1. Introduction
The TAIYEDQ D52-2058 is a DIN-rail mountable digital multifunction meter designed for measuring various AC electrical parameters. It simultaneously displays AC voltage, AC current, active power, power factor, electrical energy (kWh), and power frequency (Hz). This meter is suitable for household and industrial applications, providing clear and accurate readings.
Figure 1: Front view of the D52-2058 Multifunction Meter
2. Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | D52-2058 |
| Accuracy Class | 1% ± 2 words/digital |
| Display Type | Digital Only, 0.5" LED 9999 display (three lines, red/green) |
| Phase | Single-phase |
| Power Supply | AC |
| Range of Voltage | AC 80-300V or AC 200-450V (selectable) |
| Range of Current | AC 0-100A |
| Measuring Energy Range | 0-99999 kWh |
| Active Power Range | 0-30000W (AC80-300V), 0-45000W (AC200-450V) |
| Power Frequency | 45.00-65.00Hz |
| Power Factor | 1.000-0.000 |
| Measurement Speed | 2 times per second |
| Power Consumption | <0.2VA |
| Dimensions (W x H x D) | 54 x 80 x 64 mm |
| Operating Temperature | -10°C to 65°C |
| Humidity | 20-80% |
| Weight | 120g / pc |
Figure 2: D52-2058 Meter Dimensions
3. Product Components and Functions
The D52-2058 meter features a clear digital display and a single control button. Key indicators and functions are as follows:
- Display: Shows Power Factor (cosΦ), AC Voltage (V), Frequency (Hz), AC Current (A), Electrical Energy (kWh), and Active Power (W).
- SAM CK Button: Used to switch between display modes and reset electrical energy.
- Terminals 1 & 2: For connecting the measuring voltage.
- Terminals 3 & 4: For connecting the external current transformer (CT) secondary wires.
Figure 3: Display Indications and Switch
Figure 4: Multifunction Capabilities
4. Installation and Wiring
The D52-2058 meter is designed for DIN-rail installation. Ensure all power is disconnected before installation to prevent electric shock.
4.1. DIN-Rail Installation
The meter features a clip mechanism on the back for easy mounting onto a standard DIN rail. Simply align the meter with the DIN rail and press firmly until it clicks into place.
Video 1: Product demonstration including DIN-rail installation.
4.2. Wiring Diagram
Follow the wiring instructions carefully. The meter requires connection for both voltage measurement and current measurement.
- Connect the measuring voltage to terminals 1 and 2.
- For AC current lower than 100A, connect the internal current transformer (CT) by making the wire pass through the hole in the meter. The direction can be chosen arbitrarily.
- For external current transformer applications, connect the two wires of the secondary transformer to terminals 3 and 4.
Figure 5: Wiring Diagram for AC Current Measurement (less than 100A)
Note: Please select the correct voltage range model (AC 80-300V or AC 200-450V) when ordering, as this affects the measurement capabilities.
5. Operation
- Power On: Once powered, the meter will automatically display the measured results for AC Voltage (V), AC Current (A), and Active Power (W). The corresponding red LED indicators will light up.
- Switching Display Modes: Press the "SAM CK" button (located on the left side of the meter) to cycle through different measurement displays. Each press will change the display to show Power Factor (cosΦ), Power Frequency (Hz), and Electric Energy (kWh). The correlative red or green LED will light up to indicate the currently displayed parameter.
- Returning to Default Display: Press the "SAM CK" button again after cycling through all parameters, and the meter will return to displaying AC Voltage, AC Current, and Active Power.
- Resetting Electric Energy (kWh): The meter saves the value of electric energy and continues accumulating it even after power cycles. To reset the electric energy (kWh) to zero, press and hold the "SAM CK" button for five seconds while the meter is displaying electric energy (indicated by the green kWh LED). Release the button to restart accumulation from zero.
Figure 6: Energy Clear Function
6. Maintenance
- Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the meter to extreme temperatures or humidity outside its specified operating range.
- Ensure all connections are secure and free from corrosion.
- The meter features a flame-retardant shell for safety.
Figure 7: Flame Retardant Shell
7. Troubleshooting
- No Display: Check power connections to terminals 1 and 2. Ensure the voltage is within the meter's specified range (AC 80-300V or AC 200-450V).
- Incorrect Readings: Verify wiring connections, especially for current measurement. Ensure the current wire passes correctly through the internal CT hole or that the external CT is properly connected to terminals 3 and 4.
- Energy (kWh) Not Resetting: Ensure you are pressing and holding the "SAM CK" button for at least five seconds while the kWh display is active.
- Internal Component Issues: If internal components require inspection or replacement (e.g., due to erased markings on chips), it is recommended to contact qualified technical support or the manufacturer.
8. User Tips
- Always double-check your wiring before applying power to ensure correct operation and prevent damage.
- The meter's display is always active when powered; there is no function to turn off the display.
- Consider testing the meter's readings against a known accurate device after installation to confirm proper functionality.
9. Important Attention / Warnings
This meter is designed to measure 50Hz AC city electricity ONLY. It will be damaged if used to measure square wave, output of an inverter, or correction sine wave. Using it with incompatible power sources will void any warranty and may cause damage to the device or connected systems.
National patent number of meter: 20143023106.2
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's specific terms and conditions or contact the point of purchase. Keep your purchase receipt as proof of purchase.
For additional information and documents, you may refer to the official user manual PDF: View User Manual (PDF)