diymore FC-66

Contents

diymore FC-66 DC 12V Photoresistor Relay Module Instruction Manual

Model: FC-66

1. Introduction

This manual provides detailed instructions for the diymore FC-66 DC 12V Photoresistor Relay Module. This module is designed for light detection and brightness control applications, enabling automatic switching of devices based on ambient light conditions. It features adjustable sensitivity and delay timing, making it suitable for various automation tasks, such as controlling street lights or car lights.

The module is sensitive to light in dark conditions or when no light is present. It utilizes a photoresistor as the default light-sensitive sensor. For specific applications requiring a single-shot photodiode, a photodiode probe would be needed.

2. Key Features

  • High-performance quality delay chip design.
  • Adjustable light detection and brightness sensitivity via potentiometer.
  • Adjustable relay on-time and off-time functions.
  • Direct control of high current loads.
  • Protection against power reverse polarity.
  • Wide range of power input wiring options.

3. Specifications

ParameterValue
Supply VoltageDC 6-14V
Current Consumption> 500mA
Maximum Relay Load220V AC 10A or 30V DC 10A
Delay Time Range1-190 seconds (adjustable)
Operating Temperature-40 to 85℃
Dissipation Power6W
Package TypeSOP
Module TypeModule

4. Component Overview

Front view of the FC-66 Photoresistor Relay Module with labeled components.
Figure 1: Front view of the FC-66 Photoresistor Relay Module. Key components include the relay (SRD-12VDC-SL-C), power and time adjustment potentiometers, DC+ / DC- power input terminals, and the sensor input terminal.
Back view of the FC-66 Photoresistor Relay Module showing PCB traces and relay contact labels.
Figure 2: Back view of the FC-66 module, illustrating the PCB layout and the relay output terminals labeled 'Normally Closed', 'Common', and 'Normally Open' in Chinese characters.
Angled view of the FC-66 module highlighting the potentiometers for adjustment.
Figure 3: Close-up view of the FC-66 module showing the two blue potentiometers used for adjusting brightness detection sensitivity and delay time.

5. Setup and Wiring

Before connecting, ensure the power supply is off. Incorrect wiring can damage the module or connected devices.

5.1 Power Connection

  • Connect the DC 6-14V power supply to the DC+ and DC- terminals on the module. Ensure correct polarity (DC+ to positive, DC- to negative). The module includes reverse polarity protection.

5.2 Sensor Connection

  • Connect the photoresistor sensor probe to the SENSOR terminal. The module is designed to work with a photoresistor by default.

5.3 Load Connection (Relay Output)

The relay provides Normally Open (NO), Common (COM), and Normally Closed (NC) contacts. Refer to Figure 2 for the physical location of these terminals on the back of the module.

  • Normally Open (NO): Connect one end of your load (e.g., light, motor) to the NO terminal. Connect the other end of the load to your power source. The load will be ON when the relay is activated.
  • Common (COM): Connect the common line from your power source (e.g., positive or negative, depending on your load wiring) to the COM terminal.
  • Normally Closed (NC): Connect one end of your load to the NC terminal. Connect the other end of the load to your power source. The load will be ON when the relay is de-activated (off state).

Caution: Ensure the load current and voltage do not exceed the relay's maximum rating (220V AC 10A or 30V DC 10A).

6. Operation and Adjustment

The module's behavior is controlled by two potentiometers (trimmers) and the photoresistor sensor.

6.1 Brightness Detection Adjustment

  • Locate the potentiometer labeled for 'Brightness' or 'Sensitivity' (refer to Figure 3).
  • Turn the potentiometer clockwise to increase the sensitivity to light (relay activates at lower light levels).
  • Turn the potentiometer counter-clockwise to decrease sensitivity (relay activates at higher light levels).
  • Adjust this to set the ambient light threshold at which the relay should switch. For example, to turn on lights automatically at dusk, adjust until the relay triggers at your desired low light level.

6.2 Delay Time Adjustment

  • Locate the potentiometer labeled for 'Time' or 'Delay' (refer to Figure 3).
  • This potentiometer adjusts the delay time for the relay's on-time and off-time, ranging from 1 to 190 seconds.
  • Turning the potentiometer clockwise typically increases the delay time, while counter-clockwise decreases it.
  • This feature helps prevent rapid switching due to momentary light fluctuations (e.g., car headlights passing by).

7. Maintenance

  • Keep the module clean and free from dust and moisture.
  • Avoid exposing the module to extreme temperatures outside its operating range (-40 to 85℃).
  • Ensure all connections are secure and free from corrosion.
  • The photoresistor sensor should be kept clean and unobstructed for accurate light detection.

8. Troubleshooting

  • Module not powering on: Check the DC 6-14V power supply connections and ensure correct polarity. Verify the power source is active.
  • Relay not switching:
    • Adjust the brightness detection potentiometer. The ambient light might not be crossing the set threshold.
    • Ensure the photoresistor sensor is properly connected and not obstructed.
    • Check the delay time potentiometer. A long delay might be preventing immediate switching.
  • Load not activating/deactivating: Verify the load wiring to the relay's NO/COM/NC terminals. Ensure the load's power source is connected correctly and the load itself is functional. Check that the load's voltage and current requirements are within the relay's specifications.
  • Erratic switching: Adjust the delay time potentiometer to a longer duration to filter out momentary light changes. Ensure the sensor is not exposed to flickering light sources.

9. User Tips

Based on user feedback, here are some helpful tips for using the FC-66 module:

  • When setting the brightness threshold, perform adjustments in the actual lighting conditions where the module will operate (e.g., at dusk for outdoor lighting).
  • Experiment with the delay time setting to find the optimal balance between responsiveness and stability for your specific application.
  • Consider placing the photoresistor sensor in a location that accurately reflects the ambient light you wish to monitor, away from direct artificial light sources that might interfere with its readings.

10. Warranty and Support

For specific warranty information, please refer to the seller's terms and conditions at the time of purchase. For additional technical support or inquiries, please contact the seller directly.

A user manual in PDF format may be available for download: Download User Manual (PDF)

© 2024 diymore. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.