1. Introduction
Thank you for choosing the ZHURUI PR10 Power Recorder. This device features a 2.4-inch TFT color LCD screen and is designed to measure and record various electrical parameters of appliances, including power, power factor, voltage, current, frequency, total power consumption, total power consumption time, electricity cost, single power consumption, single power consumption time, and electricity cost. It records daily power consumption and electricity cost in real-time, with historical data viewable in charts or lists for up to 30 years.
The PR10 Power Recorder is ideal for detecting and recording the operation and power consumption of electrical equipment in households, factories, offices, and other locations. It also allows for scheduled power on/off of electrical equipment.
2. Package Contents
Please check the package contents upon receipt:
- PR10 Power Recorder: 1 piece
- User Manual: 1 copy
- Warranty Card: 1 copy
- Product Certificate: 1 piece
3. Safety Precautions
DANGER!
Do not open the device or replace parts yourself if a malfunction occurs, to avoid electric shock. There are no replaceable parts inside the device. In case of malfunction, please contact the manufacturer or an authorized distributor.
- The recorder cannot work in high-temperature and high-humidity environments. Please use it within the normal temperature and humidity range.
- The working voltage range of the recorder should be kept between AC 85V and AC 265V.
- The working current cannot exceed the maximum working current.
- Do not expose the recorder to environments with excessive dust, corrosive gases, and other harmful substances during storage and use.
- Do not touch the conductor parts of the socket plug of the instrument during use to avoid electric shock.
4. Product Features
- Fully digital operation and control.
- 2.4-inch TFT color LCD display.
- 0.5-class measurement accuracy.
- Freely switchable between Chinese, English, Spanish, German, French, Italian, Russian, Japanese, and Korean language interfaces.
- 23 types of currency units available for free setting.
- Four operation buttons.
- Date display, time can be set, supporting 5 date formats.
- After power-on, it can be set to automatic power-on, no power-on, or maintain the working state after the last power-off.
- Power consumption statistics are divided into total power consumption and current power consumption. The current power consumption can be cleared with one key, which is convenient for measuring power consumption and electricity cost in specific occasions.
- In working mode, three main display pages can be switched: overview, current power consumption, and real-time electrical parameter page.
- Automatically records historical power consumption data, view historical records in the form of lists or charts, and can store power consumption data for up to 30 years.
- The electricity rate supports up to 4 decimal places, and the number of decimal places can be adjusted freely. It supports 8-time-period stepped pricing function, which is convenient for peak-valley pricing occasions.
- 9 groups of timers in total, including 2 advanced timers for specific date/time power on/off, and 7 general timers for specific time period power on/off daily, on working days, or weekends.
- Alarm function: set to alarm when voltage, current, power, or temperature exceeds set values.
- Output protection function: automatically cuts off power when voltage, current, power, or temperature exceeds set values. Supports start-up overload mode and automatic recovery.
- Energy-saving setting: screen can automatically turn off after 1, 5, or 10 minutes of no operation, or never turn off. Measurement continues when the screen is off.
- Functions for clearing total power consumption, historical records, and restoring factory settings.
- Automatic power measurement resolution switching: 2 decimal places for power < 100W, 1 decimal place for power > 100W, no decimal places for power >= 1000W.
- Over-range prompt.
- Available in various plug types: new national standard 10A five-hole, national standard 16A three-hole, European standard 16A, French standard 16A, American standard 15A, and British standard 13A.
- Small size, exquisite appearance, easy to carry, suitable for measuring various electrical equipment.
5. Product Models and Appearance
The PR10 Power Recorder is available in several models to accommodate different plug types. Please select the appropriate model for your region.
Video Demonstration:
A video demonstrating the PR10's interface navigation, settings, and various measurement capabilities.
