ZHURUI EM20/ER

Contents

ZHURUI EM20/ER Energy Meter User Manual

Model: EM20/ER

1. Introduction

Thank you for choosing the ZHURUI EM20/ER Energy Monitor. This device features a 2.8-inch TFT color LCD screen, designed to monitor various electrical parameters such as power, power factor, voltage, current, frequency, cumulative electricity consumption, cumulative electricity usage time, and electricity cost for electrical appliances. It records daily electricity consumption and cost in real-time, allowing historical data to be viewed in charts or lists. The EM20 Energy Monitor is suitable for use in households, factories, and offices, and can control the power supply at a set time (for the external relay version).

Main Features:

  • Fully digital operation and control.
  • 2.8-inch TFT color LCD display.
  • 0.5-class measurement accuracy.
  • Six touch buttons for easy navigation.
  • Date display and time setting.
  • Configurable automatic power-on, power-off, or retention of the last working state after power-off (Note: This feature is only supported by the external relay version).
  • Electricity consumption statistics are divided into cumulative and current consumption. Current consumption can be cleared with one key for specific measurement needs.
  • Four main display pages: Overview, Cumulative Electricity Consumption, Current Electricity Consumption, and Real-time Electrical Parameter. Switch between pages using the 'left' and 'right' keys.
  • Automatic recording of historical electricity consumption data, viewable as lists or charts, with data storage for up to 30 years.
  • Adjustable electricity rate with up to 4 decimal places, supporting Simple Mode, Time-of-Use Mode (8 period segmented charging), and Step-rate Mode (8 step progressive rates).
  • Nine groups of timers: Two advanced timers for specific dates/times (daily, weekdays, weekends) and seven general timers for specific time periods. (Note: This feature is only supported by the external relay version).
  • Alarm function for voltage, current, and power exceeding set values.
  • Output protection function to automatically cut off power supply when voltage, current, or power exceed set values, with automatic recovery option. (Note: This feature is only supported by the external relay version).
  • Energy-saving setting: screen can automatically turn off after 1, 5, or 10 minutes of inactivity, or remain always on. Measurement continues when the screen is off.
  • Functions for clearing cumulative electricity consumption, historical records, and restoring factory settings.

2. Packing List

Please check the contents of your package:

  • EM20 Energy Monitor Host: 1 unit
  • Current Transformer: 1 piece
  • User Manual: 1 copy
  • Warranty Card: 1 copy
  • Product Certificate: 1 piece

3. Safety Warnings

DANGER: If the device malfunctions, do not open the machine or replace parts by yourself to avoid electric shock. There are no replaceable parts inside the machine. In case of malfunction, please contact the manufacturer or authorized distributor.

  • Always cut off power during the installation process. Live operation is strictly prohibited to avoid electric shock.
  • The monitor is not designed for high-temperature and high-humidity environments. Please use it within the specified normal temperature and humidity range.
  • Ensure the working voltage range of the monitor is maintained between AC 85V and AC 265V.
  • The working current should not exceed the maximum current supported by the transformer.
  • The current transformer must not be open-circuited. An open-circuited transformer will output high voltage, which can cause safety problems.
  • Avoid exposing the monitor to environments with excessive dust, corrosive gases, or other harmful substances during storage and use.

4. Specifications

Product Classification and Model:

EM20: Standard Energy Monitor (no external relay)

EM20-ER: Energy Monitor with external relay

General Specifications:

  • Dimensions: 86mm x 86mm x 36.5mm
  • Operating Temperature: 0~40℃
  • Rated Voltage: 220V
  • Output Voltage: AC85~265V
  • Power Supply: AC
  • Accuracy Class: 0.5FS
  • Measuring Energy Range: 0~999999kWh
  • Phase: Single phase
  • Max Operating Current: 100A - 119A (Supports 120A Current Transformer max.)
  • Working Frequency: 50~60Hz
  • Display Type: LCD
  • Certification: CE
  • Power Consumption: <2W
  • Humidity: ≤ 90% RH

