Pin length error: ±1mm
- Pin diameter error: -0.2mm
Note: The dimensions on the drawing are for reference only. The actual dimensions shall be subject to the physical product.
4. Setup and Installation
4.1. Typical Application Circuit

Diagram: Typical application circuit for the HLK-2M03 series power module. This diagram illustrates the recommended connections for input (LO, NO) and output (+Vo, -Vo), including a fuse (F1), varistor (MOV1), safety capacitor (C1), common-mode inductor (L1), and filter capacitor (C2).
4.2. Input Components
| Component / Recommended Device | Function | Recommended Value |
|---|---|---|
| F1 / Fuse | Protects the circuit from damage when the module is working incorrectly. | 1A/250Vac, Slow fuse |
| MOV1 / Varistor | Protects the module from cumulative surge. | 10D561K |
| C1 / X Safety capacitance | Filtering, safety protection (EMC certification). | 0.1uF/275Vac |
| L1 / Common-mode inductance | EMI filtering. | Inductance: 10-30mH, test requirements: 1KHZ/0.3V, current: 100-500mA |
Notes:
- Fuse and varistor are basic protective circuits and must be connected.
- If authentication/certification is required, the safety capacitance and common-mode inductance cannot be omitted.


Images: Examples of safety capacitance and common-mode inductance components.
4.3. Output Components
| Component / Recommended Device | Function | Recommended Value |
|---|---|---|
| C2 / Filter capacitor | Output ripple can be controlled to 30mV after adding this capacitor. | Aluminum electrolytic capacitance, capacity 100-220 µF, voltage reduction greater than 75% |
| RL / Load | Load connection. |
5. Operating Guidelines
The HLK-2M03 series power module is designed for continuous operation within its specified environmental and electrical parameters. Ensure proper ventilation and avoid exceeding the maximum load conditions to maintain optimal performance and longevity.
5.1. Input Voltage and Load Characteristics

Graph: Illustrates the relationship between input voltage (Vac) and the maximum permissible load (%). The module maintains stable output across a wide input voltage range, with load capacity potentially varying at the extremes.
5.2. Working Temperature and Load Characteristics

Graph: Shows how the maximum permissible load (%) changes with the ambient working temperature (°C). Derating of the load may be necessary at higher temperatures to prevent overheating and ensure reliable operation.
6. Maintenance and Storage
The HLK-2M03 series power modules are designed for high reliability and require minimal maintenance. However, proper handling and storage are crucial for their longevity.
6.1. General Care
- Keep the module clean and free from dust and debris.
- Avoid exposing the module to extreme temperatures or humidity outside the specified operating and storage ranges.
- Ensure adequate ventilation when the module is in operation to facilitate natural cooling.
6.2. Storage
Product storage must meet the requirements of GB3873. Key considerations include:
- Store in a dry, cool environment.
- Avoid direct sunlight and sources of excessive heat.
- Protect from mechanical shock and vibration.
- Maintain relative humidity within the specified storage range (-40 to +80 °C, 5-95% RH).
7. Troubleshooting and Safety Features
The HLK-2M03 series modules incorporate several safety features to ensure reliable operation and protection against common electrical faults.
7.1. Output Over-Current Protection
The module is designed to protect against over-current conditions. If the output current exceeds 150-200% of the maximum rated load, the protection mechanism will activate. This prevents damage to the module and connected devices.
7.2. Output Short Circuit Protection
In the event of a direct short circuit at the output, the module will automatically enter a protected state. Normal operation will resume automatically once the short circuit condition is removed. This feature ensures no damage to the entire device.
7.3. Input Fuse Protection
An external 0.5A/250Vac slow-blow fuse is recommended for the input to protect the circuit from damage due to incorrect operation or fault conditions.
7.4. Surge Protection
A varistor (MOV1) is recommended at the input to protect the module from cumulative surge events.
8. Safety and Compliance
8.1. Certification
Product design meets UL and CE safety certification requirements. (Note: UL and CE certifications are typically obtained by the customer and require design adherence to reference circuits.)
8.2. Safety and Electromagnetic Compatibility (EMC)
- The input design incorporates a UL listed 1A fuse.
- The PCB board is made of double-sided copper clad foil with a material fire resistance grade of 94-V0.
- Safety standard compliance: UL1012, EN60950, UL60950.
- Insulation voltage I/P-O/P: 2500Vac.
- Insulation resistance I/P-O/P: >100M Ohms / 500Vdc at 25°C, 70% RH.
- Conduction and radiation meet EN55011, EN55022 (CISPR22).
- Electrostatic discharge: IEC/EN 61000-4-2 level 4 (8kV/15kV).
- Radio frequency radiation immunity: IEC/EN 61000-4-3.
9. Warranty and Support
The HLK-2M03 series power supply module comes with a 1-year quality guarantee period from the date of purchase.
For technical support, inquiries, or warranty claims, please contact Shenzhen Hi-Link Electronic Co., Ltd. using the information below:
- Address: 17F, Building E, Xinghe WORLD, Minzhi Street, Longhua district, Shenzhen 518131, China
- Telephone: 0755-23152658
- Email: sales@hlktech.com
- Website: www.hlktech.net
For the full user manual in PDF format, please refer to the official documentation: HLK-2M03 Series User Manual (PDF)