6. Technical Specifications
Electrical Measurement Specifications
| Parameter | Measurement Range | Resolution | Measurement Accuracy |
|---|---|---|---|
| Voltage | AC85~265V | 0.1V | ±(0.5%FS+0.1V) |
| Power (PR10-A) | 0.1~2500W | 0.01W | ±(0.5%FS+0.01W) |
| Current (New National Standard 10A) | 0.005~10A | 0.001A | ±(0.5%FS+0.001A) |
| Power (PR10-B) | 0.1~4000W | 0.01W | ±(0.5%FS+0.01W) |
| Current (National Standard 16A) | 0.005~16A | 0.001A | ±(0.5%FS+0.001A) |
| Power (PR10-C) | 0.1~4000W | 0.01W | ±(0.5%FS+0.01W) |
| Current (European Standard 16A) | 0.005~16A | 0.001A | ±(0.5%FS+0.001A) |
| Power (PR10-D) | 0.1~4000W | 0.01W | ±(0.5%FS+0.01W) |
| Current (French Standard 16A) | 0.005~16A | 0.001A | ±(0.5%FS+0.001A) |
| Power (PR10-E) | 0.1~3750W | 0.01W | ±(0.5%FS+0.01W) |
| Current (American Standard 15A) | 0.005~15A | 0.001A | ±(0.5%FS+0.001A) |
| Power (PR10-F) | 0.1~3250W | 0.01W | ±(0.5%FS+0.01W) |
| Current (British Standard 13A) | 0.005~13A | 0.001A | ±(0.5%FS+0.001A) |
| Power factor | 0~1.000 | 0.001 | ±(0.5%FS+0.001) |
| Frequency | 45~65Hz | 0.1Hz | ±(0.5%FS+0.1Hz) |
| Electricity Cost | 0~999999 | 0.01 | ±(0.5%FS+0.01) |
| Power Consumption | 0~999999kWh | 0.00001kWh | ±(0.5%FS+0.00001kWh) |
Notes:
- [1] The measured values of voltage and current are true RMS values.
- [2] The measured power value is active power.
- [3] When the power is less than 100W, the resolution is 0.01W, and the measurement accuracy is ±(0.5%FS+0.01W); when the power is more than or equal to 100W, the resolution is 0.1W, and the measurement accuracy is ±(0.5%FS+0.1W); when the power is more than or equal to 1000W, the resolution is 1W, and the measurement accuracy is ±(0.5%FS+1W).
- [4] When the electricity cost is less than 10000 Yuan, the resolution is 0.01 Yuan, and the measurement accuracy is ±(0.5%FS+0.01 Yuan); when the electricity cost is more than or equal to 10000 Yuan, the resolution is 0.1 Yuan, and the measurement accuracy is ±(0.5%FS+0.1 Yuan); when the electricity cost is more than or equal to 100000 Yuan, the resolution is 1 Yuan, and the measurement accuracy is ±(0.5%FS+1 Yuan).
- [5] The resolution of power consumption is adjusted according to the measurement result, up to 0.00001 kWh.
Other Specifications
| Parameter | Value |
|---|---|
| Operating Voltage | AC85-265V |
| Operating Frequency | 45~65Hz |
| Operating Temperature | 0~40°C |
| Humidity | <90%RH |
| Dimensions (L×W×H, excluding plug) | 125mm×79mm×38.5mm (PR10-A, PR10-B, PR10-E, PR10-F) |
| Dimensions (L×W×H, excluding plug) | 125mm×79mm×56.5mm (PR10-C, PR10-D) |
| Weight | 180g (PR10-A, PR10-B, PR10-E, PR10-F) |
| Weight | 205g (PR10-C, PR10-D) |
7. Setup & Operation
7.1 Button Description
| Button Name | Function (Main Page) | Function (Setting Page) |
|---|---|---|
| ≡/<J "Set/Confirm" Button | Press to display the system menu. | When encountering a number, confirm the number and jump to the next setting item; when encountering a check box, check or uncheck the check box; when encountering a radio button, select the radio button at the current cursor position and jump to the next setting item; when encountering a button, confirm the current setting. |
| △/O "Up/Switch" Button | Long press to turn on or off the socket output. | When encountering a number, decrease the value at the current cursor position; when encountering a check box, radio button or button, jump to the previous setting item. |
| ▽/O "Down/Switch" Button | Press to switch the display of main pages; long press to display the device serial number. | When encountering a number, increase the value at the current cursor position; when encountering a check box, radio button or button, jump to the next setting item. |
| ↩/O "Return/Clear" Button | Long press to reset the current power consumption, current electricity cost and current power consumption time. | Press this button to exit the setting page without saving the current changes. |
7.2 Working Interface
The PR10 features three main display pages:
- Main Page 1 (Overview): Displays total and one-shot energy consumption, cost, voltage, power, current, and power factor.
- Main Page 2 (OneShot): Focuses on one-shot energy consumption and cost.
- Main Page 3 (Real-Time Parameter): Shows real-time power, voltage, current, power factor, and frequency.
Use the "▽/O" button to switch between these main pages.
