The HLK-5M05 is a 5W ultra-small series AC-DC power module designed by Shenzhen Hi-Link Electronics Co., Ltd. This module offers high efficiency, low power consumption, and high reliability, making it suitable for a wide range of applications including smart home devices, industrial control systems, communication equipment, and instrumentation.
Video: Overview of the HLK-5M05 power module.
2. Product Features
- Ultra-thin, ultra-small design.
- Global universal input voltage range (85~265Vac).
- Low power consumption with no-load loss less than 0.1W.
- Low ripple and noise output.
- Integrated output overload and short-circuit protection with self-recovery.
- High efficiency and power density.
- Input and output isolation voltage of 3000Vac.
- 100% full load aging and testing.
- High reliability and long lifespan (MTBF > 100,000 hours).
- Meets UL and CE safety requirements, designed for EMC and safety testing.
- Environmentally friendly waterproof plastic potting, providing moisture, vibration, water, and dust resistance (IP65 standards).
- Cost-effective solution, works without external circuits.
- 1-year quality guarantee.
3. Specifications
3.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | Hi-Link |
| Model Number | HLK-5M05 |
| Power Source | AC&DC |
| Output Power | 5W |
| Output Type | Single |
| Certification | CE, RoHS |
| Origin | Mainland China |
| Warranty | 1 Year |
| Protection | OCP (Over Current Protection), OVP (Over Voltage Protection), SCP (Short Circuit Protection) |
| Working Time | >100,000 hours |
3.2 Input Characteristics
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| Rated input voltage | 100~240 | Vac | |
| Input voltage range | 85-264 | Vac | Or 70-350Vdc |
| Maximum input current | ≤0.2 | A | |
| Input inrush current | ≤10 | A | |
| Input low start | ≤50 | mS | |
| Long-term reliability (MTBF) | ≥100,000 | h | |
| External fuse recommended | 1A / 250Vac or 10Ω wire wound resistance | Slow blow |
3.3 Output Characteristics (HLK-5M05: 5V/1000mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 5.0±0.1 | Vdc | |
| Full load rated output voltage | 5.0±0.2 | Vdc | |
| Short-time maximum output current | ≥1200 | mA | |
| Long time maximum output current | 1000 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, full load) | ≥69 | % | |
| Input high voltage efficiency (Vin=230Vac, full load) | ≥70 | % | |
| Output ripple and noise (mVp-p) | ≤100 | mV | Rated input voltage, full output load. With 20MHz bandwidth oscilloscope, Load side test with 10uF and 0.1uF capacitors. |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load) ≤5 | %Vo | |
| Output over-current protection | Output maximum load 110-150% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No damage to the whole device |
4. Environmental Conditions
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| Working temperature | -25—+60 | °C | |
| Storage temperature | -40—+80 | °C | |
| Relative humidity | 5—95 | % | |
| Thermal methods | Natural cooling | ||
| Atmospheric pressure | 80—106 | Kpa | |
| Altitude | ≤2000 | m | |
| Vibration | Vibration coefficient 10~500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes | Meets requirements for secondary road transportation |
5. Setup and Connection
5.1 Typical Application Circuit
The diagram above illustrates a typical application circuit for the HLK-5M05 module. It includes recommended external components for optimal performance and safety.
5.2 Recommended External Components
Notes:
- The fuse and varistor are basic protective circuits and MUST be connected.
- If authentication/certification is required, the Safety capacitance and common-mode inductance should NOT be omitted.
- C2 filter capacitor can reduce the output ripple from the original 50mV to 30mV.
6. Safety Features and Compliance
6.1 Certifications
The product design meets UL and CE safety certification requirements. (UL and CE certifications are made by the customer and need to be designed according to the reference circuit.)
6.2 Safety and Electromagnetic Compatibility (EMC)
- Input Protection: Designed with a UL listed 1A/250Vac slow-blow fuse or 10Ω wire-wound resistor.
- PCB Material: Double-sided copper clad foil, with a material fire resistance grade of 94-V0.
