1. Introduction

Thank you for choosing the ZHURUI PR10 Power Recorder. This device is designed to accurately measure and record various electrical parameters of your appliances. It features a 2.4-inch TFT color LCD screen for clear display of power, power factor, voltage, current, frequency, total power consumption, total power consumption time, electricity cost, single power consumption, single power consumption time, and electricity cost. The PR10 also records daily power consumption and electricity cost in real-time, allowing you to view historical data in chart or list format for up to 30 years. It is suitable for monitoring electrical equipment in households, factories, and offices, and includes functions for scheduled power on/off.

ZHURUI PR10-F Power Recorder with display showing voltage, current, power, and energy consumption data.
Figure 1: ZHURUI PR10-F Power Recorder Front View

2. Safety Information

WARNING: Do not open the device or attempt to replace parts yourself if a malfunction occurs, to avoid electric shock. There are no user-replaceable parts inside this device. In case of malfunction, please contact the manufacturer or an authorized distributor.

  • The recorder cannot work in high-temperature and high-humidity environments. Please use it within the normal temperature and humidity range.
  • The working voltage range of the recorder should be kept between AC 85V and AC 265V.
  • The working current cannot exceed the maximum working current.
  • Do not expose the recorder to environments with excessive dust, corrosive gases, or other harmful substances during storage and use.
  • Do not touch the conductor parts of the socket plug of the instrument during use to avoid electric shock.

3. Packing List

Please check the package contents upon receipt:

  • PR10 Power Recorder: 1 piece
  • User Manual: 1 copy
  • Warranty Card: 1 copy
  • Product Certificate: 1 piece

4. Product Overview and Main Features

The PR10 Power Recorder is equipped with a 2.4-inch TFT color LCD screen for clear data visualization. It can measure and record various electrical parameters and offers extensive functionality for energy monitoring and management.

Main Features:

  • Display: 2.4-inch TFT color LCD display.
  • Operation: Fully digital operation and control with four intuitive buttons.
  • Accuracy: 0.5-class measurement accuracy.
  • Multi-language Support: User interface available in 9 languages (Chinese, English, Spanish, German, French, Italian, Russian, Japanese, Korean).
  • Currency Units: 23 types of currency units available for free setting.
  • Date & Time: Date display, time setting, supporting 5 date formats.
  • Power-on State: Configurable for automatic power-on, no power-on, or maintaining the last power-off state.
  • Energy Statistics: Provides total and current power consumption statistics. Current power consumption can be cleared for specific measurements.
  • Display Modes: Three main display pages: overview, current power consumption, and real-time electrical parameters.
  • Historical Data: Automatically records historical power consumption data for up to 30 years, viewable as charts or lists.
  • Electricity Rate: Supports up to 4 decimal places, adjustable. Includes an 8-time-period stepped pricing function for peak-valley pricing.
  • Timers: 9 groups of timers. Two advanced timers for specific date/time/day (every day, working day, or weekend) and seven general timers for specific time periods daily.
  • Alarm Function: Alerts when voltage, current, power, or temperature exceeds set alarm values.
  • Output Protection: Automatically cuts off power if voltage, current, power, or temperature exceeds set protection values. Features a start-up overload mode and automatic recovery.
  • Energy-saving: Screen can be set to automatically turn off after 1, 5, or 10 minutes of inactivity, or remain always on. Measurement continues when the screen is off.
  • System Functions: Options to clear total power consumption, clear historical records, and restore factory settings.
  • Resolution: Automatic power measurement resolution switching (0.01W for <100W, 0.1W for ≥100W, 1W for ≥1000W).
  • Over-range Prompt: Indicates when measurements exceed the device's range.
  • Plug Types: Available in 6 different plug types (New National Standard 10A five-hole, National Standard 16A three-hole, European Standard 16A, French Standard 16A, American Standard 15A, and British Standard 13A).
Back view of the ZHURUI PR10 Power Recorder showing product name, model, accuracy, working voltage, max power, manufacturer, and safety notice.
Figure 2: ZHURUI PR10-F Power Recorder Back View

5. Specifications

General Specifications:

