1. Introduction
This manual provides detailed instructions for the installation, setup, and operation of the T2401-O DC 12V Dual Display Time Relay Module. This mini LED digital timer relay is designed for precise timing control in various applications, offering a wide timing range and multiple operating modes. Please read this manual thoroughly before use to ensure proper and safe operation.
2. Product Features
- Simplified parameter setting.
- Compact and exquisite appearance.
- Direct output type.
- Timing range: 0-999 (seconds, minutes, hours), with a minimum unit of 1 second.
- Convenient direct output wiring with clear indicators (green for start, red for stop).
3. Product Specifications
| Parameter | Value |
|---|---|
| Product Model | T2401-O |
| Product Weight | 30g |
| Product Size | 48mm x 29mm x 34mm |
| Mounting Opening | 45.5mm x 26.1mm |
| Timing Range | 0-999 (seconds, minutes, hours), minimum unit: 1 second |
| Supply Voltage | DC 12V |
| Max Current | 20A |
| Max Power | 240W |
| Working Humidity | 35%~85% |
| Working Temperature | -10~60°C |
| Type | Voltage Regulator |
| Application | Computer (general electronic control) |
4. Package Contents
- 1 x Digital Display Delay Relay Module (black or white, depending on selection)
5. Component Identification
The module features a dual LED display and control buttons on the front panel. For a visual reference, please see the product images. The main components are:

- OUT: Output indicator (LED)
- S key: Set key
- ▼IR key: Scroll down (click) / Restart (press for 3 seconds)
- ▲ key: Turn up
- LED1: Green power-on timing digital tube
- Point (next to LED1): Indicates power-on timing in hours
- Point (below LED1): Indicates power-on timer running in minute units
- LED2: Red power-off timing digital tube
- Point (next to LED2): Indicates power-off timer running in hours
- Point (below LED2): Indicates power-off timer running in minute units
6. Wiring Instructions
The module has a terminal block on the back for power input and output connections. Ensure all connections are secure before applying power.

Terminal Connections:
- IN+: Input positive (DC 12V)
- IN-: Input negative pole (DC 12V)
- O-: Output negative
- O+: Output positive
Safety Warning: The output is active. When the relay is energized and closed, the O- and O+ terminals are connected to provide power output. When using, always connect the load first and then turn on the power to avoid short circuits and potential hazards.
Output Power Up/Down Wiring:
The module supports both power-up and power-down control for the output. For detailed wiring diagrams, please refer to the official user manual PDF.
Output Power Up: Connect the load to the output terminals such that power is supplied to the load when the relay is active.
Output Power Down: Connect the load to the output terminals such that power to the load is cut off when the relay is active (or vice-versa, depending on the specific control logic desired).
7. Setup and Parameter Setting
The module allows for easy parameter configuration through its buttons.
Entering the Code Menu:
- Press and hold the S button for 6 seconds to enter the code menu.
Entering Parameter Setting Mode:
- Double-click the S key to enter the parameter setting mode.
Parameter Descriptions:
- P0: Power-on timing unit
- Default parameter P0=0: Power-on timing unit is seconds.
- Setting P0 to other values allows selection of minutes or hours.
- P1: Power-off timing unit
- Default parameter P1=0: Power-off timing unit is seconds.
- Setting P1 to other values allows selection of minutes or hours.
- P2: Power-on/Shutdown Priority
- Default parameter P2=ON: Power-on work priority.
- Setting P2 to OFF: Power failure and shutdown priority.
- P3: Lock Settings
- Default parameter P3=0: Does not lock the settings.
- Setting P3 to 1: Locks the settings to prevent accidental changes.
Use the ▲ and ▼IR keys to adjust values and navigate through settings.
8. Operating Modes
The T2401-O module supports several operating modes for various timing applications. The following descriptions outline the functionality of each mode. For visual examples of the display during these modes, please refer to the official user manual PDF.
Mode 1: Timed Shutdown
Example: Power off after 6 seconds of work.
- Parameter Settings: Configure the desired timing duration for the power-on state.
- Operation: The timer starts with output active. After the set time (e.g., 6 seconds), the output will turn off (no loop).

Mode 2: Timed Power-on
Example: Power on with a delay of 9 seconds.
- Parameter Settings: Configure the desired timing duration for the delay.
- Operation: The timer starts with no output. After the set delay (e.g., 9 seconds), the output will power on and remain on (not looping).

Mode 3: Cycle Switch (Work then Delay)
Example: First work for 6 seconds, then delay for 9 seconds, infinite loop.
- Parameter Settings: Set both the work duration (P0) and delay duration (P1).
- Operation: The timer starts with output active for the set work duration. Then, the output turns off for the set delay duration. This cycle repeats infinitely.

Mode 4: Cycle Off and On (Delay then Work)
Example: Power on for 6 seconds after shutdown for 9 seconds, infinite loop.
- Parameter Settings: Set both the delay duration (P0) and work duration (P1).
- Operation: The timer starts with no output for the set delay duration. Then, the output turns on for the set work duration. This cycle repeats infinitely.

9. User Tips
No specific user tips are available from buyer reviews or Q&A at this time. Always ensure correct wiring and parameter settings for your specific application.
10. Troubleshooting
- No Display/No Power: Check the DC 12V power supply connections (IN+ and IN-). Ensure the voltage is correct and connections are secure.
- Output Not Activating: Verify that the load is correctly connected to O+ and O-. Check the selected operating mode and timing parameters. Ensure the relay is clicking when it should be active.
- Incorrect Timing: Double-check the P0 and P1 parameter settings for the timing units (seconds, minutes, hours) and the numerical values.
- Settings Not Saving: Ensure you have exited the parameter setting mode correctly. If accidental changes are an issue, consider setting P3 to lock the settings.
- Module Overheating: Ensure the connected load does not exceed the maximum current (20A) or power (240W) ratings. Provide adequate ventilation if operating in an enclosed space.
11. Maintenance
- Keep the module clean and free from dust and moisture.
- Avoid exposing the module to extreme temperatures or direct sunlight.
- Do not attempt to disassemble the module, as this may void any potential warranty and could cause damage.
- Regularly check wiring connections for looseness or corrosion.
12. Warranty and Support
For detailed warranty information and technical support, please refer to the seller or manufacturer's official documentation. A comprehensive user manual in PDF format, which may include additional diagrams and instructions, can be viewed or downloaded here.