1. Safety Information
WARNING: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or play pens. This bag is not a toy.
This device is CE certified, indicating compliance with European safety, health, and environmental protection requirements.

Recycling Information: This appliance, its accessories, cords, and batteries are recyclable. Please dispose of them at designated collection points. Prioritize repair or donation of your device. Packaging elements should be separated and deposited in the sorting bin.
Precautions
- Do not place the device near flammable materials.
- Ensure adequate ventilation during operation.
- Disconnect from power and store properly when not in use for extended periods.
Applicable Regulations and Harmonized Standards
- Low Voltage Directive 2014/35/EU
- Electromagnetic Compatibility Directive 2014/30/EU
- Restriction of the use of certain hazardous substances (RoHS) Directive 2011/65/EU
2. Product Overview
The TOMZN DIN Rail Adjustable Over and Under Voltage Protective Device (Model: TOVPD1-60-EC) is designed to protect electrical circuits from damage caused by voltage fluctuations. It automatically cuts off the circuit when the voltage is too high or too low, and can also provide over-current protection.
This device is suitable for various applications requiring stable power supply and protection against electrical anomalies.
Video: Product demonstration showing the device in various settings.
3. Key Features
- Over-voltage protection: Automatically disconnects the circuit when voltage exceeds a set limit.
- Under-voltage protection: Automatically disconnects the circuit when voltage drops below a set limit.
- Over-current protection: Disconnects the circuit if current exceeds the adjustable limit.
- Automatic recovery: Restores power once voltage and current return to normal levels after a set delay.
- Real-time Voltage display: Shows the current voltage in the circuit.
- Real-time Current display: Shows the current flowing through the circuit.
- Voltage calibration: Allows for fine-tuning of voltage readings (adjustable by ±10%).
- Restore factory settings: Option to reset all parameters to default.
- Fault inquiry: Function to check the latest fault information.

Image: Visual representation of key features including current/voltage display, over/under voltage protection, and automatic reset.
4. Specifications

Image: Detailed product parameter table for the TOVPD1-60 model.
| Parameter | Value | Default |
|---|---|---|
| Brand | TOMZN | |
| Model No. | TOVPD1-60-EC | |
| Input Voltage | AC 80-300V | |
| Rated Current (Adjustable) | 1-40A / 1-63A / 1-80A / 1-100A | 40A / 63A / 80A / 100A (depending on model variant) |
| Over-voltage protection value | 230V~300V~OFF | 270V |
| Over-voltage recovery value | 75-295V | 265V |
| Over-voltage protection action time | 0.1s~30s | 0.5s |
| Over-voltage recovery delay time | 1s~500s | 30s |
| Under-voltage protection value | 80-300V~OFF | 170V |
| Under-voltage recovery value | 85-305V | 175V |
| Under-voltage protection action time | 0.1s~30s | 0.5s |
| Under-voltage recovery delay time | 1s~500s | 30s |
| Over-current protection value | 1-40A / 1-63A / 1-80A | 20A / 40A / 60A (depending on model variant) |
| Over-current protection action time | 0.1s~30s | 0.5s |
| Over-current recovery delay time | 1s~500s | 30s |
| Power-on delay time | 1s~500s | 10s |
| Continuous over current faults times | 1-20 times | OFF |
| Power consumption | ≤2W | |
| Electrical and mechanical life | ≥100,000 cycles | |
| Boundary dimension | 86 x 38 x 68mm | |
| Installation | 35mm DIN rail | |
| Wiring | Over-entering down-out | |
5. Setup
Initial Installation
- Upon receiving the product, it is highly recommended to have a qualified electrical professional perform the installation and initial setup.
- Connect the equipment in accordance with the provided wiring diagram specifications.
- Mount the device securely on a 35mm DIN rail.
Wiring Diagram
The device uses an 'Over-entering down-out' wiring method. Ensure correct connection of Live (L) and Neutral (N) input and output lines.

Image: Example wiring diagram for connecting the protective device with other circuit components. When the power supply is input through the L and N lines, screw down to penetrate the insulating layer of the power lines.
DIN Rail Mounting
The device is designed for easy installation on a standard 35mm DIN rail. The rail buckle design ensures the product is stuck firmly.

