1. Introduction
This document provides instructions for the diymore 25A 3S/4S/5S 18650 Li-ion Lithium Battery Protection Board Module (BMS PCM). This module is designed to protect Li-Polymer and LiMnO battery cells (3.6V/3.7V nominal) during charging and discharging cycles, ensuring safety and extending battery life. It features protection against overcharge, over-discharge, overcurrent, and short circuits.

2. Specifications
| Feature | Specification |
|---|---|
| Application | Computer (General electronic projects) |
| Type | Voltage Regulator / Battery Protection Module |
| Brand Name | diymore |
| Condition | New |
| Package | SMD |
| Single Cell Overcharge Protect Voltage | 4.23 - 4.28V |
| Single Cell Overcharge Recover Voltage | 4.08 - 4.18V |
| Overcharge Protect Delay | 0.5 - 1.5S |
| Single Cell Over-discharge Protect Voltage | 2.72 - 2.88V |
| Single Cell Over-discharge Recover Voltage | 2.9 - 3.1V |
| Overcharge Protect Current | 60A |
| Over-discharge Protect Current | 60A |
| Over-discharge Protect Delay | 0.5 - 1.5S |
| Temperature Protection | YES |
| Disconnect Protection | YES |
| Shortage Protection | YES |
| Shortage Delay | 100 - 600μS |
| Shortage Protect Recover | YES |
| Charging Current | 25A |
| Discharging Current | 25A |
| Charging Voltage (3S) | 12.6V |
| Charging Voltage (4S) | 16.8V |
| Charging Voltage (5S) | 21V |
3. Setup and Wiring
Careful wiring is essential for the correct and safe operation of the BMS module. Refer to the diagrams below for connecting your battery cells, charger, and load.
3.1 General Wiring Principles
- Connect the battery cells in series as indicated by the 'B-', 'B1', 'B2', 'B3', 'B4', 'B+' terminals.
- The 'P-' terminal is the negative output for both charging and discharging.
- The 'P+' terminal is the positive output for both charging and discharging.
- Ensure all connections are secure and correctly polarized.
- The board itself has clear markings for each connection point.
3.2 Wiring Diagrams
The following diagrams illustrate the connections for 3S, 4S, and 5S battery configurations. Please select the diagram corresponding to your specific BMS board and battery pack.



3.3 NTC Thermistor Connection
The board includes NTC contacts on the reverse side. These are for connecting an external NTC thermistor (temperature sensor) to provide temperature protection for the battery pack during charging and discharging. This helps prevent overheating.

4. Operating Instructions
Once correctly wired, the BMS module will automatically manage the battery pack's safety features.
4.1 Charging
- Connect your charger to the P- and P+ terminals.
- The BMS will prevent overcharging by cutting off the charge current if any cell voltage exceeds the overcharge protection voltage (4.23 - 4.28V).
- Ensure your charger provides the correct voltage for your battery configuration (e.g., 12.6V for 3S, 16.8V for 4S, 21V for 5S). Using a lower voltage for charging (e.g., 19V for a 5S pack) will result in an undercharged battery.
4.2 Discharging
- Connect your load to the P- and P+ terminals.
- The BMS will prevent over-discharging by cutting off the discharge current if any cell voltage drops below the over-discharge protection voltage (2.72 - 2.88V).
- Overcurrent protection will activate if the discharge current exceeds 60A.
- Short-circuit protection will activate if a short circuit is detected, with a delay of 100-600μS.
5. Maintenance
- Keep the module dry and clean. Avoid exposure to moisture or corrosive substances.
- Avoid physical impact or excessive bending of the board.
- Regularly inspect wiring for loose connections or damage.
- Ensure adequate ventilation if the module is enclosed, especially during high current operation.
6. Troubleshooting
- Low Output Voltage (e.g., 7V for 5S): This could indicate a problem with one or more battery cells, or a defective BMS board. Check individual cell voltages. If cells are healthy, the BMS might be faulty.
- Frequent Protection Trips (e.g., in power tools): For high-current applications like screwdrivers, a 25A continuous discharge current might be insufficient, leading to overcurrent protection activation. Consider a BMS with a higher current rating (e.g., 40A or more) for such uses.
- Battery Not Fully Charging: Ensure your charger provides the correct voltage for your battery configuration (e.g., 21V for a 5S pack). A lower voltage will not fully charge the battery.
- No Charge Indicator: This BMS module is a protection board, not a smart charger. It does not have built-in charge indicators. It primarily cuts off current when protection limits are reached.
- Difficulty Distinguishing 3S/4S/5S Boards: Refer to the markings on the board itself and the number of balance wire connection points. The wiring diagrams also clearly show the number of cells.
7. User Tips
- This BMS board is well-suited for replacing NiMH cells in power tools with lithium-ion batteries, provided the current requirements are met.
- Always double-check your wiring against the provided diagrams and the markings on the board to prevent damage.
- For applications requiring high burst currents, such as cordless drills, consider using a BMS with a higher continuous discharge current rating (e.g., 40A) to avoid premature cut-offs.
- Utilize the NTC thermistor connection for enhanced temperature monitoring and protection of your battery pack, especially during charging.
8. Warranty and Support
For warranty information, technical support, or further inquiries, please contact the seller directly. A detailed user manual in PDF format may also be available for download from the seller's product page or via this link: User Manual (PDF).