1. Introduction
This manual provides instructions for the CFsunbird NE555 Delay Timer Monostable Switch Relay Module (Model HW-010). This module is designed to provide a timed delay before activating a relay, suitable for various applications such as vehicle device control and preventing inrush current in electronic systems. It is available in 5V and 12V operating voltage variants.
2. Safety Information
- Always ensure the power supply voltage matches the module's specified operating voltage (5V or 12V).
- Exercise caution when working with electrical circuits, especially when connecting to AC loads.
- Ensure all connections are secure to prevent short circuits or loose contacts.
- Do not exceed the maximum current and voltage ratings of the relay (10A 250VAC / 10A 30VDC / 10A 125VAC / 10A 28VDC).
- Keep the module away from moisture and extreme temperatures.
3. Product Overview
The HW-010 module features a compact design and is built around the versatile NE555 timer IC. It includes a relay for switching loads, a potentiometer for adjusting delay time, and indicator LEDs for power and relay status.



4. Specifications
| Feature | Specification |
|---|---|
| Main Chip | NE555 |
| Module Dimensions | 6.8 cm x 2.1 cm |
| Operating Voltage | 5V or 12V (variant dependent) |
| Delay Time Range | 0 to 10 seconds (adjustable) |
| Relay Control Capacity | 10A 250VAC / 10A 30VDC / 10A 125VAC / 10A 28VDC (Max 2000W) |
| Indicators | Input Power LED, Relay Status LED |
| Protection | Freewheeling protection for relay |
| Customization | Yes |
| Dissipation Power | 1W |
| Operating Temperature | 1°C (typical, specific range not provided) |
5. Setup and Wiring
The module has clearly labeled terminal blocks for power input and relay output. Refer to the images for visual guidance.

5.1 Power Connection
- Connect the positive (+) terminal of your power supply to the VCC terminal on the module.
- Connect the negative (-) terminal of your power supply to the GND terminal on the module.
- Ensure the power supply voltage matches the module's variant (5V or 12V).
5.2 Load Connection (Relay Output)
The relay provides three terminals for connecting your load:
- COM (Common): This is the common terminal of the relay.
- CK (Normally Open - NO): This terminal is disconnected from COM when the relay is de-energized (before delay) and connected to COM when the relay is energized (after delay).
- CB (Normally Closed - NC): This terminal is connected to COM when the relay is de-energized (before delay) and disconnected from COM when the relay is energized (after delay).
Connect your load circuit to the appropriate relay terminals based on whether you need the load to be ON or OFF during the delay period.
5.3 Delay Time Adjustment
The delay time is adjustable using the onboard potentiometer. Turn the potentiometer to increase or decrease the delay duration. The delay time can be adjusted from 0 to 10 seconds.
The delay time (T) can be calculated using the formula: T = 1.1RC, where R is the resistance of the potentiometer and C is the capacitance of the timing capacitor (C1). Increasing the resistance of the potentiometer or the capacitance of C1 will increase the delay time.
6. Operation
Upon applying power (5V or 12V) to the VCC and GND terminals:
- The power indicator LED will illuminate.
- The relay will initially be in its de-energized state: COM is disconnected from CK (NO) and connected to CB (NC).
- The module will begin counting the set delay time (0-10 seconds), which is adjustable via the potentiometer.
- Once the delay time has elapsed, the relay will energize (pull in). The relay status indicator LED will illuminate.
- In the energized state: COM is connected to CK (NO) and disconnected from CB (NC).
- This energized state will be maintained as long as power is supplied to the module. To reset the timer, power must be removed and then reapplied.
7. Troubleshooting
- Module not powering on: Check power connections (VCC and GND) for correct polarity and voltage. Ensure the power supply is providing the correct voltage (5V or 12V) for your module variant.
- Relay not activating after delay: Verify the potentiometer setting. If the delay is set to minimum, it might activate almost instantly. Check the load connections and ensure they are within the relay's specified limits.
- Delay time is too short/long: Adjust the potentiometer. For significantly longer delays beyond the 0-10 second range, you may need to replace the timing capacitor (C1) with a higher value.
- Incorrect relay state: Double-check your load wiring to the COM, CK (NO), and CB (NC) terminals to ensure you are using the correct contact for your desired operation.
8. User Tips
- Simple Wiring: For basic power and load control, simply connect positive to VCC and negative to GND. The relay output terminals (COM, CK, CB) function like a standard switch.
- Extended Delay: If the maximum 10-second delay is insufficient, you can increase the value of the capacitor C1 on the board. This will extend the maximum achievable delay time.
- Inrush Current Protection: This module is ideal for applications where devices need to power on sequentially or with a delay to prevent high inrush currents, such as in car audio systems or multiple power-hungry appliances.