1. Product Overview
The DIANQI AD16 Series Mini Digital Panel Meter is a compact, high-precision measuring instrument designed to fit standard 22mm control panel cutouts. It provides real-time digital display of voltage, current, frequency, or other electrical parameters. This meter combines a robust plastic housing with advanced A/D conversion technology for stable and accurate readings in industrial environments.
Key Features:
- Compact Design: Fits standard 22mm mounting holes, saving panel space.
- High Visibility: Bright LED display for clear reading in various lighting conditions.
- Multi-Function: Available as DC/AC Voltmeter, Ammeter, Frequency Meter, or Dual-Display models.
- Wide Measurement Range: Supports various ranges (e.g., DC 0-100V, AC 0-500V, 0-10A).
- Easy Installation: Snap-in or nut-fix mounting with simple wiring.
- Durable Housing: Flame-retardant PC/ABS plastic case.
- Low Power Consumption: Efficient circuit design.
Applications:
Power distribution panels, battery monitoring systems, generator sets, solar power controllers, industrial machinery, and laboratory equipment.

2. Safety Warnings
WARNING: Disconnect all power sources before installation. High voltage can cause severe electric shock or death. Ensure the rated voltage of the meter matches your circuit. Failure to follow these instructions may result in injury or damage to the device.
3. Setup and Installation
Step 1: Panel Preparation
- Drill a precise hole of 22.2 mm in the control panel.
- Clean any burrs or sharp edges around the hole to ensure a smooth fit and prevent damage to the meter housing.
Step 2: Mounting
- Insert the meter into the hole from the front of the panel.
- Depending on the specific model:
- Nut-Fix Type: Slide the provided plastic locking nut onto the rear threads and tighten gently.
- Clip-Fix Type: Push the meter until the side retaining clips snap securely behind the panel.
- Torque Warning: Do not overtighten the locking nut (Max 1.5 N·m) as it may crack the plastic housing or distort the display window.
Step 3: Wiring
Note: Wiring varies significantly between Self-Powered (Voltmeters) and Auxiliary-Powered (Ammeters/Frequency) models. Refer to the label on the back of the unit for specific instructions.

A. DC/AC Voltmeter (Self-Powered):
- Typically has 2 wires/terminals.
- Connect directly across the voltage source to be measured.
- Polarity: For DC models, observe Positive (+) and Negative (-). Reverse connection may damage the unit or show negative values. AC models are non-polar.
B. DC Ammeter (with External Shunt):
- Requires an external shunt for currents >10A.
- Connect the shunt in series with the load.
- Connect the meter's signal wires to the signal terminals of the shunt (not the main power terminals).
- Warning: Never connect the ammeter directly across a power source; it will short-circuit and burn out.
C. AC Ammeter (Direct or CT):
- Direct (<5A): Connect in series with the load.
- CT (>5A): Connect to the secondary side of a Current Transformer (CT). Never open-circuit a CT secondary while energized.

Step 4: Verification
- Restore power.
- The display should light up immediately (for self-powered V models) or after auxiliary power is applied.
- Verify the reading against a calibrated reference meter.
4. Operating Instructions
Once properly installed and powered, the AD16 Series Mini Digital Panel Meter will display the measured electrical parameter (voltage, current, or frequency) on its bright LED screen. Readings are shown digitally for clear interpretation.
- Voltmeter: Displays voltage in Volts (V).
- Ammeter: Displays current in Amperes (A).
- Frequency Meter: Displays frequency in Hertz (Hz).
For dual-display models, both voltage and current will be shown simultaneously.
5. Specifications
| Parameter | Specification |
|---|---|
| Model Series | AD16-PM (Panel Meter) |
| Mounting Hole Diameter | 22 mm (+0.5/-0.0 mm) |
| Display Type | 3-Digit or 4-Digit LED (0.36"/0.56") |
| Display Color | Red (Standard), Green, Blue, Yellow (Optional) |
| Measurement Types | DCV (e.g., 0-200V), ACV (e.g., 0-500V), DCA (e.g., 0-10A), ACA (e.g., 0-5A direct), Hz (45-65Hz) |
| Accuracy Class | ±0.5% F.S. (Full Scale) ±1 Digit |
| Sampling Rate | Approx. 2-3 times/second |
| Rated Supply Voltage | Self-Powered (for V models) |
| Auxiliary Power | AC/DC 12V, 24V, 220V (for A/Hz models or specific versions) |
| Input Impedance | >1 MΩ (Voltage inputs) |
| Operating Temperature | -10°C to +50°C |
| Storage Temperature | -20°C to +70°C |
| Protection Rating | IP54 (Front Panel) |
| Housing Material | PC/ABS (Flame-retardant) |
| Terminal Type | Screw terminals or Wire Leads (150mm) |
| Dimensions (Overall) | Approx. 45mm (Height) x 29mm (Bezel) |
| Panel Thickness | 1mm - 5mm |
| Certification | CE |
| Battery Included | No |
6. Maintenance
Cleaning:
Wipe the display window with a soft, dry cloth. Do not use abrasive cleaners or solvents that may scratch or cloud the plastic lens.
Inspection:
Periodically check terminal tightness to prevent overheating due to loose connections.
Environment:
Ensure the meter is used within its specified temperature and humidity limits.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display blank | No power supply; Loose wiring; Burnt fuse/internal component. | Check input voltage. Verify wiring connections. Replace unit if internal fault. |
| Incorrect reading | Wrong range selected; Calibration drift; Interference. | Verify model range matches application. Check for nearby strong magnetic fields. |
| Flickering display | Unstable power supply; Loose connection; Voltage below minimum operating threshold. | Stabilize power source. Tighten terminals. Ensure voltage is within operating range (e.g., >20V for some models). |
| "----" or "OL" | Over-range input (Voltage/Current exceeds limit). | Disconnect immediately. Use a meter with a higher range or add a potential transformer/shunt. |
| Negative value (DC) | Polarity reversed. | Swap the positive and negative input wires. |
8. User Tips
- Visibility: The display may appear dim and visibility can be limited in bright daylight conditions.
- Voltage Compatibility: This device is designed for AC 60-500V operation and is not compatible with 12V DC power sources.
9. Warranty and Support
For warranty information and technical support, please contact your seller or refer to the product packaging. Keep your purchase receipt for any warranty claims.
Disclaimer:
This manual provides general guidelines for the AD16 Series Mini Digital Panel Meter. Specific wiring and ratings must be verified against the label printed on the actual product, as configurations vary by manufacturer and model. The manufacturer is not liable for any damage, injury, or loss resulting from improper selection, incorrect wiring, misuse, or operation beyond the specified ratings.
A PDF version of this manual may be available from the seller or product page for detailed reference.