1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your HLTNC 1.5kW Air-Cooled Spindle Kit. The kit includes a 1.5kW square air-cooling spindle motor and a 1.5KW VFD inverter, along with ER11 collets. This system is designed for milling applications, offering ultra-high speed and reliable performance.

2. Safety Precautions
Before installation, operation, or maintenance, please read and understand all safety warnings and instructions. Failure to do so may result in serious injury or equipment damage.
2.1 General Safety Guidelines
- Ensure the machine is strictly packaged before leaving the factory. Inspect for any damage or deformation during transportation.
- Verify that the ordered specifications (working voltage, KVA number) match the nameplate.
- Check for any abnormal internal assembly parts, wiring, or circuit board issues.
- Ensure all terminals are tightly locked and free of foreign matter.
- Confirm that all buttons on the operator panel are functioning correctly.
- Verify that all additional accessories are present.
2.2 Electrical Safety
- Always ensure the power supply voltage is consistent with the inverter's voltage levels to prevent damage.
- Correctly connect the inverter's main circuit and control signal wires.
- Do not operate the inverter if the installation is not secure; place a flat plate under the base if necessary.
- The installation wall should be made of non-combustible materials (e.g., iron plates).
- When installing multiple inverters in the same cabinet, ensure proper spacing and use baffles between them.
3. Components Overview
The HLTNC 1.5kW Air-Cooled Spindle Kit typically includes the following main components:
- 1.5kW Air-Cooled Spindle Motor: Features 0-24000rpm ultra-high speed, four high-quality bearings, and high temperature resistance for silent operation.
- 1.5KW VFD Inverter: A Variable Frequency Drive (VFD) for controlling the spindle motor's speed and direction.
- ER11 Collets: A set of 7 ER11 collets for tool holding.
- Product Manual: This instruction manual.




4. Specifications
Below are the general specifications for the HLTNC 1.5kW Air-Cooled Spindle Kit:
| Attribute | Value |
|---|---|
| Brand Name | HLTNC |
| Model Number | 1.5kw Air Cooled Spindle |
| Certification | CE |
| Origin | Mainland China |
| Drive | Motor |
| Maximum Torque | 0.88Nm |
| Operating Speed | 24000 RPM |
| Application | Milling |
| Cooling | Air-cooled |
| Voltage Options | 110V/220V/380V |
| Collet Type | ER11 |
| Runout Off | Less than 0.005 |
| Inverter Brand | Huanyang (HY) / YL |
4.1 Product Model and Specification Table
| Model | Input Voltage | Power (KW) | Drive Capacity (KVA) | Output Current (A) | Applicable Motor (KW) |
|---|---|---|---|---|---|
| YL620/YL620-A | Single-phase 110V 60Hz | 0.75 | 4 | 7.8 | ≤0.75KW |
| YL620/YL620-A | Single-phase 110V 60Hz | 1.5 | 6 | 13 | ≤1.5KW |
| YL620/YL620-A | Single-phase 110V 60Hz | 2.2 | 8 | 21 | ≤2.2KW |
| YL620/YL620-A | Single-phase 220V 50/60Hz | 0.75 | 2.4 | 4 | ≤0.75KW |
| YL620/YL620-A | Single-phase 220V 50/60Hz | 1.5 | 3.0 | 7 | ≤1.5KW |
| YL620/YL620-A | Single-phase 220V 50/60Hz | 2.2 | 4.0 | 10 | ≤2.2KW |
5. Setup and Installation
Proper installation and wiring are crucial for the safe and correct operation of your spindle kit. Refer to the diagrams and instructions carefully.
5.1 Unboxing and Initial Inspection
Upon receiving your spindle kit, carefully unbox all components and inspect them for any visible damage. Ensure all parts listed in the components section are present.
5.2 Wiring Diagram and Terminal Descriptions
The following diagram illustrates the main circuit wiring between the VFD inverter and the spindle motor. Ensure all connections are secure and correct.

