TOMZN TOB1Z-63

Contents

TOMZN TOB1Z-63 DC Circuit Breaker User Manual

Model: TOB1Z-63 | Brand: TOMZN

1. Safety Information

⚠ Warning: To avoid danger of suffocation, keep packaging bags away from babies and children. This bag is not a toy.

This device operates with high voltage. Installation and operation should only be performed by a qualified electrical professional to ensure safety and proper function.

  • Always disconnect power before installation, maintenance, or any adjustments.
  • Ensure adequate ventilation around the device during operation to prevent overheating.
  • Do not place the device near flammable materials.
  • Store the device properly in a dry, safe environment when not in use for extended periods.
Product Certificates for TOMZN TOB1Z-63 DC Circuit Breaker
Figure 1: Product Certificates, including CE, Occupational Health and Safety, Quality, and Environmental Management System certifications.

For a more detailed user manual, please refer to the official PDF document: TOMZN TOB1Z-63 User Manual (PDF).

2. Product Overview

The TOMZN TOB1Z-63 Series DC Miniature Circuit Breaker (MCB) is designed for reliable overloading and short-circuit protection in DC distribution systems and electrical equipment. It is particularly suitable for applications such as photovoltaic (PV) solar systems.

Front view of TOMZN TOB1Z-63 DC Circuit Breaker
Figure 2: Front view of the TOMZN TOB1Z-63 DC Circuit Breaker.

Key features include:

  • Overloading and short-circuit protection.
  • Unique design with a strong permanent magnetism arc system for 6KA short-circuit capability.
  • Long mechanical life (over 20,000 operations) and electrical life (over 8,000 operations).
  • Designed for DIN rail mounting (TH35-7.5 standard stainless type).
  • Clear "ON/OFF" indication via the operating handle.
Labeled diagram of TOMZN TOB1Z-63 DC Circuit Breaker components
Figure 3: Labeled components of the TOB1Z-63 DC Circuit Breaker, including terminals, brand, model number, rated current, wiring diagram, operating handle, fastening screws, breaking capacity, and PC flame retardant material.

3. Specifications

AttributeValue
Model NumberTOB1Z-63
TypeMini Circuit Breaker
Poles Number2
Rated VoltageDC 600V
Rated Current Options3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Characteristic CurveC Curve (5-10In)
Breaking Capacity6KA (IEC60898-1), 6,10,15KA (IEC60947-2)
Mounting35mm DIN Rail
Electrical LifeNot less than 8000 times
Mechanical LifeNot less than 20000 times
Working Ambient Temperature-10°C ~ +40°C
Enclosed Protective ClassIP20
Max. Fuse Connection100AgL (>10KA)
Selective Grade3
CertificationCE
StandardIEC60947, IEC60898, EN IEC 60947-1:2021, EN IEC 60947-3:2021
Dimension diagram of the TOMZN TOB1Z-63 DC Circuit Breaker
Figure 4: Dimension Diagram (A: 80mm Height, B: 36mm Length, C: 35mm Height, D: 66mm Length, E: 45mm Length, F: 80mm Height).
Table of technical specifications for TOB7Z-63 DC MCB
Figure 5: Detailed technical specifications table for the TOB7Z-63 DC MCB.

4. Setup and Installation

Installation of the TOB1Z-63 DC Circuit Breaker should be carried out by a qualified electrician following local electrical codes and safety standards.

  1. Mounting: The circuit breaker is designed for mounting on a 35mm DIN rail. Securely attach the device to the DIN rail using the integrated clips.
  2. Wiring:
    • Ensure all power is disconnected from the circuit before wiring.
    • Pay close attention to the polarity: connect the positive (+) and negative (-) poles correctly.
    • The power input should be connected to the top terminals, and the power output from the underside terminals. This design facilitates installation and cable management.
    • Screw down the terminals firmly to penetrate the insulating layer of the power lines and ensure a tight grip.
  3. Parameter Adjustment: After connecting the equipment, adjust any necessary system parameters according to your specific application requirements.
Wiring diagram for a DC system with circuit breaker, fuse, and surge protector
Figure 6: Example wiring diagram for a DC system, illustrating connections for positive input, negative input, positive output, negative output, and ground wire, incorporating a circuit breaker, fuse, and surge protective device.

5. Operating Instructions

The TOB1Z-63 DC Circuit Breaker operates automatically to protect your circuit. When the current flowing through the device exceeds its specified rated current (overload) or a short circuit occurs, the breaker will automatically trip, interrupting the circuit and protecting connected equipment from damage.

  • To Turn On: Push the operating handle upwards to the "ON" position.
  • To Turn Off: Push the operating handle downwards to the "OFF" position.
  • Trip Indication: If the breaker trips due to an overload or short circuit, the handle will move to an intermediate or "OFF" position. Investigate and resolve the fault before attempting to reset the breaker.
Circuit breaker operating in extreme temperatures
Figure 7: The TOB1Z-63 circuit breaker is designed to function reliably in a wide range of ambient temperatures, from -10°C to +40°C.

6. Maintenance

The TOB1Z-63 DC Circuit Breaker requires minimal maintenance. Regular checks can help ensure its longevity and reliable operation:

  • Visual Inspection: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections.
  • Cleanliness: Keep the device clean and free from dust and debris. Use a dry cloth for cleaning; do not use liquids.
  • Ventilation: Ensure that the area around the circuit breaker has adequate airflow to prevent heat buildup.
  • Storage: If the device is to be stored for an extended period, disconnect it from power and store it in a dry, cool environment.

7. Troubleshooting

If you encounter issues with your circuit breaker, consider the following:

  • Breaker Trips Frequently:
    • An overloaded circuit is the most common cause. Reduce the load on the circuit.
    • A short circuit may be present. Inspect wiring and connected devices for faults.
    • Ensure the rated current of the breaker is appropriate for your application. Using a breaker with a significantly higher rating than the expected load may not provide adequate protection.
  • Device Heats Up During Continuous Operation:
    • Some heating is normal, especially under continuous loads approaching the rated current (e.g., 48-52 continuous amps for a 60A breaker).
    • If heating is excessive, verify proper ventilation and ensure connections are tight. Loose connections can cause resistance and heat.
  • Wiring Issues:
    • Always double-check polarity (+/-) during installation. Incorrect polarity can lead to malfunction or damage.
    • Ensure all wire connections are secure and terminals are tightened properly.

8. User Tips

  • Durability: This circuit breaker has been reported to perform reliably in challenging environments, including solar systems in jungle conditions, for over three years.
  • Value: Users frequently commend the product for its good quality and affordable price.
  • Installation: Many users find the installation straightforward, noting that the product works well once installed.
  • Reliability: The product is often purchased repeatedly by users, indicating satisfaction with its long-term performance.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.