Latching Relay Driving Parameters (EM20-ER only):

  • Minimum Driving Voltage: 10 V
  • Maximum Driving Voltage: 15 V
  • Maximum Driving Current: 200 mA
  • Supported Latching Relay Coil Type: Single Coil

Timing Indicators:

  • Timing range: 999 days 23 hours 59 minutes
  • Timing resolution: 1 minute

Electrical Measurement Indicators:

ParameterMeasurement RangeResolution
VoltageAC 85~265 V0.1 V
Power (40A Transformer)0.5 W~10 kW0.1 W
Current (40A Transformer)0.01~40 A0.001 A
Power (60A Transformer)0.5 W~15 kW0.1 W
Current (60A Transformer)0.01~60 A0.001 A
Power (80A Transformer)1 W~20 kW0.1 W
Current (80A Transformer)0.02~80 A0.001 A
Power (100A Transformer)1 W~25 kW0.1 W
Current (100A Transformer)0.02~100 A0.001 A
Power (120A Transformer)1 W~30 kW0.1 W

Supported Currency Units:

Currency NameCurrency Symbol
CNY元
TWD圆
USD$
EUR€
GBP£
JPY¥
RUBруб
INRRs.
KRW원
TRY₺
THB฿
PHP₱
IDRRp
MYRRM
ZARR
AEDد.إ
SARر.س
ILS₪
CHFFr
DKKkr
UAH₴
BRLR$

Supported Transformer Types:

Ratio40A60A80A100A120A
1000:1√√√√X
2000:1√√√√√

5. Setup and Installation

The EM20/ER Energy Meter is designed for 86-type standard switch installation. Ensure power is off before installation.

Wiring Instructions:

Refer to the diagrams and video below for proper wiring. Incorrect wiring can lead to improper display of current and power values or safety hazards.

Rear view of EM20-ER Energy Monitor with wiring terminals and product label.
Rear view of EM20-ER Energy Monitor with wiring terminals and product label. Terminals are labeled CT1, CT2, N, L, 1, 2, 3, 4. Product label shows Model: EM20-ER, Product Name: Energy Monitor, Accuracy: 0.5FS, Power Consumption: <2W, Working Voltage: AC85V~265V, Support 120A Current Transformer max.
Close-up of EM20-ER Energy Monitor back with wiring terminals.
Close-up of EM20-ER Energy Monitor back with wiring terminals (CT1, CT2, N, L, 1, 2, 3, 4) and product label.
EM20 external relay version wiring diagram showing connections for magnetic latching relay and current transformer.
EM20 External Relay Version Wiring Diagram: This diagram illustrates the connections for the magnetic latching relay and current transformer. Pins 5 and 6 of the EM20 are connected to the relay. If the relay is disconnected when it should be energized or vice versa, swap the wiring of pins 5 and 6. For total current not exceeding 200mA, two latching relays can be connected in parallel to control live and neutral wires.
EM20 standard wiring diagram showing connections for current transformer.
EM20 Standard Wiring Diagram: This diagram shows the connections for the current transformer. The current transformer is connected to the main circuit to measure current.

Installation Video Guide:

Video demonstrating the installation process of the EM20 Energy Meter, including connecting the current transformer and power supply, and mounting the unit.

Key Steps from Video:

  1. Step 1: Wiring the Current Transformer (CT)
    • Pull down the main switch to cut off power.
    • Remove the live (fire) or neutral (zero) wire from under the switch.
    • Pass the removed wire through the current transformer.
    • Reconnect the wire to the main switch and tighten the screws.
    • Important: The live wire and neutral wire cannot both be covered by the current transformer, otherwise the current and power display will be incorrect.
  2. Step 2: Connecting the Meter's Power Supply and CT Output
    • Remove the back cover of the EM20 meter.
    • Connect pins 3 and 4 to the 220V AC power supply. There is no specific requirement for which pin connects to live or neutral.
    • Connect pins 1 and 2 to the two output lines of the current transformer. There is no specific requirement for the wiring order.
    • Secure the back cover to the button box of the switch using two screws.
    • Plug in the front panel cable. Ensure the direction of the wire is not reversed.

