MiLESEEY TR120 / TR256

Contents

Mileseey TR120 / TR256 Professional Thermal Imager User Manual

Your comprehensive guide to operating and maintaining your thermal imager.

1. Product Description

Thank you for choosing the MILESEEY TR120 Handheld Thermal Imager. Please read this user manual carefully before use and keep it safe for future references.

The TR120 is a dual-camera thermal imager featuring both infrared and visible light imaging modes. Equipped with a large 3.5-inch LCD display, it provides a wider viewing area, making it easier to locate fault points and analyze problem zones accurately. The customizable emissivity setting further enhances temperature accuracy for different materials and surfaces.

Designed for practical on-site use, the TR120 allows users to capture, store, and export images conveniently via USB cable or SD card—ideal for inspection documentation and maintenance analysis. With automatic hot and cold spot tracking, as well as independent high and low temperature alarms, it ensures precise and efficient temperature monitoring in real time.

Powered by a built-in 5000 mAh 26650 lithium battery and Type-C charging port, the TR120 delivers long-lasting and eco-friendly performance. The integrated 3W LED light provides clear visibility in dark or confined spaces, making it ideal for nighttime inspections and ensuring safer operation across various work environments.

2. Package Contents

Upon opening your Mileseey TR120 / TR256 package, please ensure all items listed below are present and in good condition:

  • Mileseey TR120 / TR256 Thermal Imager Unit
  • User Manual
  • Wiping Cloth
  • Strap
  • USB Cable
  • Certificate
  • Carrying Case
  • SD Card (SanDisk, if included with your model)
Mileseey TR120 package contents including the thermal imager, manual, wiping cloth, strap, USB cable, certificate, and carrying case.
Image: Contents of the Mileseey TR120 package.
Mileseey TR120 thermal imager inside its protective carrying case.
Image: Mileseey TR120 stored in its carrying case.
Video: Unboxing and overview of the Mileseey TR120 thermal imager and its accessories.

3. Overview

Familiarize yourself with the components and controls of your thermal imager:

Front view of the Mileseey TR120 thermal imager showing the 3.5 inch LCD display, power button, picture history button, return button, set button, and navigation buttons.
Image: Front view of the Mileseey TR120.

Front Panel Controls:

  • 3.5" LCD Display: Main screen for thermal imaging and menu navigation.
  • Power Button: Turns the device on/off.
  • Picture History Button: Accesses saved images.
  • Return Button: Navigates back in menus or exits current function.
  • Set Button: Confirms selections or enters menus.
  • Navigation Buttons: Used for menu navigation and adjusting settings.
Top and side views of the Mileseey TR120 thermal imager showing the LED light, laser lens, thermal camera, visible light camera, lens cover, and capture button.
Image: Top and side views of the Mileseey TR120.

Top and Side Components:

  • LED Light Switch: Activates the integrated LED light.
  • LED Light: Provides illumination in dark areas.
  • Laser Lens: For precise targeting.
  • Thermal Camera: Captures infrared thermal data.
  • Visible Light Camera: Captures standard visual images.
  • Lens Cover: Protects the camera lenses.
  • Capture Button: Takes pictures.
  • Tripod Mount Screw Hole: For mounting the device on a tripod.

4. Setup

4.1. Charging the Device

Open the cover on the top of the device. Connect the device to a power supply via the USB-C cable for charging. *Please use a 5V/2A power adapter only.

Mileseey TR120 thermal imager being charged via USB-C cable, highlighting its 10-hour battery life.
Image: Mileseey TR120 charging via USB-C.

4.2. Power On/Off

Press and hold the Power button (Power button icon) to turn the device on or off.

5. Operation

5.1. Display Icons

The display provides various indicators and information:

Mileseey TR120 display showing various icons and their meanings, including battery level, temperature points, temperature bar, detection distance, emissivity, settings, image mode, palette, alarm, unit, and measurement.
Image: Display icons and their functions.
  • Battery Level Indicator: Shows current battery charge.
  • Lowest/Highest Temperature Point: Indicates specific temperature readings.
  • Highest/Lowest Temperature of the Area: Displays the maximum and minimum temperatures detected in the current view.
  • Temperature Bar: Visual scale of temperature range.
  • Current Detection Distance: Shows the set detection distance.
  • Current Emissivity: Displays the set emissivity value.
  • Settings Icon: Accesses device settings.
  • Image Mode Icon: Changes the image display mode.
  • Palette Icon: Selects different color palettes.
  • Alarm Icon: Indicates alarm status.
  • Unit Icon: Changes temperature units.
  • Measurement Icon: Accesses temperature measurement options.