ParameterValue
Brand NameZHURUI
Model NumberPR10-F BS 13A
ZHURUI ModelPR10
OriginMainland China
CertificationCE
DIY SuppliesElectrical
Display TypeDigital Only
Power SupplyAC
Rated Voltage230V
Operating VoltageAC85V~AC265V
Operating Frequency45~65Hz
Max Operating Current19A & Under
Power Range0.1-3250W@250V
Power Consumption≤2.5W
Energy Range0~999999kWh
PF Range0-1.000
Accuracy Class0.5
Phasesingle phase
Operating Temperature0~40°C
Humidity<90%RH
Dimensions (L×W×H)125mm x 79mm x 38.5mm (excluding plug)
Weight165g
Battery IncludedYes (for memory, CR2032)
Hign-concerned ChemicalNone

Electrical Measurement Accuracy:

ParameterMeasurement RangeResolutionMeasurement Accuracy
VoltageAC85~265V0.1V±(0.5%FS+0.1V)
Power (PR10-F)0.1~3250W0.01W±(0.5%FS+0.01W)
Current (British Standard 13A)0.005~13A0.001A±(0.5%FS+0.001A)
Power factor0~1.0000.001±(0.5%FS+0.001)
Frequency45~65Hz0.1Hz±(0.5%FS+0.1Hz)
Electricity Cost0~9999990.01±(0.5%FS+0.01)
Power Consumption0~999999kWh0.00001kWh±(0.5%FS+0.00001kWh)

Notes:

  • Measured values of voltage and current are true RMS values.
  • Measured power value is active power.
  • Power resolution: <100W (0.01W, ±0.5%FS+0.01W); ≥100W (0.1W, ±0.5%FS+0.1W); ≥1000W (1W, ±0.5%FS+1W).
  • Electricity cost resolution: <10000 Yuan (0.01 Yuan, ±0.5%FS+0.01 Yuan); ≥10000 Yuan (0.1 Yuan, ±0.5%FS+0.1 Yuan); ≥100000 Yuan (1 Yuan, ±0.5%FS+1 Yuan).
  • Power consumption resolution is adjusted according to the measurement result, up to 0.00001 kWh.

Timing Specifications:

  • Timing Range: 999 Days 23 Hours 59 Minutes
  • Timing Resolution: 1 Minute
Diagram showing the dimensions of the ZHURUI PR10 Power Recorder: Width 79mm, Length 125mm, Height 39mm, Pins 22.5mm.
Figure 3: Product Dimensions

6. Setup and Installation

The ZHURUI PR10-F Power Recorder is designed for simple plug-and-play operation. Ensure you have the correct plug type for your region (BS/UK plug for this model).

  1. Plug the PR10-F Power Recorder into a standard wall socket.
  2. Plug the appliance you wish to monitor into the socket on the front of the PR10-F.
  3. The device will power on and display the overview page by default.
  4. If the device does not power on, long-press the "Δ/Ο" button for three seconds to turn on the power, or navigate to the "Switch Setting" page and set the switch state to "Power On".

Video Demonstration:

Video 1: Demonstration of the PR10 Power Recorder's features and menu navigation.

7. Operating Instructions

The PR10 Power Recorder is operated using four buttons located on the right side of the display. These buttons allow you to navigate menus, adjust settings, and view data.

Button Functions:

Button NameFunction (Main Page)Function (Setting Page)
≡/<J (Set/Confirm)Press to display the system menu.Confirm number/jump to next item; check/uncheck box; select radio button; confirm button.
Δ/Ο (Up/Switch)Long press to turn on or off the socket output.Decrease value; jump to previous setting item.
∇/Ο (Down/Switch)Press to switch main display pages; long press to display device serial number.Increase value; jump to next setting item.
Ο/Ο (Return/Clear)Long press to reset current power consumption, electricity cost, and time.Exit setting page without saving changes.

Status Bar Icons:

  • Alarm Icon: Flashes when an alarm event occurs.
  • Timer Icon: Displayed when the timer is turned on.
  • Output Off Icon: Displayed when the socket output is off.
  • Output On Icon: Displayed when the socket output is on.
  • Main Page 1/2/3 Icon: Displayed when in Main Page 1, 2, or 3 respectively.

