1. Introduction
This manual provides detailed instructions for the operation and maintenance of your Multi-function Transistor Tester. This device is designed for automatic detection and measurement of various electronic components, including transistors, diodes, resistors, capacitors, and more. Please read this manual thoroughly before using the device to ensure safe and correct operation.
2. Safety Information
- WARNING: Always be sure to DISCHARGE capacitors before connecting them to the tester! The tester may be damaged before you have switched it on!
- WARNING: We do not recommend using the tester to measure the battery! The battery voltage must be less than 4.5V, otherwise the tester may be damaged!
- WARNING: Charging input voltage up to 6V, do not exceed the top voltage, or it will damage the tester, and could cause the battery to explode!
- WARNING: Do not put the component into transistor test area, otherwise it is impossible to test zener diode!
- WARNING: Built-in Li-ion Battery, it is strictly prohibited to immerse the tester in water, or near a heat source!
- WARNING: For your personal safety, please strictly comply with the use of Li-ion Battery specifications and precautions!
- ATTENTION: Please do ESD protection!
- WARNING: Do not carry out other operations in the calibration process, so as not to affect the calibration accuracy!
3. Package Contents
Please check the package contents upon receipt. If any items are missing or damaged, please contact your vendor.
- 1 x Multi-function Transistor Tester (TC-T7-H, TCR-T7, LCR-TC1, or LCR-TC2 model)
- 3 x Test Hooks (Red, Green, Yellow)
- 1 x Micro USB Charging Cable
- Assorted test components (e.g., LED, capacitor, transistor, resistors)

The kit includes the main tester unit, three color-coded test hooks for easy connection, a USB cable for charging, and various electronic components for testing purposes.
4. Specifications
| Component | Range | Parameter Description |
|---|---|---|
| BJT | - | hFE(DC Current Gain), Ube(Base-Emitter Voltage), Ic(Collector Current), Iceo(Collector Cut-off Current (IB=0)), Ices(Collector short Current), Uf(Forward Voltage of protecting diode) |
| Diode | Forward Voltage <4.50V | Forward Voltage, Diode Capacitance, Ir(Reverse Current) |
| Double Diodes | Forward Voltage <4.50V | Forward Voltage |
| Zener Diode | 0.01-4.50V (Transistor test area) 0.01-20V (Zener Diode test area) | Forward Voltage, Reverse Voltage Reverse Voltage |
| JFET | - | Cg(Gate Capacitance), Id(Drain Current) at Vgs(Gate to Source Threshold Voltag), Uf(Forward Voltage of protecting diode) |
| MOSFET (IGBT) | - | Id(Drain Current) at Vgs(Gate to Source Threshold Voltag), Uf(Forward Voltage of protecting diode) |
| MOSFET | - | Vt(Gate to Source Threshold Voltag), Cg(Gate Capacitance), Rds(Drain to Source On Resistance), Uf(Forward Voltage of protecting diode) |
| Thyristor/Triac | Igt(Gate trigger current )<6mA | Gate trigger voltage |
| Capacitor | 25pF-100mF | Capacitance, ESR(Equivalent Series Resistance), Vloss |
| Resistor | 0.01-50MΩ | Resistance |
| Inductor | 0.01mH-20H | Inductance, DC Resistance |
| Battery | 0.1-4.5V | Voltage, Battery Polarity |
Display: TFT Graphic Display (160x128 pixels)
Power: Built-in Rechargeable Li-ion Battery (3.7V)
Dimensions: Approximately 9cm (L) x 7cm (W) x 2.6cm (H)

The tester measures approximately 9cm in length, 7cm in width, and 2.6cm in height, making it compact and portable.
5. Setup and Charging
5.1 Initial Charge
The tester is equipped with a built-in rechargeable Li-ion battery. Before first use, or if the battery voltage is low (tester will force shutdown if below 3.0V), please charge the device.
5.2 Charging the Battery
- Connect the provided Micro USB cable to the tester's Micro USB interface.
- Connect the other end of the USB cable to an external 5V USB power supply (e.g., phone charger, computer USB port).
- A red LED indicates that the device is charging.
- A green LED indicates that charging is complete.
WARNING: Charging input voltage should not exceed 6V. Exceeding this voltage will damage the tester and may cause the battery to explode.
6. Operating Instructions
6.1 Key Operational Definitions
The multi-function key has two primary actions:
- Short Press: Press the key for not less than 10 ms, then release within 1.5 seconds.
