The Hi-Link 3W ultra-small series module power supply is a compact, high-efficiency AC DC power module designed by Shenzhen Hi-Link Electronic Co., Ltd. It features a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. These modules are widely used in smart home, automation control, communications equipment, instrumentation, and other industrial applications.
Demonstration of the Hi-Link 3W Ultra-small series AC DC power supply module, showcasing its compact size and components.
Top view of the Hi-Link 3W AC DC power supply module.Bottom view of the Hi-Link 3W AC DC power supply module, showing PCB layout.Combined view of the top and bottom of the Hi-Link 3W AC DC power supply module.
2. Product Features
Ultra-thin, ultra-small, smallest volume.
Global universal input voltage (85~265Vac).
Low power consumption, green environmental protection, no-load loss < 0.1W.
Low ripple, low noise.
High output short circuit and over-current protection with self-recovery.
High efficiency, high power density.
Input and output isolation voltage 3000Vac.
100% full load aging and testing.
High reliability, long life design, continuous working time > 100,000 hours.
Meets UL, CE requirements; product design meets EMC and safety testing requirements.
Uses high-quality environmentally friendly waterproof plastic potting, resistant to moisture, vibration, water, and dust (IP65 standards).
Economic solutions, cost-effective.
Works without external circuit.
1-year quality guarantee period.
Diagram illustrating various applications for Hi-Link power modules, including charging stations, industrial control, solar energy, IoT, transportation, and medical devices.
3. Specifications
3.1. General Model Specifications
MODEL
Size (mm)
Output Power (W)
Output Voltage (V)
Output Current (mA)
HLK-PM03L
31.8*18*19
3
3.3
1000
HLK-PM01L
3
5
600
HLK-PM09L
3
9
330
HLK-PM12L
3
12
250
HLK-PM15L
3
15
200
HLK-PM24L
3
24
125
3.2. Environmental Conditions
Item
Technical Parameters
Units
Working temperature
-25 ~ +60
°C
Storage temperature
-40 ~ +80
°C
Relative humidity
5 ~ 95
%
Thermal methods
Natural cooling
Atmospheric pressure
80 ~ 106
Kpa
Altitude
≤2000
m
Vibration
10~500Hz, 2G10min./1cycle, 60min. each along X,Y,Z axes
Graph showing working environment temperature and load characteristics for the power module.
3.3. Input Features
Item
Technical Parameters
Units
Rated input voltage
100-240
Vac
Input voltage range
85-265
Vac
Maximum input current
≤0.1
A
Input inrush current
≤10
A
Input low start
≤50
mS
Long-term reliability
MTBF≥100,000
h
External fuse recommended
1A / 250Vac or 10Ω wire wound resistance
3.4. Output Features (HLK-PM03L - 3.3V/1000mA)
Item
Technical Parameters
Units
No-load rated output voltage
3.3±0.1
Vdc
Full-load rated output voltage
3.3±0.2
Vdc
Short time maximum output current
≥1100
mA
Rated output current
1000
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥72
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥72
%
Output ripple and noise (mVp-p)
≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load)≤ 5
%Vo
Output over-current protection
Output maximum load 110-150%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.5. Output Features (HLK-PM01L - 5V/600mA)
Item
Technical Parameters
Units
No-load rated output voltage
5.0±0.1
Vdc
Full-load rated output voltage
5.0±0.2
Vdc
Short time maximum output current
≥700
mA
Rated output current
600
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥73
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥73
%
Output ripple and noise (mVp-p)
≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load) ≤ 5
%Vo
Output over-current protection
Output maximum load 110-150%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.6. Output Features (HLK-PM09L - 9V/330mA)
Item
Technical Parameters
Units
No-load rated output voltage
9.0±0.1
Vdc
Full-load rated output voltage
9.0±0.2
Vdc
Short time maximum output current
≥430
mA
Rated output current
330
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥73
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥73
%
Output ripple and noise (mVp-p)
≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load)≤ 5
%Vo
Output over-current protection
Output maximum load 110-150%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.7. Output Features (HLK-PM12L - 12V/250mA)
Item
Technical Parameters
Units
No-load rated output voltage
12.0±0.1
Vdc
Full-load rated output voltage
12.0±0.2
Vdc
Short time maximum output current
≥350
mA
Rated output current
250
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥73
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥73
%
Output ripple and noise (mVp-p)
≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load) ≤ 5