5.2. Image Capture

Press the Capture button on the side of the device to take pictures and save them to history.

5.3. View/Delete Pictures

Press the Picture History button (Picture history button icon) to view captured images. Use the navigation buttons (▲/▼/◄/►) to browse through pictures. Press the Set button (SET) to choose whether to delete a single image or all images. Press the Set button (SET) again to confirm, and press the Return button (Return button icon) to exit.

5.4. Settings

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Setting'. Press the Set button (SET) again to enter the menu. Use the navigation buttons (▲/▼) to select items and adjust values. Press the Set button (SET) to confirm each selection, or press the Return button (Return button icon) to go back to the previous step.

Settings include:

  • Emissivity (0.01~0.99): Adjusts for different material surfaces.
  • Distance (0.5m~1.2m): Sets the detection distance.
  • HI/LO Alert: Configures high and low temperature alarms.
  • Brightness (Low/Mid/High): Adjusts screen brightness.
  • Date & Time: Sets the device's date and time.
  • Auto Power Off (5Min/10Min/30Min/Off): Configures automatic shutdown.
  • USB Mode (USB Disk/USB Camera): Selects USB connection mode.
  • Factory Reset: Resets all settings to default.
  • Format SD Card: Formats the inserted SD card.
  • Device Info: Displays device information.

Emissivity of Common Objects:

MaterialsEmissivityMaterialsEmissivity
Wood0.85Black paper0.86
Water0.96Polycarbonate0.8
Brick0.75Concrete0.97
Stainless steel0.14Copper oxide0.78
Adhesive tape0.96Cast iron0.81
Aluminium plate0.09Rust0.8
Copper plate0.06Gypsum0.75
Black aluminum0.95Paint0.9
Human skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC plastic0.93

5.5. USB Mode

The device supports two USB modes for data transfer and real-time display:

1. USB Disk Mode

When the USB mode is set to USB Disk, you can view pictures and analyze data on the PC software by connecting the device to your computer with a USB cable.

Note:

  • To switch to USB Disk mode, restart the device first, then connect the USB cable to activate the mode.
  • Do not change the image folder name or image filenames, as this may cause reading errors.

2. USB Camera Mode

When the USB mode is set to USB Camera, connect the USB cable to your computer to enable real-time image projection in the PC software.

Note:

  • To switch to USB Camera mode, power off the device first, then connect the USB cable. The device will automatically start in USB Camera mode.
  • Do not unplug the USB cable during screen projection. When finished, close the projection software first, then unplug the USB cable.

5.6. Image Mode

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Image Mode', and then press the Set button (SET) again to enter the sub-menu. Use the navigation buttons (▲/▼) to select among Digital, Fusion Rate, Fusion Offset, PIP, and Thermal. Press the Set button (SET) or Return button (Return button icon) to confirm and exit.

Examples of different image modes: Digital, Fusion Rate, Fusion Offset, PIP, and Thermal.
Image: Various image display modes.

5.7. Color Palette

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Palette', and then press the Set button (SET) again to enter the sub-menu. Use the navigation buttons (▲/▼) to choose from White Hot, Iron, Tropical, Arctic, Lava, and Rainbow. Press the Set button (SET) or Return button (Return button icon) to confirm and exit.

Six color palettes available on the Mileseey TR120: High Resolution Rainbow, Hot Red, Lava, Rainbow, Iron Oxide Red, and White Heat.
Image: Six color palettes for thermal imaging.

5.8. Unit Switch

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Unit', and then press the Set button (SET) again to enter the sub-menu. Use the navigation buttons (▲/▼) to select between °C and °F. Press the Set button (SET) or Return button (Return button icon) to confirm and exit.

5.9. Alarm Setting

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Alarm', and then press the Set button (SET) again to enter the sub-menu. Use the navigation buttons (▲/▼) to select High Temp Alert and Low Temp Alert, and press the Set button (SET) to enable or disable each option. You can turn on both alerts, either one, or neither depending on your needs.

Mileseey TR120 display showing automatic hot/cold spot tracking and temperature warning in use.
Image: Automatic Hot/Cold Spot Tracker in action.

5.10. Temperature Measuring

Press the Set button (SET) to open the tool bar. Use the navigation buttons (◄/►) to find 'Measurement', and then press the Set button (SET) again to enter the sub-menu. Use the navigation buttons (▲/▼) to choose from Hi/Lo Dot, Center Dot, Region, and Edit Region. Press the Set button (SET) to enable or disable each option. You can choose multiple options, or none, depending on your needs.

