1. Introduction
The PEAKMETER PM6252A and PM6252B are advanced digital anemometers designed for accurate measurement of wind speed and air volume. The PM6252B model also includes capabilities for measuring ambient temperature and relative humidity, and features a USB port for data connectivity. These devices are ideal for various applications requiring precise environmental data.

Figure 1: PEAKMETER PM6252A Digital Anemometer (front view)

Figure 2: PEAKMETER PM6252B Digital Anemometer (front view)
2. Safety & Warnings
Please read all instructions carefully before using the device to ensure safe operation and prevent damage.
- Always turn off the device when not in use.
- Do not expose the device to extreme temperatures, humidity, or direct sunlight.
- Keep the device and its cord out of reach of children under 3 years old.
- Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Ensure the battery compartment is securely closed during operation.
3. Setup and Battery Installation
3.1 Unpacking and Initial Inspection
- Carefully remove the anemometer from its packaging.
- Inspect the device for any signs of damage. If damaged, do not use and contact your supplier.
- Remove any protective films from the device, especially from the display and sensor areas.
3.2 Battery Installation
The device requires a 9V 6F22 battery (not included). Follow these steps to install the battery:
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open the compartment.
- Insert a new 9V 6F22 battery, ensuring correct polarity (+ and -).
- Close the battery compartment cover securely.

Figure 3: Battery compartment for 9V 6F22 battery
3.3 USB Connection (PM6252B only)
The PM6252B model features a USB port, primarily for data transfer to a computer. Connect the provided USB cable to the device and your computer. Ensure necessary drivers or software are installed on your computer for data logging or analysis.

Figure 4: PM6252B model with close-ups of components including the USB port
4. Operating Instructions
4.1 Power On/Off
- To Power On: Press and hold the Power button (
) for approximately 3 seconds. The LCD display will illuminate. - To Power Off: Press and hold the Power button again for 3 seconds.
- Auto Power Off: The device features an auto power-off function to conserve battery life. It will automatically shut down after a period of inactivity (typically 10-15 minutes).
4.2 Function Selection (FUNC Button)
Short press the FUNC button to cycle through different measurement modes, such as wind velocity (VEL) and air volume (FLOW AREA). For PM6252B, this may also include temperature and humidity displays.
4.3 Data Hold (HOLD Button)
Press the HOLD button to freeze the current reading on the display. Press it again to release the hold and resume live measurements.
4.4 Maximum/Minimum Measurement (MAX/MIN Button)
Press the MAX/MIN button to display the maximum or minimum recorded values during a measurement session. Pressing it repeatedly will cycle through MAX, MIN, and current readings.
4.5 Unit Selection (UNIT Button)
Press the UNIT button to change the units of measurement for wind speed (e.g., m/s, Ft/m, Km/h, Mile/h, Knots) or air volume (e.g., CFM, CMM, CMS).
4.6 Backlight (Light Bulb Button)
Press the Light Bulb button (
) to turn the display backlight on or off for improved visibility in low-light conditions.
5. Maintenance & Storage
5.1 Cleaning
- Turn off the device before cleaning.
- Use a soft, lint-free cloth to wipe the exterior of the device.
- Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing or display.
- Keep the fan blades free from dust and debris for accurate readings. Use a soft brush or compressed air if necessary.
5.2 Storage
- Store the device in a dry place at room temperature (15°C - 35°C).
- Avoid storing in areas with high humidity, extreme temperatures, or direct sunlight.
- For long-term storage (if not used for an extended period), remove the 9V battery to prevent leakage and potential damage to the device.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Low or dead battery; Incorrect battery installation | Replace the 9V battery; Check battery polarity. |
| Inaccurate readings | Obstructed fan; Sensor dirty; Environmental interference | Ensure fan is clear and spinning freely; Clean the sensor area; Move to a stable environment. |
| Display not working or dim | Low battery; Backlight off | Replace battery; Press the backlight button. |
| PM6252B USB connection not working | Incorrect cable; Driver issues; Software not installed | Ensure correct USB cable is used; Install necessary drivers/software; Try a different USB port. |
7. Specifications

Figure 5: Approximate dimensions of the anemometer
| Feature | Details (PM6252A) | Details (PM6252B) |
|---|---|---|
| Type | Anemometer | |
| Model Number | MS6252A/MS6252B | |
| Origin | Mainland China | |
| Certification | CE | |
| Power Supply | 9V 6F22 Battery (Not Included) | |
| Size | 165 x 85 x 38mm / 6.61 x 3.34 x 1.57 in. | |
| Weight | Approx. 200g | |
| Air Velocity Range | 0.40-30.0 m/s (80-5900 Ft/m, 1.4-108.0 Km/h, 0.9-67.0 Mile/h, 0.8-58.0 Knots) | |
| Air Velocity Accuracy | ±(2.0%+50) | |
| Air Temperature Range | - | -20 to 60°C |
| Air Temperature Accuracy | - | ±1.5°C (±2.7°F) |
| Air Relative Humidity Range | - | 0 to 100% RH |
| Air Relative Humidity Accuracy | - | ±3% |
| Air Flow (CFM) | 0 to 99990 (Area: 0 to 9.999 ft²) | |
| Air Flow (CMM) | 0 to 99990 (Area: 0 to 9.999 m²) | |
| Air Flow (CMS) | 0 to 9999 (Area: 0 to 9.999 m²) | |
| Flow Area Setting | Yes | Yes |
| MAX/MIN Function | Yes | Yes |
| Display Backlight | Yes | Yes |
| Auto Power Off | Yes | Yes |
| C/F Selection | - | Yes |
| Ambient, Dew point & wet bulb temperature | - | Yes |
| Low Battery Indication | Yes | Yes |
| USB Interface | - | Yes |
8. User Tips
- For the most accurate wind speed readings, ensure the anemometer's fan is facing directly into the airflow.
- Hold the device steady and avoid sudden movements during measurement.
- When measuring air volume, accurately input the duct or area dimensions into the device's settings for precise calculations.
- Keep the sensor clean, as dust or debris can affect measurement accuracy.
9. Frequently Asked Questions (FAQ)
- Q: What type of battery does this anemometer use?
- A: Both PM6252A and PM6252B models use a 9V 6F22 battery (not included).
- Q: How do I change the measurement units?
- A: Press the 'UNIT' button to cycle through available measurement units for wind speed or air volume.
- Q: Does the PM6252A model measure temperature and humidity?
- A: No, only the PM6252B model measures ambient temperature and relative humidity.
- Q: What is the USB port on the PM6252B used for?
- A: The USB port on the PM6252B is used for data transfer to a computer, allowing for data logging and analysis.
10. Disposal & Recycling
This symbol indicates that this product should not be treated as household waste. According to the WEEE Directive (2012/19/EU), it must be disposed of at an appropriate electronic waste collection point for recycling to prevent potential negative consequences for the environment and human health. Please contact your local authorities for information on proper disposal methods.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.
Further detailed instructions and specifications may be available in the official user manual PDF, which can be accessed via the seller's product page or by contacting support.