%Vo
Output over-current protection
Output maximum load 110-150%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.8. Output Features (HLK-PM15L - 15V/200mA)
Item
Technical Parameters
Units
No-load rated output voltage
15±0.1
Vdc
Full-load rated output voltage
15±0.2
Vdc
Short time maximum output current
≥300
mA
Rated output current
200
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥73
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥73
%
Output ripple and noise (mVp-p)
≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load) ≤ 5
%Vo
Output over-current protection
Output maximum load 110-130%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.9. Output Features (HLK-PM24L - 24V/125mA)
Item
Technical Parameters
Units
No-load rated output voltage
24.0±0.1
Vdc
Full-load rated output voltage
24.0±0.1
Vdc
Short time maximum output current
≥220
mA
Rated output current
125
mA
Voltage regulation
±0.2
%
Load regulation
±0.5
%
Input low voltage efficiency
Vin=115Vac, Output full load ≥73
%
Input high voltage efficiency
Vin=230Vac, Output full load ≥73
%
Output ripple and noise (mVp-p)
≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)
mV
Switching on/off overshoot amplitude
(Rated input voltage, output plus 10% load) ≤ 5
%Vo
Output over-current protection
Output maximum load 110-130%
A
Output short circuit protection
Direct short circuit in normal output and automatic return to normal operation after removal of short circuit
3.10. Dimensions and Weight
Dimensional drawing of the power module with measurements in millimeters. Unit: mm. Error difference: +/-8%.Pin function diagram and dimensions for the power module. Weight: 9±2g.
4. Setup and Installation
4.1. Typical Application Circuit
Typical application circuit diagram for the AC DC power module.
4.2. Input Parts and Recommended Devices
Component Number / Recommended Device
Functions
Recommended Value
F1 / Fuse
Protect the circuit from damage when the module is working wrong
1A/250Vac, Slow fuse
MOV1 / Varistor
The cumulative surge is to protect the module from damage
10D561K
C1 / X Safety capacitance
Filtering, safety protection (EMC certification)
0.1uF/275Vac
L1 / Common-mode inductance
EMI filtering
Sensible value: 10-30mH Test requirements: 1KHZ / 0.3V current: 100-500mA
Notes:
Fuse and varistor are basic protective circuits (must be connected).
If you need to pass authentication/certification, the Safety capacitance and common-mode inductance cannot be omitted.
4.3. Output Parts and Recommended Devices
Component Number / Recommended Device
Functions
Recommended Value
C2 / Filter capacitor
Output ripple can be controlled in 30mV after adding this capacitor
Aluminium electrolytic capacitance, capacity 100-220 UF, voltage reduction greater than 75%
RL / Load
Load
Input voltage and load characteristics curve for AC input.Input voltage and load characteristics curve for DC input.
5. Operating Instructions
These power modules are designed for integration into electronic circuits. Ensure correct input voltage and load connections as per the application circuit diagram and specifications. The module operates automatically once power is supplied within the specified range.
6. Maintenance
These modules are designed for long-term reliability and generally require no specific maintenance. Ensure the operating environment adheres to the specified temperature and humidity ranges to prevent damage. Keep the module free from dust and moisture.
7. Troubleshooting
If the module is not functioning as expected, verify the input voltage is within the 85-265Vac range. Check all connections for proper polarity and secure contact. Ensure the load does not exceed the rated output current. If an external fuse is used, check if it is blown. For persistent issues, consult the technical support contact information.
8. User Tips
The wattage output varies by model, ranging from 2W to 40W depending on the specific HLK-PMxxL variant. Refer to the 'General Model Specifications' table in the specifications section for details.
9. Safety Information
9.1. Certification
Product design meets UL and CE safety certification requirements. Note that UL and CE certifications are made by the customer and need to be designed according to the reference circuit.
9.2. Safety and Electromagnetic Compatibility
The input design adopts UL listed 1A fuse.
The PCB board is made of double-sided copper clad foil, and the material fire resistance grade is 94-V0.
Safety standard meets UL1012, EN60950, UL60950.
Insulation voltage I/P-O/P: 2500Vac.
Insulation resistance I/P-O/P > 100M Ohms/500Vdc at 25°C 70% RH.
Conduction and radiation meet EN55011, EN55022 (CISPR22).