Introduction
The DIGITEN DFC15 Liquid Flow Controller is a device designed for precise measurement and control of liquid flow. It can automatically activate or deactivate a solenoid valve when the liquid flow reaches a predefined setting. This system is compatible with hall effect flow sensors and features a large LCD screen that clearly displays flow rate, total volume, and liquid temperature. The DFC15 is suitable for a wide range of applications including swimming pools, water dispensers, coffee machines, drip irrigation systems, and general water metering.
Features
- Quantitative Control: Automatically turns off the solenoid valve when the set flow volume is reached.
- Flow Rate Monitoring: Displays real-time liquid volume passing per minute (LPM/GPM).
- Universal Hall Effect Sensor Compatibility: Works with various hall effect flow sensors by adjusting the K parameter.
- Water Meter Functionality: Can be used to measure the total volume of water.
- Adjustable Accuracy: Allows calibration of measurement accuracy through K parameter adjustment.
- Temperature Monitoring: Includes a temperature sensor to measure liquid temperature.
- Easy-to-Read LCD Display: Front-panel LCD clearly shows total volume, flow rate, and temperature, with custom icons indicating working status.
Technical Specifications
| Parameter | Specification |
|---|---|
| Controller Power Requirement | 12VDC |
| Power Adapter Input | 100-240VAC |
| Power Adapter Output | 12VDC, max 2A |
| Adapter Lead Length | 1m |
| Measuring Accuracy | ±1% |
| Output for Solenoid Valve | 12VDC, max 2A (Controller supports up to 5A, but included adapter is 2A) |
| Temperature Sensor | 0-100°C / 32-212°F, NTC3950, Accuracy: ±1°C/±1°F, Thread: M8 |
| Max Total Volume | 999999 G/L |
| Quantitative Range | 0-9999 G/L |
| Flow Rate Range | 0-9999.99 LPM (GPM) |
| Cable Length (Controller) | 1m |
| Dimensions | 88mm x 126mm x 30mm |
| Weight | 200g |
| Operation Environment Temperature | 0-50°C / 32-122°F |
| Operation Environment Humidity | <85% Relative Humidity |
| G1/2" Flow Sensor Flow Range | 1-30 L/min |
| G1/2" Flow Sensor Max Pressure | 1.75 Mpa |
| G1/2" Flow Sensor Type | Hall effect |
| G1/2" Flow Sensor Cable Length | 15cm |
| G1/2" Flow Sensor Error | ±2% |
| G1/2" Solenoid Valve Working Pressure | 0.02-0.8 Mpa |
| G1/2" Solenoid Valve Operation Mode | N/C (Normally Closed) |
Package Contents
The package includes the following items:
- 1 x DFC15 Controller
- 1 x G1/2" Flow Sensor
- 1 x G1/2" Solenoid Valve
- 1 x Power Adapter (12VDC, 2A)
- 1 x Temperature Sensor
- 1 x User Manual (this document)
Setup and Installation
Follow these instructions for proper installation of the DFC15 system:
- Ensure the solenoid valve and flow sensor are installed with their direction arrows aligned with the water flow.
- The solenoid valve's positive and negative poles can be ignored during wiring.
- Maintain sufficient distance between the controller and water sources to prevent water ingress, especially when powered on.
- Use Teflon tape on threaded connections to ensure a leak-free seal.
- The sensor and valve wires can be extended up to 10 meters if needed.
- Important Power Adapter Note: The DFC15 controller can operate with solenoid valves up to 5A. However, the included power adapter is rated for 2A. If you intend to use a larger solenoid valve (requiring more than 2A), please acquire a suitable higher-current power adapter to prevent overheating or damage to the adapter.
Wiring Diagram Description:
- The power adapter connects to the DC input port on the top right of the controller.
- The solenoid valve connects to the two wires labeled 'Solenoid valve' coming from the controller's main cable harness.
- The temperature sensor connects to the two wires labeled 'Temperature sensor' from the controller's main cable harness.