6. Operating Instructions

Main Working Pages:

The EM20/ER Energy Meter features four main display pages. The Overview Page is displayed by default after startup. Use the 'left' (<) or 'right' (>) keys to switch between the following pages:

  • Page 1: Overview Page - Shows real-time voltage, current, power, power factor, total kWh, cost, and duration, along with one-shot kWh, cost, and duration.
  • Page 2: Cumulative Electricity Consumption Page - Displays total cumulative kWh, voltage, and power.
  • Page 3: Current Electricity Consumption Page - Shows one-shot kWh, voltage, and power.
  • Page 4: Real-time Electrical Parameter Page - Displays real-time power, voltage, current, power factor, and frequency.

Status Bar Icons:

  • ■ Alarm icon: This icon flashes when an alarm event occurs.
  • ■ Timer icon: This icon is displayed in the status bar when the timer is turned on.
  • ■ Output off icon: This icon is displayed in the status bar when the socket output is turned off.
  • ■ Output on icon: This icon is displayed in the status bar when the socket output is turned on.

Button Description:

Button NameMain Page FunctionSetting Page Function
Menu Key (top-left)Press to display the system menu.Confirm the current input option.
Left Arrow Key (<)Switch main pages.Jump to the previous setting item.
Right Arrow Key (>)Switch main pages.Jump to the next setting item.
Up Arrow Key (△)Long press to turn on or off the output of the external relay.Increase the value of the setting item.
Down Arrow Key (▽)Long press to display the machine serial number.Decrease the value of the setting item.
Return Key (↶)Long press to clear current electricity consumption, cost, and usage time.Exit the setting page without saving current changes.

Viewing Historical Records:

  1. Press the Menu key (top-left) in the working state to pop up the system menu.
  2. Press the Down Arrow key (▽) to select "Historical Records". The item will be displayed with a blue background and white text.
  3. Press the Menu key (top-left) or Up Arrow key (△) to pop up the historical records sub-menu.
  4. Press the Up Arrow key (△) or Down Arrow key (▽) to select "Monthly Chart", "Monthly List", "Annual Chart" or "Annual List".
  5. Press the Menu key (top-left) to enter the historical records viewing page.

Function Settings:

To access the settings, long press the Up Arrow key (△) or Down Arrow key (▽) during the setting process for quick adjustment.

Process of Entering the Setting Page:

  1. Press the Menu key (top-left) in the working state to pop up the system menu.
  2. Press the Down Arrow key (▽) to select the desired menu item. The selected item will be displayed with a blue background and white text.
  3. If there is a sub-menu, press the Menu key (top-left) to pop up the sub-menu, then select the sub-menu item and press the Menu key (top-left) or Up Arrow key (△). If there is no sub-menu, press the Menu key (top-left) directly to enter the setting page.
  4. Press the Return key (↶) to exit the system menu.

Available Settings:

  • Language Setting: Choose between Chinese and English.
  • Currency Unit Setting: Select from various currencies (CNY, TWD, USD, EUR, GBP, JPY, RUB, INR, KRW, TRY, THB, PHP, IDR, MYR, ZAR, AED, SAR, ILS, CHF, DKK, UAH, BRL).
  • Electricity Cost Setting: Configure tariff settings, including Simple, Time-sharing, and Step-rate modes.
  • Date Format: Set the display format for dates (e.g., YYYY-MM-DD).
  • Time Setting: Adjust the current date and time.
  • Timer Setting: Configure up to 9 timers for automatic power on/off.
  • Switch Setting: Define the power state after startup (On, Off, or Same as last time).
  • Alarm Setting: Set thresholds for voltage, current, and power alarms.
  • Output Protection: Configure voltage, current, and power protection limits, and enable/disable auto-recovery.
  • Screen Setting: Adjust screen auto-off time (1, 5, 10 minutes) or keep it always on.
  • System Setting: Includes options for Measurement Adjust, Clear Total Energy, Clear History, and Factory Restore.
  • Range and CT Setting: Enable AutoRange, set CT Ratio (1000:1 or 2000:1), and Max Current (40A, 60A, 80A, 100A, 120A).
  • Measurement Result Adjustment: For fine-tuning measurement accuracy.