*In Edit Region, press and hold Navigation buttons to expand or narrow the range.

6. Maintenance

To ensure accurate measurement results and safety, please use this product in accordance with the user manual. Otherwise, free warranty will not be provided if the product is damaged.

Please use a damp cloth or weak soap liquid to clean the housing. Do not use abrasives, isopropyl alcohol, or solvents to clean the instrument shell, lens, and windows.

Please do not use this product in flammable, explosive, steamy, humid, or corrosive environments.

Please use the correct emissivity to obtain accurate temperature readouts.

When being charged, the internal temperature of the product will rise, which will lead to inaccurate temperature measurement. It is not recommended to take measurements during or right after charging.

Because the power consumption may cause the internal temperature of the product to rise. To ensure measurement accuracy, please warm it up for 10 minutes before measuring if the product has not been used for a long time.

7. Troubleshooting

7.1. Infrared Thermal Map Not Fusing with Visible Light Map

Issue: The infrared thermal map does not align perfectly with the visible light map.

Reason: When shooting at close range, there may be picture dislocation due to the difference in the minimum focus distance of infrared and visible light lenses.

Solution:

  • In case of close observation, the visible light image can be adjusted by pressing the up/down/left/right navigation buttons to complete the fusion.
  • If you are shooting at a long distance, the infrared and visible light images will automatically and completely fuse because they are larger than the focus distance.

7.2. Device Not Turning On (TR120E)

Issue: The TR120E device is not powering on.

Solution:

  • Ensure the device is fully charged. Connect it to a 5V/2A power adapter using the USB-C cable and allow it to charge for a sufficient period.
  • Press and hold the Power button for a few seconds to attempt to power it on.
  • If the issue persists, contact customer support.

8. User Tips

  • The TR120 model with dual cameras is highly regarded for its performance.
  • Users have noted the robust build quality and large screen of the TR256A model.
  • For accurate temperature readings, always ensure the correct emissivity setting is applied for the material being measured.
  • The device is generally well-received for its fast delivery and good quality.

9. Specifications

Below is a detailed comparison of the TR120 and TR256 models, along with the TR120E for reference:

Parameter Comparison List for Mileseey TR120E, TR120, and TR256 thermal imagers, detailing display size, resolution, imaging pixel, spectral response, pixel size, thermal sensitivity, measuring range, palette, alarms, power supply, communication, LED, IP level, working temperature, storage temperature, fall prevention, size, weight, and video output.
Image: Parameter Comparison List for TR120E, TR120, and TR256.
FeatureTR120TR256
IR Resolution120*90256*192
FOV50°x 63.4°N/A
IFOV7.456 mradN/A
NETD< 60mK< 50mK
Frame Rate≤ 20HZ≤ 20HZ
Display3.5" LCD Display, 320*2403.5" LCD Display, 640*480
Temperature Range-20°C to 400°C-20°C to 550°C
Measuring Accuracy-20°C~0°C: ±5°C; 0°C~100°C: ±3°C; 100°C~400°C: ±5%-20°C~0°C: ±5°C; 0°C~100°C: ±3°C; 100°C~550°C: ±5%
Memory8GB8GB
Color Palette66
Distance Range0.5m~1.2m0.5m~1.2m
Visible Light Resolution640*480640*480
Battery Capacity5,000mAh Lithium Battery5,000mAh Lithium Battery
Light3W White LED Light3W White LED Light
Operating Temperature-10°C to 50°C-20°C to 60°C
Storage Temperature-40°C to 70°C-40°C to 70°C
Charging PortUSB(2.0)FSUSB(2.0)FS
Dimensions238*95*85.5mm238*95*85.5mm
Weight540g540g
Fall Prevention1.5m1.5m
Video OutputNoYes

*All data are measured and provided by the MILESEEY Lab; the actual use will be slightly different depending on the specific circumstances.

10. Warranty & Support

Product specifications may change without prior notice; all rights for final interpretation are reserved by Mileseey Technology Co., Ltd. All trademarks, product images, and technical parameters belong to Mileseey Technology Co., Ltd. All rights reserved.

Contact Us:

Mileseey Technology (US) Inc.
Office Addr.: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY, CA 91748

Manufacturer: Shenzhen Mileseey Technology Co., Ltd.
Addr.: No.3601 Block A, Tanglang Town Plaza West, Fuguang Community, Taoyuan Street, Nanshan District, Shenzhen, China

Store: www.mileseeytools.com
Email: mileseeytools@mileseey.com

© 2023 MiLESEEY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.