- The flow sensor connects to the three wires labeled 'Flow sensor' from the controller's main cable harness. Ensure the flow sensor is installed in-line with the water pipe, and the solenoid valve is also installed in-line, typically after the flow sensor.
Operation
LCD Display Instruction
- Quantitative: Displays the set amount for quantitative control.
- Max Alarm: Displays the maximum total volume alarm setting.
- Total: Shows the accumulated total volume.
- PW: Indicates password protection for K parameter settings (default: 1234).
- L: Unit for Liters.
- Gal: Unit for Gallons.
- K: K parameter value for flow sensor calibration.
- LPM: Liters per minute (flow rate unit).
- GPM: Gallons per minute (flow rate unit).
- Liquid Temperature: Displays the measured liquid temperature in Celsius or Fahrenheit.
- Alarm Icon: Flashes when the total flow volume reaches the set alarm value.
- Faucet Icon: Animated water drops appear under the faucet icon in RUN mode.
Key Function Instruction
| Button | Function |
|---|---|
| MENU | Short press to cycle through quantitative setting value, total flow value, and K parameter. Long press after setting to store values and exit setting mode. |
| SET | Long press to enter parameter setting mode. Short press in setting mode to move to the next digit. |
| CLEAR | Long press to clear the corresponding value. |
| ▲ / ▼ | Increase or decrease the displayed number. |
| RUN/STOP | Press once to open the solenoid valve and start operation. Press again to close the solenoid valve and stop operation. |
Function Overview
- Quantitative Control: Set a desired liquid volume. The controller will automatically close the solenoid valve when this volume is reached.
- Max Alarm: Set a maximum total volume. When this value is reached, the controller will alarm, and the bell icon will flash.
- Total Volume Display: Shows the accumulated total volume, with a range of 0-999999.
- Password Protection (PW): The K parameter setting is protected by a 4-digit password (default: 1234). The user must enter the password to adjust the K parameter.
- Volume Unit (L/Gal): Toggle between Liters and Gallons.
- K Parameter: A calibration factor that varies for different flow meters. Adjust this value to fine-tune accuracy.
- Flow Rate Units (LPM/GPM): Displays flow rate in Liters per minute or Gallons per minute.
- Liquid Temperature: Measures and displays liquid temperature in Fahrenheit or Celsius.
- Alarm Indication: The bell icon flashes when the total flow volume reaches the set alarm value.
- Faucet Animation: In RUN mode, the LCD displays an animated water drop under the faucet icon.
View Setting Values
Short press the MENU button to cycle through and view the following values in order: Total volume, Quantitative value, Max alarm value, and K parameter.
Setting Instructions
Before making any settings, press the RUN/STOP button to ensure the controller is in STOP status.
Setting Quantitative Value
- Short press MENU until the display shows "Quantitative".
- Long press SET until the quantitative value flashes.
- Use ▲ or ▼ to change the number.
- Short press SET to move to the next digit.
- Press MENU to save the setting and exit.
Setting Max Alarm Value
- Short press MENU until the display shows "Max alarm".
- Long press SET until the max alarm value flashes.
- Use ▲ or ▼ to change the number.
- Short press SET to move to the next digit.
- Press MENU to save the setting and exit.
Setting K Parameter
The K parameter is crucial for measurement accuracy. Consult the flow sensor manufacturer for the correct K value. You can also adjust it through trial and error to achieve desired accuracy.
- Short press MENU until the display shows "K parameter".
- Long press SET until the LCD displays "---- PW".
- Input the 4-digit password (default is 1234) using ▲/▼ and SET.
- If the password is correct, the controller will switch to modifiable K value. Otherwise, you cannot set the K parameter.
- Use ▲ or ▼ to change the number.
- Short press SET to move to the next digit.
- Press MENU to save the setting and exit.
How to Change Password
- Short press MENU until the display shows "K parameter".
- Long press CLEAR until the LCD displays "---- PW" (password flash).
- Input the current 4-digit password (default: 1234).
- If correct, the controller will allow you to change the password, displaying "IPO---- PW" (Enter new password).