- Long Press: Press the key for more than 1.5 seconds.
6.2 Power On/Off
- Power On: In the power-off state, a short press of the multi-function key will turn on the tester and automatically initiate a measurement.
- Automatic Shutdown: The tester will automatically shut down after a component detection is completed, IR decoding is finished, or after reaching the set automatic shut-down time. The factory default is 20 seconds. Automatic shutdown time can be configured via hardware jumpers (10s, 15s, 20s, 25s).
- Manual Shutdown: A long press of the multi-function key will force a shutdown at any state, even if a measuring element is included.
6.3 Component Detection
The test seat is divided into a transistor test area and a Zener diode test area. Ensure the component is placed in the correct area.
- Ensure the tester is powered off or the previous test is complete.
- Carefully insert the component (e.g., transistor, diode, resistor) into the appropriate test area of the test seat.
- Press the locking handle to secure the component.
- Perform a short press on the multi-function key. The tester will automatically measure the component.
- Measurement results, including component type, pin layout, and parameters, will be graphically displayed on the TFT screen.
WARNING: Always discharge capacitors before connecting them to the tester to prevent damage.
Examples of Detected Components:
- Battery: Displays voltage (e.g., 3.72V).
- BJT (Bipolar Junction Transistor): Identifies NPN or PNP, displays hFE, Ube, Ic, Iceo, Ices.
- Diode: Displays forward voltage (Uf), capacitance (C), reverse current (Ir).
- MOSFET: Identifies N-E-MOS, P-E-MOS, N-MOS, P-MOS, displays Vt, Cg, Rds, Uf, Id.
- JFET: Identifies N-JFET, P-JFET, displays Cg, Id, Uf.
- IGBT: Identifies N-IGBT, P-IGBT, displays Cg, Id, Uf.
- Thyristor/Triac: Displays Uf.
- Capacitor: Displays capacitance (uF), Vloss, ESR.
- Resistor: Displays resistance (Ω).
- Inductor: Displays inductance (mH), DC resistance (R).
6.4 IR Decoder
The tester includes an IR decoder function, primarily supporting Hitachi IR format.
- After component detection is complete, point an infrared remote control at the tester's "IR" test hole.
- Press a key on the remote control.
- The tester will display the user code, data code, and the corresponding infrared waveform upon successful decoding.
- If decoding fails, the user code and data code will not be displayed.
- A dot at the top right corner indicates IR data reception (red for receiving, blue for successful decoding).
6.5 Self-Test and Calibration
Regular calibration ensures measurement accuracy.
- Initiate Self-Test: Short all three probes together.
- Perform a short press on the multi-function key. The tester will automatically begin the self-test process.
- During the calibration process, the tester may prompt to disconnect external wiring (isolate the probes). Follow the on-screen instructions.
- The self-test progress will be displayed (e.g., 5%, 22%, 100%).
- Once "Selftest End" is displayed, calibration is complete.
WARNING: Do not perform other operations during calibration to avoid affecting accuracy.
6.6 Built-in Li-ion Battery Voltage Measurement
The tester continuously monitors its internal Li-ion battery voltage. If the voltage drops below 3.0V, the device will automatically shut down, prompting you to charge the battery.
7. Maintenance
- Keep the device clean and dry. Use a soft, dry cloth to wipe the exterior.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Store the device in a safe place when not in use to prevent physical damage.
- Follow all battery charging warnings to ensure battery longevity and safety.
8. Troubleshooting (FAQ)
| Question | Cause | Solution |
|---|---|---|
| Cannot power on | Built-in Li-ion Battery is dead or discharged | Charge the Li-ion Battery (refer to section 5.2) |
| Inaccurate measurements | Inaccurate calibration parameters | Perform re-calibration (refer to section 6.5) |
| Tester shuts down unexpectedly | Battery voltage below 3.0V | Charge the Li-ion Battery immediately |
| IR decoder not working | Remote control not supported or decoding failure | Ensure remote uses Hitachi IR format; try different remote or check remote battery |
9. User Tips
- Always keep the test probes clean for reliable connections.
- When testing small components, ensure they are securely placed in the test socket to avoid intermittent readings.
- For best battery life, avoid fully discharging the device frequently.
10. Warranty and Support
This product is covered by a standard manufacturer's warranty. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer's customer service. Please retain your proof of purchase.