TOMZN TOVPD3-63VA

Contents

TOMZN TOVPD3-63VA Three Phase Adjustable Over and Under Voltage Protector User Manual

Model: TOVPD3-63VA

1. Safety Information

Warning: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or play pens. This bag is not a toy.

  • Do not place the device near flammable materials.
  • Ensure adequate ventilation during operation.
  • Disconnect from power and store properly when not in use for extended periods.
  • This device operates at high voltage (above 50Vac or 75Vdc). Installation and operation should only be performed by a qualified electrical professional.

This product is certified with CE standards, indicating compliance with European safety, health, and environmental protection requirements.

2. Product Overview

The TOMZN TOVPD3-63VA (and TOVPD3-100VA) is a three-phase adjustable over and under voltage protector with over current protection and automatic recovery. It is designed to safeguard electrical equipment from damage caused by voltage fluctuations and excessive current.

Key Features:

  • Over-voltage protection (Adjustable)
  • Under-voltage protection (Adjustable)
  • Over-current protection (Adjustable)
  • Asymmetry protection
  • Phase sequence protection
  • Adjustable active time and reconnect time
  • Real-time display of working voltage and current
  • Manual calibration of voltage and current
  • Automatic reset function
  • Flame retardant shell
Product Features Icons
Visual representation of key product features.

3. Specifications

Parameter Value
Brand NameTOMZN
Model NumberTOVPD3-63VA / TOVPD3-100VA
TypeVoltage protector, Voltage relay
Rated Voltage220/380V
Rated Supply Voltage3*200V
Operation Voltage RangeAC140V-300V
Rated Frequency50/60Hz
Hysteresis (Over voltage)5V
Hysteresis (Under voltage)3V
Asymmetry Trip Delay10s
Voltage Measurement Accuracy1% (over the whole range)
Rated Insulation Voltage450V
Output Contact1NO
Electrical Life105
Mechanical Life105
Protection DegreeIP20
Pollution Degree3
Altitude≤2000m
Operating Temperature-5°C - 40°C
Humidity≤50% at 40°C
Storage Temperature-25°C - 55°C
Is Smart DeviceNo
Does it include wireless functionality?No
Does it include a Battery?No
Product Parameter Table
Detailed product parameters.
Dimensions of 63A model
Dimensions for the 63A model (approx. 91mm x 90mm x 50mm).
Dimensions of 100A model
Dimensions for the 100A model (approx. 91mm x 102mm x 52mm).

4. Setup

Installation Instructions:

  1. After receiving the product, please have an electrical professional perform the operation.
  2. Connect the equipment in accordance with the wiring diagram specifications provided below.
  3. According to the instructions, adjust the equipment parameters as needed (refer to Section 5: Operating).

Wiring Diagram:

Ensure correct wiring for your specific system (3*220V+N or 380V 3 Phase). The device has IN (input) and OUT (output) terminals, along with N (neutral) and L (line) connections.

General Wiring Diagram
General wiring diagram for the 3 phase voltage current protector.
Detailed Wiring Diagram for 3*220V+N and 380V
Detailed wiring diagram showing connections for 3*220V+N (displaying each phase 220V) and 380V 3 Phase (displaying all 380V).

Note:

  • For 63A/100A With N 220V: Connect to 3*220V+N system. The device will display each phase at 220V.
  • For 63A/100A without N 380V: Connect to a 3 Phase 380V system (L1, L2, L3). The device will display 380V across all phases.

5. Operating

Panel Introduction:

Panel Introduction with Labels
Front panel layout and controls.
  • Voltage Display Screen (V): Shows real-time voltage for L1, L2, L3.
  • Current Display Screen (A): Shows real-time current for L1, L2, L3.
  • Manual switch (Power icon): Turns the device on/off.
  • Menu key (SET): Enters the settings menu and confirms selections.
  • Adjustment key (Up arrow): Increases parameter values or navigates up.
  • Adjustment key (Down arrow): Decreases parameter values or navigates down.
  • Output indication (Line icon): Indicates output status.
  • Over-voltage indication (>U): Lights up when over-voltage protection is active.
  • Under-voltage indication (<U): Lights up when under-voltage protection is active.
  • Over-current indication (>I): Lights up when over-current protection is active.

Parameter Settings and Operating Range:

Use the 'SET' button to enter the menu and the Up/Down arrows to adjust values. Press 'SET' again to confirm and move to the next parameter.