- Safety Standards: Complies with UL1012, EN60950, UL60950.
- Insulation Voltage: Input-to-Output (I/P-O/P) insulation voltage: 2500Vac.
- Insulation Resistance: I/P-O/P > 100M Ohms / 500Vdc at 25°C and 70% RH.
- Conduction and Radiation: Meets EN55011, EN55022 (CISPR22).
- Electrostatic Discharge: Meets IEC/EN 61000-4-2 level 4 (8kV/15kV).
- Radio Frequency Radiation Immunity: Meets IEC/EN 61000-4-3.
6.3 Temperature Safety Design
- At room temperature, the capacitors and the inner surface of the main converter do not exceed 90°C.
- The maximum shell surface temperature does not exceed 60°C.
7. Marking, Packaging, Transportation, and Storage
7.1 Product Marking
Each product features a unique bar code mark at an appropriate location to ensure traceability of manufacturing date, product batch, and other relevant information. The content complies with national and industry standards.
7.2 Packaging Marking
The product box is marked with the manufacturer's name, site, zip code, product model, and manufacturing date (year, month, day). It also includes transport signs such as "up", "moisture-proof", and "handle with care", all in accordance with GB 191 provisions.
7.3 Packaging
Products are packaged using special plastic boxes with separated compartments, providing anti-vibration protection. Packaging conforms to GB 3873 standards.
7.4 Transportation
Packaged products can be transported by any means. During transit, they should be covered (awning) and protected from violent vibration, impact, or other damage.
7.5 Storage
Product storage must comply with the requirements of GB3873.
8. Dimensions and Weight
- Dimensions (L x W x H): 38mm x 23mm x 18mm
- Weight: 32 ± 1g
Pin Functions
| Pin | Function |
|---|---|
| 1 | AC |
| 2 | AC |
| 3 | -Vo (Output Negative) |
| 4 | +Vo (Output Positive) |
Dimensional error: Length, width, height and pin pitch error ± 8%; Pin length error ± 1mm; Pin diameter error -0.2mm.
9. User Tips
While no specific user tips were provided, here are some general recommendations for working with power modules:
- Always ensure correct polarity when connecting the module to your circuit to prevent damage.
- Verify input voltage is within the specified range (85-264Vac) to avoid overvoltage or undervoltage conditions.
- Consider adding an external fuse as recommended in the specifications for enhanced safety.
- Ensure adequate ventilation around the module, especially when operating at higher loads or ambient temperatures, to maintain optimal performance and lifespan.
- When designing your PCB, follow best practices for power supply layout, including proper grounding and trace width for current paths.
10. Troubleshooting
If you encounter issues with your HLK-5M05 module, consider the following common troubleshooting steps:
- No Output Voltage:
- Check input voltage: Ensure the input voltage is within the 85-264Vac range.
- Check connections: Verify all input and output connections are secure and correctly polarized.
- Check external fuse: If an external fuse is used, ensure it is not blown.
- Check for short circuits: Disconnect the load and check if the module provides output. If it does, there might be a short circuit in your load.
- Unstable Output Voltage / High Ripple:
- Check load: Ensure the load current does not exceed the maximum output current (1000mA).
- Check external filter capacitor (C2): Ensure the recommended C2 filter capacitor is correctly installed and functioning.
- Check for noise sources: Ensure there are no external electromagnetic interference sources affecting the module.
- Overheating:
- Check load: Reduce the load to ensure it is within the module's rated capacity.
- Check ambient temperature: Ensure the operating ambient temperature is within the specified range (-25°C to +60°C).
- Ensure proper ventilation: Make sure the module has sufficient airflow for natural cooling.
If the issue persists after these steps, refer to the detailed PDF manual or contact customer support.
11. Warranty and Support
The HLK-5M05 power supply module comes with a 1-year quality guarantee from the date of purchase.
For detailed technical information, application notes, and further support, please refer to the official user manual PDF:
For any inquiries or technical assistance, please contact Shenzhen Hi-Link Electronic Store customer service.