Main Display Pages:

The PR10 has three main display pages that can be switched using the "∇/Ο" button:

  1. Overview Page: Displays total and one-shot energy consumption, cost, and time.
  2. Current Power Consumption Page: Shows detailed current power consumption data.
  3. Real-Time Electrical Parameter Page: Displays real-time voltage, current, power, power factor, and frequency.

8. Viewing Historical Records

The PR10 Power Recorder automatically stores historical power consumption data for up to 30 years. You can view this data in various chart and list formats.

  1. From the working state, press the "≡/<J" button to pop up the system menu.
  2. Use the "∇/Ο" or "Δ/Ο" buttons to select "Historical Records". The selected item will be highlighted with a blue background and white text.
  3. Press the "≡/<J" button to enter the historical records sub-menu.
  4. Use the "∇/Ο" or "Δ/Ο" buttons to select the desired format: "Monthly Chart", "Monthly List", "Annual Chart", or "Annual List".
  5. Press the "≡/<J" button again to view the historical record page.
Screenshots of the PR10 display showing Year-chart, Year-list, Month-chart, and Month-list for historical energy consumption and bill data.
Figure 4: Historical Records Display Examples

9. Function Settings

To access and modify the device settings:

  1. From the working state, press the "≡/<J" button to pop up the system menu.
  2. Use the "∇/Ο" or "Δ/Ο" buttons to select the desired menu item. The selected item will be highlighted.
  3. If a sub-menu exists, press "≡/<J" to enter it, then select the sub-menu item and press "≡/<J" again. If no sub-menu, press "≡/<J" to enter the setting page directly.
  4. Press the "Ο/Ο" button to exit the setting page.

9.1. Language Setting

You can change the display language of the device.

  1. Enter the language setting page via the system menu.
  2. Use the "∇/Ο" or "Δ/Ο" buttons to move the cursor to the desired language.
  3. Press the "≡/<J" button to set the selected language.
  4. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.
Screenshot of the PR10 display showing language selection options: Chinese, English, Spanish, German, French, Italian, Russian, Japanese, Korean.
Figure 5: Language Selection Screen

9.2. Currency Settings

Set the currency unit for cost calculations.

  1. Enter the currency unit setting page via the system menu.
  2. Use the "∇/Ο" or "Δ/Ο" buttons to move the cursor to the desired currency unit.
  3. Press the "≡/<J" button to set the selected currency unit.
  4. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.3. Electricity Cost Setting (Charge Rate)

Configure the electricity rate, including stepped pricing if applicable.

  1. Enter the electricity cost setting page (under "General Settings").
  2. Use "∇/Ο" to move the cursor to the "Enable segment charge" checkbox. Check if time-of-use pricing is needed.
  3. Use "∇/Ο" to move to "Decimal digits" and use "∇/Ο" or "Δ/Ο" to set the decimal precision for the electricity cost.
  4. Press "≡/<J". If segment charge is enabled, you will set individual segment charges. If not, set a single electricity rate.
  5. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.4. Date Format Setting

Choose how the date is displayed.

  1. Enter the date format setting page via the system menu.
  2. Use the "∇/Ο" or "Δ/Ο" buttons to select the desired date format.
  3. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.5. Time Setting

Set the current date and time.

  1. Enter the time setting page via the system menu.
  2. The tens digit of the year will be highlighted. Use "∇/Ο" or "Δ/Ο" to adjust the value, then "≡/<J" to confirm and move to the next digit.
  3. Repeat for all digits (year, month, day, hour, minute, second).
  4. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.6. Timer Setting (Advanced Timers 1 & 2)

Advanced timers allow for scheduled power on/off at specific dates and times, or on recurring days.

  1. Enter the timer setting page for "Timer 1" or "Timer 2" via the system menu.
  2. Press "≡/<J" to start setting. The "Enable" checkbox will be highlighted.
  3. Select whether to enable the timer. Then set the start time (date and time).
  4. Select the time option: "No Repeat" (one-time), "Every Day", "Work day" (Mon-Fri), or "Weekend" (Sat-Sun).
  5. Select the switch action: "Power ON" or "Power OFF".
  6. Press "≡/<J" to save settings and exit, or "Ο/Ο" to exit without changes.

9.7. Timer Setting (General Timers 3-9)

General timers allow for scheduled power on/off at specific times daily.

