TOMZN DDS238-2 ZN/S

Contents

TOMZN DDS238-2 ZN/S Single Phase Energy Meter User Manual

Model: DDS238-2 ZN/S | Brand: TOMZN

1. Safety Information

Warning: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or play pens. This bag is not a toy.

This device complies with CE standards. Please dispose of packaging materials responsibly according to local recycling guidelines.

CE and recycling symbols

CE certification and recycling information.

2. Product Overview

The TOMZN DDS238-2 ZN/S is a single-phase multi-function DIN rail KWH Watt-hour energy meter with RS485 MODBUS-RTU communication. This device is designed to accurately measure and record electrical energy in a circuit.

TOMZN DDS238-2 ZN/S Energy Meter

The DDS238-2 ZN/S energy meter with its split CT.

Key Features:

  • Blue backlight LCD display for clear data visibility.
  • Real-time display of Voltage (V), Current (A), Active Power (W), Reactive Power (Var), Power Factor (COS), and Frequency (Hz).
  • Measures Total Energy (KWh), Positive KWh, and Reverse KWh (non-resettable).
  • Allows resetting of 'Rest Energy' KWh.
  • Equipped with a high-quality smart chip for reliable and precise measurements with minimal error.
  • RS485 communication interface for remote meter reading and programming using MODBUS-RTU protocol.
  • Compact design for 35mm DIN rail installation, saving space.
  • Thermoset housing for high-temperature resistance.
Smart chip inside the energy meter

Internal smart chip ensures high precision and long life.

3. Specifications

Product information and dimensions diagram

Detailed product information and dimensions.

ParameterValue
StandardIEC 62053-21 (IEC61036)
Nominal Voltage220-230V
Basic Current (Ib2)10A
Maximum Current100A
Minimum Current0.04A
Frequency50-60Hz
Consumption<0.8W/8VA
Accuracy Class1
Display TypeDigital Only (LCD 5+1 DIGITS)
Measuring Energy Range99999.9 KWh
PhaseSingle-phase
Power SupplyAC
Operating TemperatureNormal
Interface (Open Collector Output)1000imp/kWh (1.0Wh/imp) - 100A, 2000imp/kWh (0.5Wh/imp) - 65A
Mount35mm Din Rail
Dimensions (L*W*H)65mm * 35mm * 100mm
Starting Working Current20mA
CertificationCE, ROHS

4. Installation and Setup

  1. Professional Installation: After receiving the product, it is highly recommended to have a qualified electrical professional perform the installation and operation to ensure safety and proper functionality.
  2. DIN Rail Mounting: The meter is designed for easy installation on a standard 35mm DIN rail.
Energy meter mounted on a DIN rail

The meter is easily mounted on a 35mm DIN rail.

Wiring Diagram:

Connect the equipment in accordance with the following wiring diagram specifications. Ensure all connections are secure and correct before applying power.

Basic wiring diagram for the energy meter

Basic wiring for Line (L) and Neutral (N) connections, and the Current Transformer (CT).

Detailed wiring diagram with terminal labels

Detailed terminal connections including RS485, SO, and CT inputs.

Terminal Connections:

  • L & N: Main power input (220-230V).
  • CT+ & CT-: Current Transformer input. The split CT should be clamped around the 'L' (Line) wire of the circuit you wish to measure.
  • RS485A & RS485B: RS485 communication interface for remote meter reading and programming.
  • SO+ & SO-: Open Collector Output for pulse signals.

RS485 Remote Meter Reading:

Programming and meter reading operations can be completed via the RS485 communication interface using the 2007 Statute or MODBUS-RTU Statute protocols.

RS485 interface connection diagram

Connecting to the RS485 interface for remote data access.

5. Operating Instructions

Once installed and powered, the meter will display real-time electrical parameters on its LCD screen. Use the button on the front panel to cycle through different display modes and functions.

Display Modes:

The meter's carousel display provides real-time data for various parameters. Press the button to cycle through the following:

Carousel display showing various electrical parameters

The LCD cycles through various measurements including Total Energy, Import/Export Energy, Real Current, Active Power, Power Factor, Frequency, and more.

  • Total Energy (KWh): Cumulative energy consumption (cannot be reset).
  • Import Energy (KWh): Energy imported from the grid (cannot be reset).
  • Export Energy (KWh): Energy exported to the grid (cannot be reset).
  • Reset Energy (KWh): Temporary energy reading that can be reset to zero.
  • Real Current (A): Instantaneous current.
  • Active Power (W): Instantaneous active power.
  • Reactive Power (Var): Instantaneous reactive power.
  • Power Factor (COS): Power factor.
  • Real Frequency (Hz): System frequency.
  • Rest Time: Remaining time (if applicable).
  • Real Voltage (V): Instantaneous voltage.
  • Impulse Constant (imp/kWh): Pulse output constant.
  • MODBUS-RTU ID: Device ID for RS485 communication.
  • DL/T645 high 6 digit ID / DL/T645 low 6 digit ID: Device ID for DL/T645 protocol (if applicable).

Clearing Data:

To reset the 'Rest Energy' KWh reading:

Clear button and reset instruction

Press and hold the clear button for 10 seconds to reset the temporary KWh indicator.

Press and hold the button on the front panel for 10 seconds. The temporary KWh indicator will reset to zero.

Video Demonstration:

Demonstration of the meter's display cycling and button operation.

6. Precautions

  • Do not place the device near flammable materials.
  • Ensure adequate ventilation during operation to prevent overheating.
  • Disconnect the device from power and store it properly when not in use for extended periods.

7. Maintenance

The DDS238-2 ZN/S energy meter is designed for low maintenance. Keep the device clean and free from dust. Do not attempt to open or repair the device yourself, as this may void the warranty and pose a safety risk. For any issues, consult a qualified technician.

8. Troubleshooting

If you encounter issues with your energy meter, consider the following general troubleshooting steps:

  • No Display/Power: Check the power connections (L and N terminals) to ensure they are correctly wired and receiving power.
  • Incorrect Readings: Verify that the Current Transformer (CT) is correctly installed around the live wire and that its connections to the meter are secure. Ensure the CT is oriented correctly.
  • RS485 Communication Issues: Check the RS485A and RS485B wiring for correct polarity and secure connections. Ensure your communication software/device is configured with the correct MODBUS-RTU settings (baud rate, parity, stop bits, device ID).
  • Display Not Changing: Press the button to cycle through display modes. If the display is frozen, try power cycling the device (disconnect and reconnect power).

If problems persist, contact customer support or a qualified electrician.

9. User Tips

  • Inverter Compatibility: This meter is a single-phase energy meter with RS485 MODBUS-RTU communication. If you intend to use it with a solar inverter system (e.g., Growatt, ABB, Solax, Fronius), please verify that your inverter supports external energy meters via RS485 MODBUS-RTU and is compatible with single-phase measurement.
  • Current Transformer (CT) Included: The meter comes with a split Current Transformer (CT) for convenient installation.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's specific terms or contact the TOMZN customer service directly. Keep your purchase receipt for warranty claims.

11. Applicable Regulations and Harmonized Standards

This product complies with the following European Directives:

  • Low Voltage Directive 2014/35/EU
  • Electromagnetic Compatibility Directive 2014/30/EU
  • Restriction of the Use of Certain Hazardous Substances (RoHS) Directive 2011/65/EU