1. Safety Information
WARNING: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or playpens. This bag is not a toy.
This device operates with high voltage. Installation and maintenance should only be performed by a qualified electrical professional. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Do not place the device near flammable materials.
- Ensure adequate ventilation during operation.
- Disconnect from power and store properly when not in use for extended periods.
2. Product Overview
The TOMZN TOB3L-32F is a Residual Current Circuit Breaker with Over Current and Leakage Protection (RCBO). It is designed to provide comprehensive protection against various electrical faults in commercial and domestic installations.
Key Protections:
- Earth Faults: Detects and interrupts current leakage to earth.
- Overloads: Protects circuits from excessive current draw.
- Short Circuits: Rapidly disconnects power during a short circuit event.
- Over-voltage: Provides protection against voltage surges.
The RCBO features both disconnected neutral and phase, ensuring proper actuation against earth leakage faults even if neutral and phase connections are reversed. It incorporates a filtering device to prevent unwanted tripping due to transient voltages and currents.

3. Setup and Installation
- Professional Installation: After receiving the product, it is mandatory to have a qualified electrical professional perform the installation and operation.
- Mounting: The TOB3L-32F is designed for 35mm DIN rail mounting.
- Wiring: Connect the equipment in accordance with the wiring diagram specifications provided below. Ensure all connections are secure and correctly polarized.


4. Operating Instructions
- Power On/Off: Use the T-shaped operating handle to switch the circuit breaker ON (up position) or OFF (down position).
- Parameter Adjustment: If applicable, adjust equipment parameters according to specific system requirements after installation.
- Test Button: The yellow test button is used to verify the functionality of the residual current protection. Press this button monthly to ensure the device is operating correctly. A functional device will trip (switch to OFF) when the test button is pressed. Reset the handle to ON after testing.

5. Maintenance
- Monthly Testing: Press the yellow test button monthly to ensure the residual current protection function is active. If the device does not trip, it may be faulty and should be replaced by a qualified electrician.
- Ventilation: Ensure the installation area has adequate ventilation to prevent overheating.
- Storage: When not in use for extended periods, disconnect the device from power and store it in a dry, safe place.
- Cleaning: Keep the device clean and free from dust. Use a dry cloth for cleaning; do not use liquids or abrasive cleaners.
6. Troubleshooting
- Device Trips Frequently: This could indicate an overload, short circuit, or earth leakage fault in the connected circuit. Investigate the circuit for faults. If no fault is found, the device may be overly sensitive or faulty.
- Device Does Not Trip During Monthly Test: This indicates a malfunction in the residual current protection mechanism. The device is unsafe and must be replaced immediately by a qualified electrician.
- Smoke or Burning Smell: If you observe smoke, a burning smell, or any unusual behavior, immediately disconnect power to the circuit and contact a qualified electrician. Do not attempt to operate the device.
- Device Shuts Down Under Load: If the device trips when a load is applied, it may be due to the load exceeding the rated current of the breaker, or an actual fault condition (overload, short circuit, leakage). Verify the load requirements and check for faults.
7. Specifications
| Parameter | Value |
|---|---|
| Model Number | TOB3L-32F |
| Type | Residual Current Circuit Breaker (RCBO) |
| Number of Poles | 1P+N |
| Rated Current (In) | 6A, 10A, 16A, 20A, 25A, 32A |
| Rated Operating Current (IΔn) | 30mA |
| Rated Voltage (V) | AC230V (220V/230V~) |
| Short-Circuit Breaking Capacity (Inc) | 6000A |
| Endurance | ≥6000 times |
| Residual Current-Off Time | ≤0.1S |
| Design | A AC |
| Residual Current Scope | 0.5IΔn-1n |
| Mounting | 35mm DIN Rail |
| Certification | CE |
| Standard | IEC61009 |
| Operating Temperature | -5°C to +40°C |
| Dimensions (W x H x D) | 18mm x 78mm x 74.8mm |


8. User Tips
- Professional Installation is Key: Always have a qualified electrician install this device to ensure safety and proper function.
- Regular Testing: Make it a habit to press the test button monthly. This simple check can prevent serious electrical hazards.
- Understand Tripping: If your breaker trips, it's usually doing its job. Don't just reset it; try to identify the cause (e.g., too many appliances on one circuit, a faulty appliance).
- Environmental Conditions: Ensure the breaker is installed within its specified operating temperature range (-5°C to +40°C) and in a well-ventilated area.
9. Applicable Regulations and Harmonized Standards
This product complies with the following directives and standards:
- Low Voltage Directive (LVD): 2014/35/EU
- Electromagnetic Compatibility Directive (EMC): 2014/30/EU
- Restriction of the Use of Certain Hazardous Substances (RoHS) Directive: 2011/65/EU
- Standard: IEC61009
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Always refer to the official user manual PDF for the most comprehensive and up-to-date information: TOMZN TOB3L-32F User Manual (PDF).