Aideepen ACM91 Digital Clamp Meter

Rate this product if you’ve used it
Contents

ACM91 Digital Clamp Meter Multimeter User Manual

Model: ACM91

1. Introduction

The ACM91 Digital Clamp Meter is a versatile and compact tool designed for electrical measurements. It offers a wide range of functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, temperature, non-contact voltage (NCV) detection, and live wire checking. Its auto-ranging capability and clear digital display make it suitable for both professional electricians and DIY enthusiasts.

2. Safety Information

WARNING: To avoid possible electric shock, fire, or personal injury, please read all safety information before you use the product.

  • Always ensure the meter is in good working condition before use.
  • Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
  • Use extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Keep your fingers behind the finger guards on the test probes during use.
  • Do not use the meter if it is damaged or if the insulation is compromised.
  • Always disconnect power to the circuit and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.
  • Ensure the meter is set to the correct function and range before making measurements.
  • Replace the battery as soon as the low battery indicator appears to ensure accurate readings.
  • Adhere to over-voltage protection class CAT III 300V, CAT II 600V.

3. Package Contents

Please check the package for the following items:

  • 1 x ACM91 Digital Clamp Meter
  • 1 x Test Leads (Red and Black)
  • 1 x Thermocouple (for temperature measurement)
  • 1 x User Manual (This document, and a detailed PDF version is available for reference)
  • 1 x Carrying Case

Note: Batteries (2 x AAA 1.5V) are not included due to aviation security regulations.

4. Product Overview

Familiarize yourself with the components of your ACM91 Digital Clamp Meter.

ACM91 Digital Clamp Meter in use on an electrical panel

Figure 4.1: ACM91 Digital Clamp Meter in operation, showing NCV alert.

Dimensions of the ACM91 Digital Clamp Meter

Figure 4.2: Dimensions of the ACM91 Clamp Meter (approx. 17.9 cm length, 6.7 cm width, 3.6 cm thickness).

4.1. Meter Components

  • Clamp Jaw: Used for non-contact AC/DC current measurement.
  • NCV Sensor: Detects non-contact voltage.
  • Display: 6000 counts digital display with backlight. Shows measurement values, units, and function indicators.
  • Function Dial/Buttons: Selects measurement functions (Voltage, Current, Resistance, etc.) and activates features (Hold, Backlight, Zero, etc.).
  • Input Jacks:
    • COM Jack: Common (negative) input for test leads.
    • INPUT Jack: Positive input for voltage, resistance, capacitance, frequency, diode, and continuity measurements.
Close-up of ACM91 display showing units

Figure 4.3: Close-up of the ACM91 display showing various measurement units and indicators.

5. Setup

5.1. Battery Installation

  1. Ensure the meter is turned off.
  2. Locate the battery compartment cover on the back of the meter.
  3. Use a screwdriver to open the battery compartment.
  4. Insert two AAA 1.5V batteries, observing the correct polarity (+/-).
  5. Replace the battery compartment cover and secure it with the screw.

5.2. Connecting Test Leads

For most measurements (voltage, resistance, capacitance, frequency, diode, continuity):

  1. Insert the red test lead into the INPUT jack.
  2. Insert the black test lead into the COM (common) jack.
ACM91 with test leads connected measuring a circuit board

Figure 5.1: Connecting test leads for circuit board measurement.

6. Operating Instructions

The ACM91 features an auto-ranging function, simplifying operation. Select the desired function using the rotary dial.

Icons representing full range of functions

Figure 6.1: Icons representing the full range of functions available on the ACM91.

6.1. AC/DC Voltage Measurement

  1. Set the rotary dial to the V~ (AC Voltage) or V- (DC Voltage) position.
  2. Connect the test leads in parallel to the circuit or component under test.
  3. Read the voltage value on the display.

6.2. AC/DC Current Measurement (via Clamp Jaw)

  1. Set the rotary dial to the A~ (AC Current) or A- (DC Current) position.
  2. Open the clamp jaw and enclose only one conductor of the circuit.
  3. Read the current value on the display. (Minimum 1mA detection).

6.3. DC Microampere (μA) Measurement (via Terminals)

  1. Set the rotary dial to the μA position.
  2. Connect the test leads in series with the circuit.
  3. Read the microampere value on the display. (Minimum 0.1μA detection).

6.4. Resistance (Ω) Measurement

  1. Set the rotary dial to the Ω position.
  2. Ensure the circuit is de-energized.
  3. Connect the test leads across the component to measure resistance.
  4. Read the resistance value on the display.

6.5. Capacitance (F) Measurement

  1. Set the rotary dial to the F position.
  2. Ensure the capacitor is fully discharged before testing.
  3. Connect the test leads across the capacitor terminals.
  4. Read the capacitance value on the display.

