DIGITEN DFC15 Liquid Flow Controller User Manual

Model: DFC15

Brand: DIGITEN

Introduction

This liquid flow controller (DFC15) is a device used to measure and control the flow of liquids. The DFC15 can control a solenoid valve to turn on/off when the flow reaches a preset value. It is suitable for hall effect flow sensors and features a large LCD screen that displays the flow rate, volume, and temperature of the liquid. The DFC15 has wide applications, including swimming pools, water dispensers, coffee machines, drip irrigation systems, and water meters.

A detailed user manual in PDF format is available for download from the manufacturer's website or via the provided link: DFC15 User Manual (PDF).

Features

  • Quantitative Control: The controller automatically turns off the solenoid valve when the flow reaches a user-defined amount.
  • Flow Rate Monitoring: Displays the real-time volume of liquid passing per minute.
  • Compatibility: Works with all hall effect flow sensors, adjustable via the K value.
  • Water Meter Functionality: Can be used to measure the total volume of water.
  • Adjustable Accuracy: Calibration of accuracy through K parameter adjustment.
  • Temperature Monitor: Includes a temperature sensor to measure liquid temperature.
  • Easy-to-Read LCD: Displays total flow volume, flow rate, and sensed temperature clearly, with custom icons indicating working status.

Technical Specifications

Parameter Value
Controller Power Requirement 12VDC
Power Adapter Input 100-240VAC
Power Adapter Output 12VDC, max 2A
Adapter Lead Length 1m
Measuring Accuracy ±1%
Output for Solenoid Valve 12VDC, max 2A (Note: Controller supports up to 5A, but included adapter is 2A)
Temperature Sensor 0-100°C / 32-212°F, NTC3950, Accuracy: ±1°C/±1°F, Thread: M8
Max Total Volume 999999 G/L
Quantitative Range 0-9999.99 G/L
Flow Rate Range 0-9999.99 LPM (GPM)
Cable Length 1m
Dimensions 88mm x 126mm x 30mm
Weight 200g
Operation Environment Temperature 0-50°C / 32-122°F
Operation Environment Relative Humidity <85%

LCD Display Instruction

The LCD provides a clear overview of the controller's status and measurements. Refer to the diagram below for an explanation of each display element.

Diagram of DFC15 LCD display with numbered labels
Figure 1: DFC15 LCD Display Layout
  1. Quantitative: A certain setting amount.
  2. Max alarm: Alarm of total volume.
  3. Total: Total volume.
  4. PW: Password (default: 1234).
  5. L: Liter unit.
  6. Gal: Gallon unit.
  7. K: K parameter.
  8. LPM: Liters per minute.
  9. GPM: Gallons per minute.
  10. Liquid temperature: Current liquid temperature.
  11. Alarm icon: Indicates an alarm condition.
  12. Faucet icon: Indicates water flow in RUN mode.

Key Function Instruction

Button Function
MENU Press to switch the query between quantitative setting value, total flow value, and K parameter. After setting, press MENU to store the setting value and exit setting mode.
SET Long press to enter parameter setting mode. Short press in setting mode to change to the next digit.
CLEAR Long press to clear the corresponding value.
▲ / ▼ Increase or decrease the number.
RUN/STOP Press once to open the solenoid valve, press again to close the solenoid valve.

Function Instruction

  1. Quantitative: Set an expected value. When the flow reaches this value, the controller automatically closes the solenoid valve.
  2. Max alarm: When the total amount reaches the set value, the controller will alarm and the bell symbol will flash.
  3. Total: Displays the total accumulated volume, with a range of 0-999999.
  4. PW: Password. This K-value protection password must be entered by the user when setting the K parameter.
  5. L/Gal: Volume unit selection between Liter and Gallon.
  6. K: K parameter. Different flow meters may require different K values for accurate measurement.
  7. LPM/GPM: Flow rate unit selection between Liters per minute (LPM) and Gallons per minute (GPM).
  8. Liquid temperature: Displays the liquid temperature in Fahrenheit or Celsius degrees, measured by the temperature sensor.
  9. Alarm: The bell icon flashes when the total flow volume reaches the set alarm value.
  10. Faucet: In RUN mode, the LCD displays an animated water drop under the faucet icon.

Setting Instructions

Before making any settings, press the RUN/STOP button to ensure the controller is in STOP status.

View Setting Values

Short press the MENU button to cycle through and view the following values:

Total volume → Quantitative value → Max alarm value → K parameter

Setting Quantitative Value

  1. Short press MENU until the display shows "Quantitative".
  2. Long press SET until the quantitative value flashes.
  3. Use ▲ or ▼ to change the number.
  4. Short press SET to move to the next digit.
  5. Press MENU to save the setting and exit.

Setting Max Alarm Value

  1. Short press MENU until the display shows "Max alarm".
  2. Long press SET until the max alarm value flashes.
  3. Use ▲ or ▼ to change the number.
  4. Short press SET to move to the next digit.
  5. Press MENU to save the setting and exit.

Setting K Parameter

The K parameter is crucial for accurate flow measurement. Consult the flow sensor manufacturer for the correct K value. You can also adjust it to fine-tune accuracy.

Diagram showing the steps to set the K parameter, including password entry.
Figure 2: K Parameter Setting Process
  1. Short press MENU until the display shows "K parameter".
  2. Long press SET until the LCD displays "---- PW".
  3. Input the 4-digit password (default is 1234). If correct, the controller will switch to modifiable K value. Otherwise, you cannot set the K parameter.
  4. Use ▲ or ▼ to change the number.
  5. Short press SET to move to the next digit.
  6. Press MENU to save the setting and exit.

