DIANQI THC15A

Contents

THC15A Digital Programmable Timer Switch User Manual

Model: THC15A

1. Introduction

The DIANQI THC15A (AHC15A) is a weekly programmable digital time switch designed for precise control of electrical circuits. It features advanced pre-setting capabilities for up to one week, with daily programs and up to 20 ON/OFF settings. This timer switch is suitable for various applications, offering both automatic and manual override functions. It includes a lithium battery for power reserve and automatic time error correction.

2. Safety Information

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power before installing or servicing the device.
  • Ensure proper wiring according to the provided diagrams and local electrical codes.
  • Do not expose the device to moisture or extreme temperatures outside the specified ambient range.
  • This device should be installed by a qualified electrician.

3. Package Contents

Upon opening the package, please ensure all items are present and undamaged:

  • 1 x THC15A Digital Programmable Timer Switch
  • User Manual (this document)

If any parts are missing or damaged, please contact customer support.

4. Technical Specifications

FeatureSpecification
Model NumberTHC15A
Voltage RatingAC 220V 50/60Hz (Order voltage: 12V, 24V, 36V, 48V, 110V, 220V options available)
Voltage LimitAC 180V~250V
Hysteresis≤1 sec/day (at 25°C)
ON/OFF Operation20 ON & 20 OFF settings
Power Consumption2VA (max)
DisplayLCD
Service Life (Mechanical)107
Service Life (Electrical)105
Minimum Interval1 minute
Load Capacity (Contact Type)16A/250V AC
Load Capacity (Straight Type)10A/250V AC
Switching Contact1 changeover switch
Power Reserve3 years (Lithium battery)
Ambient Temperature-10 ~ +40°C
Ambient Humidity35 ~ 85% RH
WeightApprox. 100g

5. Display and Button Functions

The THC15A features an LCD display and several control buttons for programming and manual operation.

Close-up of the THC15A timer switch display and control buttons.
Figure 1: THC15A Display and Buttons
KeyFunction
PTIMER (Program Setting)
D+DAT (Day Selection)
H+HOUR (Hour Adjustment)
M+MIN (Minute Adjustment)
ClockClock Mode
CRESET (Clear Settings)
MANUALManual Override
C/RCancel/Recovery

6. Setup and Installation

6.1 DIN Rail Installation

The THC15A is designed for easy DIN rail mounting. Simply clip the device onto a standard 35mm DIN rail.

6.2 Wiring Diagrams

The THC15A timer switch is available in two main configurations: 1NO (Normally Open) and 1NO1NC (Normally Open and Normally Closed). Ensure you use the correct wiring diagram for your specific model and application.

Wiring diagram for 1NO and 1NO1NC configurations of the THC15A timer switch.
Figure 2: Wiring Diagram for 1NO and 1NO1NC Models

Contact Type Connection Diagram (1NO1NC):

Contact Type Connection Diagram for THC15A timer switch.
Figure 3: Contact Type Connection Diagram

For the 1NO1NC model, connect the Neutral (N) and Live (L) input wires to the corresponding terminals. The output terminals (1, 2, 3) provide both Normally Open (NO) and Normally Closed (NC) contacts. Connect your load to the appropriate output terminals based on your desired operation.

Straight Type Connection Diagram (1NO):

Straight Type Connection Diagram for THC15A timer switch.
Figure 4: Straight Type Connection Diagram

For the 1NO model, connect the Neutral (N) and Live (L) input wires to the corresponding terminals. The output for the load is typically connected between the 'LOAD' terminal and the Neutral line.

Visual Guide: For a visual demonstration of wiring and initial setup, please refer to the video below:

Video 1: THC15A Installation and Basic Troubleshooting

7. Operating Instructions

7.1 Initial Setup

  1. Start the Machine: Press the "RESET" key (C button) to initialize the timer.
  2. Set Current Time: After pressing the RESET key, if you want to set the present time, press the Clock icon (Clock) button. Then, press D+, H+, M+ to adjust the current day, hour, and minute.

7.2 Programming ON/OFF Times

To enter programming mode and set your desired ON/OFF times, follow these steps:

StepKeyProgramming Action
1Press PSetting 1 ON time (display '1 on')
2Press H+/M+Set hours and minutes for ON time
3Press D+Select specific days or all days for this ON time
4Press PSetting 1 OFF time (display '1 off')
5Press H+/M+Set hours and minutes for OFF time
6Press D+If you want the same day setting as ON time, you do not need to press this key
7Repeat steps 2-6Set 2-20 ON/OFF times as needed
8Press Clock iconEnd programming and return to clock mode

If you do not require all 20 settings, press the Clock icon (Clock) button to exit programming mode early.

7.3 Important Notes for Programming

  • Time settings should follow a logical sequence (e.g., ON time before OFF time). Cross-setting times is not allowed.
  • The system will automatically exit programming mode if there is no operation within 10 seconds, and any unsaved data will be lost.
  • Functions D+, H+, and M+ cannot be used simultaneously.
  • If the device has not been used for a long time, press the "H+" and "D+" keys simultaneously for 2 seconds to turn off the display.

8. User Tips

  • Versatile Applications: This timer relay can be connected to a wide range of devices, from lighting fixtures to various household appliances, depending on your specific needs and the load capacity.
  • 24-Hour Functionality: The timer supports full 24-hour programming, allowing for precise scheduling throughout the day.
  • Check for Damage: Upon receiving your product, carefully inspect the packaging and the device itself for any signs of damage that may have occurred during shipping. Damaged units may not function correctly.

9. Troubleshooting

9.1 Screen Not Displaying

  1. Reinstall Lid: If the protective lid falls off, please reinstall it securely.
  2. Press RESET: If the screen is not displaying, press the "RESET" button (C button) using a pointed object (e.g., a pen tip or small screwdriver).
  3. Charge Battery: If the screen still doesn't display after pressing RESET, the internal lithium battery may be depleted. Connect the timer to a power source and charge it for 12 hours, then try pressing the "RESET" button again.

9.2 Incorrect Operation or Unexpected Behavior

  • Check Wiring: Verify that all connections are secure and follow the appropriate wiring diagram for your model (1NO or 1NO1NC). Loose or incorrect wiring can cause malfunctions.
  • Review Programming: Double-check your ON/OFF programming steps to ensure they are set correctly and logically. Remember that time settings cannot be cross-set.
  • Power Supply: Ensure the timer is receiving stable power within its specified voltage range.

10. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the timer switch. Do not use abrasive cleaners or solvents.
  • Environment: Keep the device in a dry environment, away from direct sunlight, excessive heat, and corrosive substances.
  • Battery: The internal lithium battery has a power reserve of approximately 3 years. It is not user-replaceable. If the battery fails after its lifespan, the unit may need to be replaced or professionally serviced.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the point of purchase. Keep your purchase receipt as proof of purchase.

12. Frequently Asked Questions (FAQ)

Q: What kind of devices can I connect to this relay?
A: This relay is versatile and can be connected to a wide range of electrical loads, such as lighting, fans, water pumps, and other household or industrial appliances, provided they do not exceed the specified load capacity (16A/250V AC for contact type, 10A/250V AC for straight type).
Q: Does the timer support 24-hour programming?
A: Yes, the THC15A timer supports full 24-hour programming, allowing you to set ON/OFF times for any hour of the day.
Q: Where can I buy replacement batteries for the timer?
A: The THC15A timer switch uses an internal lithium battery for power reserve, which is designed to last approximately 3 years. This battery is not intended to be user-replaceable. If the battery fails, the unit may require professional servicing or replacement.