6.6. Frequency (Hz) Measurement

  1. Set the rotary dial to the Hz position.
  2. For frequency via terminals, connect test leads to the signal source.
  3. For frequency via clamp jaw, enclose one conductor.
  4. Read the frequency value on the display.

6.7. Temperature (°C/°F) Measurement

  1. Set the rotary dial to the °C/°F position.
  2. Connect the thermocouple to the input jacks (observe polarity if applicable).
  3. Place the thermocouple tip on the object whose temperature is to be measured.
  4. Read the temperature value on the display.

6.8. Continuity Test

  1. Set the rotary dial to the continuity/diode position.
  2. Connect the test leads across the circuit or component.
  3. If the resistance is less than 30Ω, the buzzer will sound, indicating continuity.

6.9. Diode Test

  1. Set the rotary dial to the continuity/diode position.
  2. Connect the red lead to the anode and the black lead to the cathode of the diode.
  3. The display will show the forward voltage drop. Reverse the leads to check for open circuit (OL).

6.10. Non-Contact Voltage (NCV) Detection

  1. Set the rotary dial to the NCV position.
  2. Move the NCV sensor (top part of the clamp) close to the conductor.
  3. The meter will beep and the NCV indicator will light up if AC voltage is detected.

6.11. Live Wire Check

  1. Set the rotary dial to the LIVE position.
  2. Touch the red test lead to the suspected live wire.
  3. The meter will indicate if the wire is live.

6.12. LoZ (Low Impedance) Voltage Measurement

This function helps to eliminate ghost voltages. Select the LoZ function on the dial and measure voltage as usual.

6.13. Data Hold (H)

Press the 'H' button to freeze the current reading on the display. Press again to release.

6.14. Backlight

Press the backlight button to illuminate the display for better visibility in dark conditions. Press again to turn off.

6.15. Auto Power Off

The meter will automatically power off after approximately 15 minutes of inactivity to conserve battery life. Press any button or turn the dial to wake it up.

Usage scenarios for ACM91 clamp meter

Figure 6.2: Various usage scenarios for the ACM91, including voltage and current tests.

7. Maintenance

7.1. Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Keep the input terminals free from dirt and moisture.

7.2. Battery Replacement

When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to Section 5.1 for battery installation instructions.

7.3. Storage

If the meter is not used for a long period, remove the batteries to prevent leakage and damage to the device. Store the meter in its carrying case in a cool, dry place.

8. Troubleshooting

ProblemPossible CauseSolution
No display or dim displayDead or weak batteries; Incorrect battery installationReplace batteries; Check battery polarity
Incorrect readingsWrong function/range selected; Poor test lead connection; External interferenceSelect correct function/range; Ensure good contact; Move away from strong electromagnetic fields
Meter does not respondMeter frozen; Internal faultTurn off and on again; Remove and reinsert batteries; Contact support if problem persists
Buzzer always on during continuity testShort circuit in test leads or circuitCheck test leads for shorts; Inspect circuit for short circuits

9. Specifications

ParameterSpecification
Display6000 Counts Digital Display
DC Current (Jaw)6A/60A/100A (±3.0%+5 counts)
DC Current (μA Terminals)0-200μA (±0.8%+5 counts)
AC Current (Jaw)6A/60A/100A (±2.5%+5 counts)
DC Voltage6V/60V/600V (±1.0%+3 counts)
AC Voltage6V/60V/600V (±1.0%+3 counts)
Low Impedance (LoZ)Max 600V Resolution 0.1V
Resistance600Ω/6kΩ/60kΩ/600kΩ/6MΩ (±1.0%+3 counts), 60MΩ (±1.2%+20 counts)
Capacitance600μF/6000μF (±4.0%+3 counts)
Frequency (Terminals/Jaw)60Hz/1000Hz (±1.0%+5 counts)
Temperature-20°C to 500°C / -4°F to 932°F (±2.0%+2 counts)
Continuity BuzzerSounds if resistance < 30Ω
Jaw Capacity20mm
Power2 x AAA 1.5V Batteries
Dimensions179mm x 67mm x 36mm
Weight137g (without battery)
Safety RatingCAT III 300V, CAT II 600V
Operating Temperature0 - 40 °C

10. User Tips

  • Always read the full user manual before operating the device to understand all functions and safety precautions.
  • Ensure test leads are fully inserted into the correct jacks for accurate and safe measurements.
  • When measuring current with the clamp, ensure only one conductor passes through the jaw for a correct reading.
  • For resistance and capacitance measurements, always ensure the circuit is de-energized and capacitors are discharged.

11. Warranty and Support

For any warranty claims, technical support, or inquiries regarding your ACM91 Digital Clamp Meter, please contact the seller or retailer from whom you purchased the product. Keep your purchase receipt as proof of purchase.

© 2023 Aideepen. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?