- Enter your new 4-digit password.
- The display will then show "2PO---- PW" (Confirm new password).
- Enter your new password again to confirm.
- Once the password is changed, the LCD will return to the default display.
Note: If you forget your current password, you can restore factory settings, which will revert all settings, including the password, to their default values.
How to Restore Factory Setting
To restore the controller to factory settings, press and hold the RUN/STOP button while connecting power to the device. The controller will then reset all settings to their default values.
How to Change Volume Unit (Liter/Gallon)
To switch the volume unit to Gallons, press the ▲ and ▼ buttons simultaneously. Press them again to revert to Liters.
How to Change Temperature Unit (Celsius/Fahrenheit)
To switch the temperature unit to Fahrenheit, press the MENU and ▲ buttons simultaneously. Press them again to revert to Celsius.
Clear Value
Press the MENU button to navigate to the desired interface (Total volume, Quantitative value, or Max alarm value). Then, long press the CLEAR button for approximately 3 seconds. Only the displayed Total volume, Quantitative value, and Max alarm value can be cleared this way.
Maintenance
The DFC15 Liquid Flow Controller system requires minimal maintenance. Keep the controller clean and dry. Avoid exposing it to direct sunlight or extreme temperatures. Regularly check all connections for tightness and ensure no leaks are present in the plumbing system. If the flow sensor or solenoid valve becomes clogged, clean them according to their respective manufacturer's guidelines.
Troubleshooting
If the controller does not function as expected, verify the wiring, configuration, and settings. If problems persist, use the following procedures to diagnose the issue:
Measuring Inaccuracy
- The accuracy of the controller's measurement largely depends on the flow sensor.
- If measurements are inaccurate, consult the flow meter manufacturer for the correct K value.
- Adjust the K value in the controller settings to achieve the desired accuracy. Note that different liquid media and pressures may require K value adjustments.
- Generally, a smaller diameter flow meter tends to provide more accurate readings.
Power Adapter Overheating or Burning
- This controller can handle loads up to 5A. Ensure that the power adapter's output current rating meets or exceeds the solenoid valve's power requirements.
- If the solenoid valve's power consumption is higher than the adapter's rating, the adapter will overheat and may burn out. Use a suitable power adapter for higher current solenoid valves.
Total Volume and Flow Rate Not Changing in RUN Mode
- If the LCD displays the animated water drop but the total volume and flow rate do not change correctly, try restoring the controller to factory settings.
Controller Works, But Solenoid Valve Does Not
- The green RUN LED lights up when RUN/STOP is pressed, but no water flows.
- Check Solenoid Valve Functionality: Disconnect the solenoid valve from the controller. Connect a 12VDC power source directly to the solenoid valve. If you hear a clicking sound (coil triggering), the solenoid valve is working correctly. If not, replace the solenoid valve.
- Check Controller Output: Use a reliable multi-meter to measure the voltage across the two wires for the solenoid valve coming from the controller. Press RUN/STOP to activate the controller. If the voltage reading is 12VDC, the controller is functioning correctly. If not, proceed to the next step.
- Check Power Adapter: Ensure the power adapter provides 12VDC and its output current meets the solenoid valve's requirements.
If the problem persists after attempting these troubleshooting steps, please contact customer service at service@digit-en.com.
User Tips
- Calibration is Key: For accurate measurements, it is essential to calibrate the K parameter. If you find the dispensed volume is consistently off (e.g., 3 liters dispensed when 5 are set), adjust the K value using the password-protected setting.
- Flow Rate Considerations: If you experience issues with the valve closing or maintaining flow at higher rates (e.g., 8-10 liters/minute), the included G1/2" solenoid valve might be insufficient. Consider upgrading to a larger valve (e.g., 3/4" 12V) if your application requires higher flow.
- Not for High-Density Liquids: This product is primarily designed for water and similar low-viscosity liquids. Its suitability for high-density liquids like molasses is not guaranteed and may affect accuracy or functionality.
- Waterproof Warning: The device is NOT waterproof. Do not install it in water or expose it to rain.