1. Introduction
Thank you for choosing the YIDI AD16-22SM Panel Mount LED Indicator Light Buzzer. This device combines a visual LED indicator with an audible buzzer, designed for various industrial and control panel applications. It features a 22mm mounting diameter and is available in multiple voltage options and LED colors. This manual provides essential information for safe installation, operation, and maintenance.

2. Safety Information
Please read and understand all safety instructions before installing or operating this device. Failure to do so may result in electric shock, fire, or personal injury.
- Always disconnect power before installation, maintenance, or troubleshooting.
- Ensure the voltage rating of the indicator light buzzer matches your power supply.
- Installation should be performed by qualified personnel in accordance with local electrical codes.
- Do not expose the device to excessive moisture or extreme temperatures outside its operating range (-40°C to +85°C).
- Avoid direct contact with live electrical components.
3. Package Contents
Each YIDI AD16-22SM package typically includes:
- 1 x AD16-22SM LED Indicator Light Buzzer
- 1 x Screw Nut for mounting
- 1 x O-ring for sealing

4. Specifications
| Feature | Detail |
|---|---|
| Model Number | AD16-22SM |
| Item Type | Indicator Lights (with Buzzer) |
| Brand Name | YIDI |
| Mounting Hole Diameter | 22mm |
| Head Diameter | 28mm |
| Total Length | 65mm |
| Material | Plastic |
| LED Type | B class no polarity LED lamp (AC/DC universal) |
| Rated Current (5-48V) | 15mA |
| Rated Current (110-250V) | 2mA |
| Power Source | AC |
| Voltage Options | 12V, 24V, 110V, 220V (also 2VDC, 28VDC, 48VDC available for specific models) |
| LED Colors | Red, Green, Yellow (customizable colors available) |
| Is Bulbs Included | Yes |
| Luminous Flux | <60 (varies by color and voltage) |
| Max Reverse Voltage | 5V |
| Viewing Angle | 100° (dependent on mode) |
| Working Temperature | -40°C to +85°C |
| Certification | CE, RoHS |
For detailed LED intensity values per color and voltage, please refer to the full product specifications document.

5. Setup and Installation
Follow these steps to properly install your AD16-22SM indicator light buzzer:
- Prepare Mounting Hole: Drill a 22mm diameter hole in your control panel or enclosure. Ensure the panel thickness is suitable for the device's threading.
- Insert Indicator: Insert the indicator light buzzer through the front of the panel into the drilled hole.
- Secure with O-ring and Nut: Place the O-ring over the threaded body from the rear of the panel, then thread and tighten the screw nut to secure the indicator firmly in place.
- Wiring:
- The AD16-22SM uses a B class no polarity LED, meaning there is no specific anode (+) or cathode (-) terminal for the LED function.
- It has an inner resistor, so no external resistor is needed for the specified voltages (12V, 24V, 110V, 220V).
- Connect your power supply wires to the two screw terminals at the rear of the device. Ensure connections are secure.
- For 2VDC applications, if your specific model does not explicitly state "No Resistor", an external resistor might be required. Always verify the voltage and current requirements for your specific variant.
- Test: Once installed and wired, apply power to test the indicator light and buzzer function.

6. Operating Instructions
The YIDI AD16-22SM functions as both a visual indicator and an audible alarm. When the rated voltage is applied to its terminals, the LED will illuminate, and the buzzer will sound. The buzzer typically produces a continuous or flashing sound, depending on the specific model variant.
The video below demonstrates the buzzer in operation:
7. Maintenance
The AD16-22SM indicator light buzzer is designed for low maintenance. To ensure optimal performance and longevity:
- Cleaning: Periodically clean the surface of the indicator light with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the plastic.
- Inspection: Regularly inspect the wiring connections to ensure they remain tight and free from corrosion.
- Environmental Conditions: Ensure the device operates within its specified temperature range and is protected from excessive dust or moisture.
8. Troubleshooting
If your AD16-22SM indicator light buzzer is not functioning as expected, consider the following:
| Problem | Possible Cause | Solution |
|---|---|---|
| LED does not light up / Buzzer does not sound | No power supply or incorrect voltage. | Verify power is applied and matches the device's rated voltage. Check circuit breaker/fuse. |
| Loose or incorrect wiring. | Check all wiring connections for tightness and correct polarity (though the LED is non-polar, ensure the circuit is complete). | |
| Device is faulty. | If power and wiring are confirmed correct, the device may be damaged. Replace if necessary. | |
| Buzzer sounds, but LED is dim or off | Lower than optimal working current. | Ensure the power supply can deliver the rated current (e.g., 20mA for 12V/24V/28VDC, 6mA for 110VAC, 3mA for 230VAC). Luminous intensity reduces with lower current. |
9. User Tips
- Voltage Selection: Always double-check the voltage rating of the specific indicator light buzzer you are using to prevent damage.
- Panel Thickness: When mounting, ensure your panel thickness allows for sufficient threading of the screw nut to secure the device properly.
- Environmental Protection: For outdoor or harsh environments, consider additional protection for the panel opening to enhance the device's lifespan.
10. Warranty and Support
For warranty information, technical support, or further inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format is available for download: YIDI AD16-22SM User Manual (PDF).