  1. Enter the timer setting page for "Timer 3" through "Timer 9" via the system menu.
  2. Press "≡/<J" to start setting. The "Enable" checkbox will be highlighted.
  3. Select whether to enable the timer. Then set the start time (hour and minute).
  4. Select whether to repeat "Everyday".
  5. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.8. Outlet Setting (Power-on State)

Configure the state of the outlet after the device powers on.

  1. Enter the switch setting page via the system menu.
  2. Use "∇/Ο" or "Δ/Ο" buttons to select the desired power-on state: "On" (always on), "Off" (always off), or "Same as last time" (remembers previous state).
  3. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.9. Alarm Settings

Set alarms for various electrical parameters.

  1. Enter the alarm setting page via the system menu.
  2. Press "≡/<J" to start setting. The voltage value will be highlighted.
  3. Use "∇/Ο" or "Δ/Ο" buttons to adjust the alarm voltage value. Press "≡/<J" to confirm and move to the enable checkbox.
  4. Check/uncheck the "Enabled" box for voltage alarm.
  5. Repeat steps 3 and 4 for Current, Power, and Temperature alarm settings.
  6. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.10. Output Protection Settings

Configure automatic power cut-off based on parameter thresholds.

  1. Refer to the alarm setting method to set the protection parameters for voltage, current, power, and temperature.
  2. Select whether to allow "Start-up Overload". Check this box if the start-up current of the connected equipment (e.g., motor) might exceed the protection current. In this mode, current and voltage are not detected for the first 15 seconds if the current is above 2A.
  3. Select whether to allow "Automatic Recovery". If enabled, the recorder will automatically turn on power after one minute if the parameters return to normal after an output protection event.
  4. Press "≡/<J" to save and exit, or "Ο/Ο" to exit without saving.

9.11. Screen Setting

Adjust the screen's auto-off behavior to save power.

  1. Enter the screen setting page via the system menu.
  2. Use "∇/Ο" or "Δ/Ο" buttons to select the desired auto-off time: "Turn off screen after 1 minute", "Turn off screen after 5 minutes", "Turn off screen after 10 minutes", or "Screen never turn off".
  3. Move the cursor to "OK" and press "≡/<J" to save and exit, or press "Ο/Ο" to exit without saving.

9.12. System Setting (Clear Data, Factory Reset)

This section allows you to clear recorded data or reset the device to factory defaults.

  1. Enter the system setting page via the system menu.
  2. Use "∇/Ο" or "Δ/Ο" buttons to select the desired option: "Clear total Energy", "Clear History", or "Factory Reset".
  3. Press "≡/<J" to confirm the operation. A confirmation dialog box will appear.
  4. Use "∇/Ο" or "Δ/Ο" to select "OK" and press "≡/<J" to perform the operation, or press "Ο/Ο" to exit without performing.
  5. Caution: "Factory Reset" will clear all power consumption record data. Use with care.

10. Troubleshooting

Refer to the table below for common problems and their solutions.

Problem PhenomenonSolution
Device is not powered on after plugging in.Long-press the "Δ/Ο" button for three seconds to turn on the power, or go to "Switch Setting" and set the outlet state to "Power On".
Device power is cut off during operation (output protection icon flashes).The recorder has entered the output protection state. Check if voltage, current, power, or temperature exceed set protection values. Adjust protection settings or disable them if necessary.
Recorder beeps and alarm icon flashes during operation.The recorder has entered the alarm state. Check if voltage, current, power, or temperature exceed set alarm values. Adjust alarm settings or disable them if necessary.
Time and total power consumption are not saved after power-off.The built-in button battery is dead and needs to be replaced. The model of the button battery is: CR2032.

11. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, direct sunlight, or high humidity.
  • Do not use abrasive cleaners or solvents on the device.
  • Store the device in a cool, dry place when not in use.
  • If the internal CR2032 battery needs replacement (indicated by loss of time/total energy data after power-off), it is recommended to contact customer support or a qualified technician.

12. Warranty and Support

For more information, technical support, or warranty inquiries, please contact Shenzhen Zhurui Technology Co., Ltd. using the details below:

Please retain your purchase receipt and warranty card for future reference.

© 2016 Shenzhen Zhurui Technology Co., Ltd. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.