Code Parameter Setting Range Default Value (63A / 100A) Function Description
P1Power-on delay time1s-500s10sTime needed for power-on when power recovers.
U1Over-voltage protection value230V-300V270VWhen voltage is higher than set value, protector cuts off.
U2Over-voltage recovery value225V-295V265VWhen voltage is lower than set value, protector automatically resets.
U3Over-voltage recovery delay time1s-500s30sTime needed for automatic reset after over-voltage.
U4Over-voltage protection action time0.1s-30s1.0sTime for protection action when over-voltage is detected.
U5Under-voltage protection value140V-210V170VWhen voltage is lower than set value, protector cuts off.
U6Under-voltage recovery value145V-215V175VWhen voltage is higher than set value, protector automatically resets.
U7Under-voltage recovery delay time1s-500s30sTime needed for automatic reset after under-voltage.
U8Under-voltage protection action time0.1s-30s1.0sTime for protection action when under-voltage is detected.
U9Three phase voltage error value-9.5% - 9.5%0%Correct the three phase voltage error.
U10Three phase voltage unbalance protection value20V-99V20VWhen three phase voltage unbalance is higher than set value, protector cuts off.
U11Three phase voltage unbalance protection switchON/OFFOFFSwitch on or off the three phase voltage unbalance protection function.
C1Over-current protection value1A-63A (for 63A model) / 1A-100A (for 100A model)30A / 60AWhen current is higher than set value, protector cuts off.
C2Over-current recovery delay time1s-500s30sTime needed for automatic reset after over-current.
C3Over-current protection action time0.1s-30s1.0sTime for protection action when over-current is detected.
C4Three phase current error value-9.5% - 9.5%0%Correct the three phase current error.
C5Times of continuous over current protection0-20OFFWhen continuous over-current exceeds set value, protector cuts off. Needs manual reset if set to a value other than 0.
Phase-loss protectionONONOne of the three-phase voltages is losing, the protector will cut off the line.
Operating Range Table 63A
Operating range and default settings for the 63A model.
Operating Range Table 100A
Operating range and default settings for the 100A model.

6. Maintenance

  • Regularly check the device for any signs of physical damage or overheating.
  • Ensure the installation area has adequate ventilation to prevent heat buildup.
  • Keep the device away from flammable materials.
  • When not in use for extended periods, disconnect the device from power and store it in a dry, safe place.
  • Cleaning should be done with a dry cloth. Do not use liquids or abrasive cleaners.

7. Troubleshooting

  • Device trips unexpectedly: Check the real-time voltage and current readings on the display. Compare them with your set protection values (U1, U5, C1). Verify if there's an actual over-voltage, under-voltage, or over-current condition.
  • Protection activates on a single phase: If protection is triggered by an issue on only one phase (e.g., over-voltage on L1), the device is designed to cut off power to all three phases for comprehensive protection.
  • Display readings seem inaccurate: The device supports manual calibration of voltage and current. Refer to the operating instructions to access the calibration menu and adjust if necessary.
  • Device does not reset after a fault: Check the recovery delay times (U3, U7, C2) in the settings. Ensure sufficient time has passed. If parameter C5 (Continuous Over Current Times) is set to a value other than 'OFF', the device may require manual reset after multiple over-current events.
  • Phase loss detected: If one of the three-phase voltages is lost, the protector will automatically cut off the line. Check your power supply for phase integrity.

8. User Tips

  • Professional Installation: Always have a qualified electrician install and configure this device to ensure safety and proper functionality.
  • Manual Calibration: If you suspect the voltage or current readings are inaccurate, utilize the manual calibration feature. This can be accessed via the 'SET' button and navigating through the menu.
  • Understanding Trip Behavior: Be aware that if any single phase experiences a fault (over-voltage, under-voltage, or over-current), the protector will typically disconnect all three phases to protect the entire system.
  • Environmental Considerations: The device is designed for a wide range of temperatures but ensure it's not exposed to extreme heat or cold beyond its specified operating range (-5°C to 40°C).

9. Warranty & Support

Applicable Regulations and Harmonized Standards:

  • Low Voltage Directive 2014/35/EU
  • Electromagnetic compatibility Directive 2014/30/EU
  • Restriction of the use of certain hazardous substances (RoHS) Directive 2011/65/EU

For detailed information, including comprehensive technical diagrams and advanced settings, a full user manual in PDF format is available. You can reference it here: TOMZN TOVPD3-63VA User Manual (PDF).

10. Product Media

Product Demonstration Video:

A short video demonstrating the TOMZN voltage protector's display and basic operation.

Additional Product Views:

Front view of 63A and 100A models
Front view comparison of the 63A and 100A models.
Over Current Protection Feature
Illustration of the Over Current Protection feature, highlighting automatic power off on overload.
Real-time display and calibration note
Close-up of the real-time voltage and current display, noting the manual calibration capability.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.