7.3 Function Settings Overview
To access the system menu for settings, press the "≡/<J" button from any working state. Use the "▽/O" or "△/O" buttons to navigate through menu items, and "≡/<J" to confirm or enter a sub-menu. Use "↩/O" to exit without saving changes.
- Language Setting: Choose from 9 languages.
- Currency Setting: Select from 23 currency units.
- Electricity Cost Setting: Configure charge rates, including stepped pricing for up to 8 time periods.
- Date Format Setting: Choose from 5 date formats.
- Time Setting: Adjust the current date and time.
- Timer Setting: Set up to 9 timers (2 advanced, 7 general) to automatically turn appliances on/off at specific times or days.
- Outlet Setting: Define the outlet state after power on (On, Off, or Same as last time).
- Alarm Setting: Configure alarms for voltage, current, power, or temperature exceeding set limits.
- Output Protection Setting: Set protection limits for voltage, current, power, or temperature to automatically cut off power. Includes options for start-up overload and auto-recovery.
- Screen Setting: Adjust screen auto-off time (1, 5, 10 minutes) or keep it always on.
- System Setting: Options to clear total energy, clear history, and perform a factory reset.
8. Viewing Historical Records
The PR10 stores historical power consumption data for up to 30 years, which can be viewed in charts or lists.
- Press the "≡/<J" button in the working state to pop up the system menu.
- Press the "▽/O" or "△/O" button to select the "Historical Records" menu item.
- Press the "≡/<J" button again to enter the historical record viewing page.
- Within the historical records page, use the "△/O" or "▽/O" buttons to select between "Monthly Chart", "Monthly List", "Annual Chart" or "Annual List".
- Press the "≡/<J" button again to view the selected historical record.
9. Troubleshooting
| Problem Phenomenon | Solution |
|---|---|
| After power-on, the device is not powered on, and the icon is displayed in the lower right corner of the screen. | Long-press the "△/O" button for three seconds to turn on the power, or enter the "Switch Setting" page, set the switch state to "Power-on", and the recorder will automatically turn on the power to supply power to the device when it is powered on next time. |
| During the working process, the device power is cut off, the icon is displayed, or the icon flashes. | The recorder has entered the output protection state. Check whether the voltage, current, power, and temperature exceed the set output protection values. If necessary, you can change the corresponding output protection setting values, cancel the corresponding output protection settings, or check the "Allow Start-up Overload" check box. |
| During the working process, the recorder beeps, and the icon in the lower right corner of the screen flashes. | The recorder has entered the alarm state. Check whether the voltage, current, power, and temperature exceed the set alarm values. If necessary, you can change the corresponding alarm setting values or cancel the corresponding alarm settings. |
| The time and total power consumption are not saved after power-off. | The built-in button battery is dead and needs to be replaced. The model of the button battery is: CR2032. |
*During the setting process, long-pressing the "△/O" button or "▽/O" button can realize quick adjustment.
10. User Tips
- The internal battery (CR2032) is primarily for saving settings and data, not for powering the display when unplugged.
- The device supports multi-tariff settings, allowing you to configure up to 8 time-period stepped pricing zones (e.g., day/night rates).
- The screen can be set to automatically turn off after 1, 5, or 10 minutes of inactivity to save power, or it can be set to remain always on. Measurement continues even when the screen is off.
- All measurement data is stored internally on the device and cannot be directly exported to a PC.
- The device measures electricity passing through it and displays parameters like power factor (PF).
11. Warranty & Support
Legal Statement
Copyright © 2016 Shenzhen Zhurui Technology Co., Ltd. All rights reserved.
Without the written permission of Shenzhen Zhurui Technology Co., Ltd., no unit or individual shall arbitrarily extract or copy part or all of this manual, and shall not disseminate it in any form. The products described in this manual may contain hardware and software with copyrights owned by Shenzhen Zhurui Technology Co., Ltd. and its possible licensors. Unless otherwise permitted in writing by the relevant right holders, no one may copy, distribute, lease, transfer the aforementioned hardware and software in any form or commit other infringing acts.
Within the scope permitted by relevant laws, Shenzhen Zhurui Technology Co., Ltd. may modify the content of this manual under any circumstances.
For More Information
For additional support or information, you may refer to the official user manual PDF: View User Manual (PDF).
- Tel: +86-15002097109
- E-mail: sillin@sina.com
- Website: http://www.zhurui-tec.com