Image: The device securely mounted on a DIN rail, highlighting its compatibility with standard electrical enclosures.
6. Operating Instructions
After installation, adjust the equipment parameters according to your specific requirements.
Controls and Display

Image: Front panel layout with input/output terminals, digital displays for voltage and current, work indicators, and control buttons.
- N input / L input: Terminals for neutral and live power input.
- Real-time voltage display: Red digital display showing current voltage.
- Real-time current display: Green digital display showing current amperage.
- Work indicator: LEDs indicating over-voltage (>V), under-voltage (<V), over-current (>A), and power status.
- SET button: Press and hold for more than 3 seconds to enter the setting state.
- UP and DOWN buttons: Used to adjust different parameter values in the setting state.
Parameter Adjustment
To change setting values, press the SET button to enter the setting mode, then use the UP and DOWN keys to adjust the desired parameter. Press SET again to confirm and exit settings.

Image: Flowchart detailing the steps and parameters for adjusting the device settings, including voltage and current protection thresholds and delay times.
- Power-on delay time (A1): 1-500 seconds.
- Over-voltage protection value (A2): 80-300V (OFF).
- Over-voltage recovery value (A3): 75-295V.
- Over-voltage recovery delay time (A4): 1-500 seconds.
- Over-voltage protection action time (A5): 0.1-30 seconds.
- Under-voltage protection value (A6): 80-300V.
- Under-voltage recovery value (A7): 85-305V.
- Under-voltage recovery delay time (A8): 1-500 seconds.
- Under-voltage protection action time (A9): 0.1-30 seconds.
- Over-current protection value (A10): 1-40A / 63A / 80A.
- Over-current recovery delay time (A11): 1-500 seconds.
- Over-current protection action time (A12): 0.1-30 seconds.
- Voltage calibration (A13): Adjusts voltage reading.
- Continuous over current faults times (A14): 1-20 times.
- Current calibration (A15): Adjusts current reading.
- Manual switch (OFF): Turn off the protection function by pressing the power key.
To restore factory settings: Press the DOWN button for more than 12 seconds.
7. User Tips
- Many users find this device easy to set up and operate, performing as described.
- Ensure all connections are secure and follow the wiring diagram precisely to avoid issues.
- For optimal performance, verify that the selected current rating matches your circuit requirements.
8. Troubleshooting
Fault Inquiry
To query the latest fault, press the UP button for more than 6 seconds.
General Troubleshooting Steps
- No Power/Display: Check input wiring (L and N) and ensure power supply is active. Verify connections are tight.
- Device Trips Frequently: Review your set over-voltage, under-voltage, and over-current parameters. They might be too sensitive for your load or power conditions. Adjust delay times if necessary.
- Incorrect Voltage/Current Readings: Use the voltage calibration (A13) and current calibration (A15) functions to fine-tune the readings if you have a known accurate reference meter.
- Device Not Recovering: Check the recovery delay times for over-voltage, under-voltage, and over-current. Ensure the fault condition has cleared and enough time has passed for recovery.
- Protection Not Activating: Double-check that the protection values are set correctly and not 'OFF'.
If issues persist after basic troubleshooting, consult a qualified electrician or contact customer support.
9. Maintenance
- Regular Inspection: Periodically check the device and its connections for any signs of wear, damage, or loose wiring.
- Cleaning: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Storage: If the device is not in use for an extended period, disconnect it from the power supply and store it in a dry, cool place.
- Ventilation: Ensure the installation area has adequate ventilation to prevent overheating.
10. Warranty and Support
This product is manufactured in compliance with international standards, including the Low Voltage Directive 2014/35/EU, Electromagnetic Compatibility Directive 2014/30/EU, and RoHS Directive 2011/65/EU.
For specific warranty details, technical support, or service inquiries, please refer to the official TOMZN product documentation or contact the seller/manufacturer directly.
A user manual in PDF format is available for download: Download User Manual (PDF)
11. Frequently Asked Questions (FAQ)
- Q: Where is this product applicable?
- A: This product is applicable in places that require voltage protection for electrical circuits and connected devices.
- Q: Under which category does this product fall?
- A: The product falls under the Voltage Protector category, often also referred to as a Voltage Relay.