Main Circuit Terminal Description:
| Terminal Symbol | Description |
|---|---|
| N L | Power input terminal (220V inverter is single-phase 220V input, 110V inverter is single-phase 110V input) |
| U.V.W | Inverter output terminal (220V inverter is three-phase 220V output, 110V inverter is three-phase 110V output) |
| + DB- | Braking resistor connection end optional (refer to manual for configuration details) |
| FG | Frame Ground (Protecting Earthing) |
Control Terminal Description:
| Terminal Symbol | Description |
|---|---|
| NC | NOTCONNECTED |
| MO | Triode output |
| FWD | Forward |
| REV | Reverse |
| X1-X4 | Multi-function input 1-4 |
| XGND | Common terminal of digital control signal |
| XVCC | External input 15V |
| GND | Analog control signal common terminal |
| VI1 | Analog current frequency command |
| 10V | Power supply for speed setting |
| 13V | External power supply |
| AO | Analog output |
| NC1 | Relay normally closed contact |
| NO1 | Relay normally open contact |
| CM1 | Relay common terminal |
6. Operation
6.1 Digital Operator Panel Description
The VFD inverter features a digital operator panel for controlling and monitoring the spindle motor. Key elements include:
- Digital Display: Shows frequency, RPM, and other parameters.
- F/R Key: Forward/reverse switch key.
- RUN Key: Starts operation.
- STOP Key: Stops operation and resets.
- DISP Key: Shift key for navigating parameters.
- Arrow Keys (▲▼): Increase/decrease values or navigate menus.
- PRGM Key: Programming key (forward/backward).
- SET Key: Select/confirm key.
6.2 Parameter Setting Method
- Press the PRGM key until the inverter displays "Pyy.xx" to enter the parameter setting state. (yy = parameter group number, xx = parameter number).
- Use the ▲▼ keys to select the desired parameter group and number.
- Press the SET key to enter the parameter value setting state.
- Use the ▲▼ keys to modify the parameter value.
- Press the SET key again to save the modified parameter value.
- Press the PRGM key to exit the parameter setting state.
Important: Parameters should only be set when the inverter is stopped. If the parameter table is locked (P00.13=1), parameters can only be viewed, not modified.
6.3 Trial Run
Before initial operation, perform the following checks:
- Verify all wiring for errors, especially ensuring the power supply is connected to the N/L terminals, not U.V.W.
- Check for any metal chips or loose wires on the inverter substrate or wiring terminals that could cause short circuits.
- Ensure all screws are tightly locked and connectors are secure.
- Confirm there is no short circuit or ground fault in the output part.
After these checks, you can perform a trial run. Each time the STOP button is pressed, the cooling fan will run for about 30 seconds, allowing you to observe its operation.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your spindle kit.
- Cleaning: Regularly clean the spindle motor and inverter to prevent dust and debris buildup, which can affect cooling and performance. Use compressed air for hard-to-reach areas.
- Cooling System: Ensure the air-cooling fins on the spindle motor are clear and unobstructed. For the inverter, ensure adequate ventilation and check that the cooling fan is operating correctly.
- Connections: Periodically check all electrical connections for tightness. Loose connections can lead to intermittent operation or damage.
- Bearings: The spindle motor uses high-quality bearings. While generally maintenance-free, listen for unusual noises that might indicate bearing wear.
- Environment: Maintain the operating environment within specified temperature and humidity ranges to prolong the life of the inverter and spindle.
8. Troubleshooting
This section provides common fault information and troubleshooting methods. If an issue persists after attempting these solutions, contact technical support.
| Error Code/Fault | Phenomenon | Analysis and Solutions |
|---|---|---|
| Er.00 | Power failure, power supply voltage lower than 140VAC | Check input power voltage (150-250V range). If too high, it will damage the inverter. If large inertia load, deceleration time setting may be too small. |
| Er.01 | Power supply voltage higher than 290VAC, internal bus voltage too high | Inaccurate voltage detection (requires maintenance). If large inertia load, consider external braking resistor. |
| Er.02 | The current is too large | Check for motor short-circuit, correct connection, or excessive mechanical load. Otherwise, maintenance is required. |
| Er.03 | External PWM circuit error | Internal PWM circuit error. Turn off power for 1 minute, then retry. If it recurs, maintenance is required. |
| Er.04 | IPM alarm (short circuit) | Internal power unit module error, acceleration/deceleration time too short, overcurrent/overheated, motor short-circuited/excessive mechanical load, input voltage too high/low, inverter/motor mismatch, incorrect star/delta wiring, improper DC braking parameters (P01.09-P01.17), improper VF parameters (P00.04-P00.12), damaged/blocked cooling fan, or incorrect gate drive voltage. |
| Er.05 | External fault signal is input | Motor stops and displays code. Reset to clear. No maintenance required. |
| Er.06 | Internal data storage error | Error in internal data parameter storage. Turn off power for 1 minute, then test. |
| Er.07 | Over temperature | Inverter internal temperature too high (>65°C). Check cooling fan operation, motor short-circuit/load, heat conduction. |
| Er.08 | NTC temperature measurement error | Internal temperature detection circuit or sensor is defective. Requires repair. |
| Er.10 | Power down prompt | Check input power voltage is within range. |
| Er.11 | RS485 communication disconnected and error occurs, machine stops | Related to parameters P03.03, P03.04. |
| Er.12 | Parameter error | Check parameter settings for validity. |
| Er.15 | Motor overheated | Reduce load or check motor cooling. |
9. User Tips
- Mach3 Integration: If you plan to control the spindle speed using a CNC controller like RnRMotion via Mach3, ensure your VFD inverter is compatible and properly configured for external control. Refer to the VFD manual's sections on external control wiring and parameter settings (e.g., P00.01 for start/stop command source).
- Spindle Structure: The spindle motor has a square form factor, which is common for air-cooled CNC spindles.
- Application: This kit is suitable for various milling applications.
10. Warranty and Support
For any issues not covered in this manual or for technical assistance, please contact the manufacturer or your local dealer. Ensure you have your product model and serial number available when seeking support.
Due to ongoing product updates, the content of this manual is subject to change without prior notice.