Note: Please ask the manufacturer for the flow sensor K value. You can adjust the K value until you satisfy the measuring accuracy.

How to Change Password

  1. Short press MENU until the display shows "K parameter".
  2. Long press CLEAR until the LCD displays "---- PW" (password flash).
  3. Input the current 4-digit password (default is 1234). If correct, the controller will allow you to change the password.
  4. The display will show "1P0---- PW" (Enter new password). Enter your new 4-digit password.
  5. The display will show "2P0---- PW" (Confirm new password). Re-enter your new 4-digit password.
  6. Use ▲ or ▼ to change the number for each digit.
  7. Once the controller password has been changed, the LCD will return to the default display.

Note: If you forget the current password, you can restore factory settings, which will reset all setting values, including the password, to factory defaults.

How to Restore Factory Setting

Keep pressing the RUN/STOP button while connecting power to the device. The controller will then restore factory settings.

How to Change Volume Unit (Liter/Gallon)

To convert to Gallon unit, press the ▲ and ▼ buttons simultaneously. Press them again to return to Liter unit.

How to Change Temperature Unit (Celsius/Fahrenheit)

To convert to Fahrenheit unit, press the MENU and ▲ buttons simultaneously. Press them again to return to Celsius unit.

Clear Value

Press the MENU button to switch to the desired interface (Total volume, Quantitative value, or Max alarm value). Long press the CLEAR button for about 3 seconds. Only the value displayed on the current interface will be cleared.

Installation Instruction

Proper installation is crucial for the DFC15 to function correctly. Follow these steps carefully:

Wiring diagram for DFC15 showing connections for power adapter, solenoid valve, temperature sensor, and flow sensor.
Figure 3: DFC15 Installation and Wiring Diagram
  1. Ensure the solenoid valve and flow sensor are installed in the same direction as the water flow.
  2. The positive and negative poles of the solenoid valve can be ignored for connection purposes.
  3. Keep sufficient distance between the controller and water sources to prevent water from entering the controller when powered on.
  4. Use Teflon tape on threaded connections where required to ensure no leaks.
  5. The sensor wires can be extended up to 10 meters if needed.

Note: This controller can work with solenoid valves up to 5A. However, the included power adapter is 2A. If you are using a larger solenoid valve, please use a suitable power adapter that meets its current requirements to prevent overheating or damage.

How to Work

After setting the K parameter, quantitative value, and Max alarm value, and properly installing the flow sensor and solenoid valve:

  1. Press the RUN/STOP button. The controller will begin operation.
  2. The display will continuously show the accumulated total flow volume and the current flow rate. The faucet icon will animate.
  3. When the flow reaches the set quantitative value, the controller automatically closes the solenoid valve.
  4. The total volume and animation will stop changing, and the flow rate will return to zero.
  5. To repeat the process, press the RUN/STOP button again.

Troubleshooting

If the controller does not function properly, verify that the unit is wired, configured, and set correctly. If problems persist, use the following procedures:

Measuring Inaccuracy

The accuracy of controller measurement generally depends on the flow sensor.

  • If measurement accuracy is inaccurate, consult the flow meter factory for an accurate K value.
  • Adjust the K value to achieve the desired accuracy. Note that different liquid media and pressures may require K value adjustments.
  • A smaller diameter flow meter generally provides more accurate readings.

Power Adapter Very Hot or Burned

This controller can work with loads up to 5A. Confirm if the power adapter meets the solenoid valve's power requirements. If the solenoid valve's power consumption exceeds the adapter's capacity, the adapter will become very hot and may burn out.

Total Volume and Flow Rate Don't Change in RUN Mode

If the LCD displays an animated water drop but the total volume and flow rate do not change properly, please restore the controller to factory settings.

Controller Works, But the Solenoid Valve Doesn't Work

The green RUN LED is lit when RUN/STOP is pressed, but water is not released.

  1. Check Solenoid Valve: Disconnect the solenoid valve from the controller. Connect a 12VDC power source directly to the solenoid valve. If you hear a coil triggering sound, the valve is working. Otherwise, replace the solenoid valve.
  2. Check Controller Output: Use a reliable multi-meter to measure the voltage across the two wires for the solenoid valve when the controller is in RUN mode. If the voltage reads 12VDC, the controller is working correctly.
  3. Check Power Adapter: Ensure the power adapter provides 12VDC and its output current meets the solenoid valve's requirements.

User Tips

  • For precise liquid dispensing, such as filling aquariums, utilize the quantitative control feature by setting the desired volume.
  • If you experience inaccurate water metering, adjust the K parameter. This is a key step for calibration and can significantly improve accuracy.
  • To program automatic closing when a specific volume is reached, use the 'Quantitative' setting as described in the 'Setting Quantitative Value' section.

Warranty and Support

DIGITEN products are guaranteed to the original owner for one year against defects in workmanship and materials. For support or warranty claims, please contact us:

If troubleshooting steps do not resolve your issue, please send your questions to our customer service email.

Warnings

  • This device is not waterproof. Do not install it in water.
  • Avoid exposing the device to rain or excessive moisture.
  • Ensure the power adapter's output current matches the solenoid valve's requirements to prevent overheating or damage.
  • Keep the controller away from water sources to prevent accidental water ingress, especially when powered on.