Note: All items in the system setting require a password to enter. The default password is "2010".

7. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the monitor to extreme temperatures, high humidity, or corrosive environments.
  • Do not attempt to open the device or perform any repairs yourself. Refer to qualified personnel or the manufacturer for service.
  • Ensure all wiring connections remain secure and free from damage.

8. Troubleshooting

Problem PhenomenonSolutionsRemarks
The icon ■ is displayed in the lower right corner of the screen when powered on, the icon ■ is displayed in the lower right corner of the screen when powered off.The pins of the latching relay are connected in reverse. Please swap the wiring of pins 5 and 6.Only for the external relay version
The device is not powered on after startup, and the ■ is displayed in the lower right corner of the screen.Long press the Up Arrow key (△) for three seconds to turn on the power supply, or enter the "Switch Setting" page and set the switch state to "Power-on". The monitor will automatically turn on the power supply to supply power to the device when it is turned on next time.Only for the external relay version
The device power supply is disconnected during operation, and the icon ■ is displayed, or the icon flashes.The monitor has entered the output protection state. Check whether the voltage, current, and power exceed the output protection set values. If necessary, the corresponding output protection set values can be changed, the corresponding output protection settings can be canceled, or the "Allow Startup Overload" checkbox can be checked.Only for the external relay version
The recorder beeps during operation, the icon ■ in the lower right corner of the screen flashes.The monitor has entered the alarm state. Check whether the voltage, current, and power exceed the alarm set values. If necessary, the corresponding alarm set values can be changed or the corresponding alarm settings can be canceled.

9. User Tips

  • Split-Phase Systems (e.g., USA): This meter is primarily designed for single-phase systems. If you are in a region with split-phase electricity (like the United States), a single EM20/ER unit with one current transformer will likely not provide accurate readings for your entire home. You may need to purchase two units, one for each leg of your split-phase supply, or ensure it's only used on a single-phase circuit.
  • Smart Features/Wi-Fi: The EM20/ER is a local display energy monitor and does not inherently support smart features or Wi-Fi connectivity for remote monitoring.
  • Bidirectional Metering (Solar Panels): The manual describes measuring cumulative electricity consumption and cost. It does not explicitly state support for bidirectional metering, which is required to accurately track energy fed back into the grid from sources like solar panels. If you need to monitor both consumption and generation, verify compatibility or consider a different model.

10. Warranty and Support

Your product package includes a Warranty Card. Please retain it for future reference.

Copyright © 2020 Shenzhen Zhurui Technology Co., Ltd. All rights reserved.

Without the written consent of Shenzhen Zhurui Technology Co., Ltd., no unit or individual may arbitrarily excerpt or copy part or all of this manual, and may not disseminate it in any form. The products described in this manual may contain hardware and software with copyrights owned by Shenzhen Zhurui Technology Co., Ltd. and its possible licensors. Unless obtained the written permission of the relevant right holders, no one may copy, distribute, lease, transfer or commit other infringing acts on the aforementioned hardware and software in any form.

Within the scope permitted by relevant laws, Shenzhen Zhurui Technology Co., Ltd. may modify the content of this manual under any circumstances.

Get More Information:

For additional support or inquiries, you may contact:

A detailed user manual in PDF format is also available for download: Download PDF User Manual

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.