YIDI AD16-22 LED Indicator Light User Manual

Model: AD16-22

1. Introduction

Thank you for choosing the YIDI AD16-22 LED Indicator Light. This product is a versatile 22mm panel-mount LED signal lamp designed for various industrial and electrical applications. It features a built-in resistor and a non-polar LED, making it compatible with both AC and DC power sources across a wide voltage range. This manual provides essential information for safe installation, operation, and maintenance of your indicator light.

YIDI AD16-22 LED Indicator Lights in various colors

Figure 1: YIDI AD16-22 LED Indicator Lights (Red, Green, White, Blue, Yellow)

2. Package Contents

Please check the package for the following items:

  • 1 x AD16-22 LED Indicator Light
  • 1 x Washer
  • 1 x Nut
AD16-22 Indicator Light with washer and nut

Figure 2: Indicator Light Components

3. Setup and Installation

3.1 Mounting

  1. Ensure the power supply to the installation area is disconnected.
  2. Drill a 22mm diameter hole in your panel or enclosure.
  3. Insert the indicator light body through the drilled hole from the front.
  4. Place the washer over the threaded part of the indicator light from the rear of the panel.
  5. Thread and tighten the nut onto the indicator light from the rear of the panel to secure it firmly.
Dimensional drawing of AD16-22 indicator light

Figure 3: Dimensional Drawing (Unit: mm)

3.2 Wiring

The AD16-22 indicator light uses screw terminals for connection and features a non-polarity LED with a built-in resistor. This means there is no specific positive or negative terminal, simplifying wiring.

  1. Ensure the power supply is OFF before making any connections.
  2. Identify the two screw terminals (often marked X1 and X2) at the rear of the indicator light.
  3. Strip approximately 5-7mm of insulation from your power wires.
  4. Loosen the screws on the terminals.
  5. Insert one wire into each terminal and tighten the screws securely to ensure good electrical contact.
  6. Replace any protective caps if provided.
Rear view of AD16-22 showing screw terminals

Figure 4: Rear View with Screw Terminals (X1, X2)

Example of indicator light installed in a control panel

Figure 5: Example Installation

4. Operating Instructions

The YIDI AD16-22 LED Indicator Light operates by illuminating when power is supplied within its specified voltage range. Once properly installed and wired, simply apply the correct voltage to the terminals, and the LED will light up, providing visual indication.

5. Maintenance

  • Keep the indicator light clean by wiping it with a soft, dry cloth.
  • Avoid using abrasive cleaners or solvents, as these can damage the plastic lens.
  • Periodically check wiring connections to ensure they remain secure.

6. Troubleshooting

  • Light does not illuminate:
    • Check if the power supply is active.
    • Verify that the voltage supplied matches the indicator light's rated voltage.
    • Inspect wiring connections for looseness or incorrect wiring.
    • Ensure the indicator light itself is not damaged.
  • Light is dim:
    • Confirm that the supplied voltage is within the optimal operating range. Luminous intensity may be reduced with lower working currents.
    • Check for any voltage drops in the circuit.

7. Specifications

Feature Specification
Model Number AD16-22
LED Type B class no polarity LED lamp (AC/DC universal)
Rated Current 5-48V 15mA | 110-250V 2mA
Voltage Reduction Built-in resistor
LED Color Options Red, Green, Blue, White, Yellow (custom colors available)
LED Voltage (Operating Range) 12VDC (10.8-13.2V), 24VDC (21.6-26.4V), 110VAC (99-121V), 220VAC (207-253V)
LED Current (Typical) 20mA (for 12V/24V), 6mA (for 110V), 3mA (for 220V)
Max Reverse Voltage 5V
Viewing Angle 100°
Working Temperature -40°C to +85°C
Mounting Hole Diameter 22mm
Material ABS Plastic
Connecting Way Screw Terminal
Certifications CE, RoHS

8. User Tips

  • Easy Installation: Users have found this product easy to install and set up, performing as expected.
  • Verify Voltage: Always double-check the voltage rating of your indicator light and your power supply before connecting to prevent damage.
  • Secure Connections: Ensure all screw terminal connections are tight to prevent intermittent operation or electrical hazards.

9. Warranty and Support

For any questions, technical assistance, or warranty claims, please contact your seller or the manufacturer directly. Keep your purchase records for reference.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?